K982529510(k) TraditionalCleared Sep 11, 199853-day reviewClass I21 CFR 862.1475Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Randox Laboratories, Ltd. · MRR System, Test, Low Density, Lipoprotein

Cleared on Sep 11, 1998 after a 53-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 1 later device descends from it. It has been recalled once.

Decided
Sep 11, 1998
Review
53 days
Class
Class I
Product code
MRR
Recalls
1
Predicates
0

1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2017: 1 descendant cleared1995200020052010201520202025
  1. This deviceK982529 Randox Direct LDL CholesterolRandox Laboratories, Ltd. · 1998
  2. Descendant · cites it directly · 0 of its ownK161691 Direct LDL Cholesterol (LDL)Randox Laboratories Limited · 2017

Most influential descendants

Showing 1 of 1 · See all
  • K161691Direct LDL Cholesterol (LDL)Randox Laboratories Limited · 2017 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K982529Randox Direct LDL CholesterolRandox Laboratories, Ltd.1998—
+1K161691Direct LDL Cholesterol (LDL)Randox Laboratories Limited2017—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201710
FIG. 1 — Lineage of K982529, 1998–2017Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MRR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MRR device

  1. #1 K241800 Atellica® CH HDL Cholesterol (HDLC)& Atellica®…score 8.0 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K161691Direct LDL Cholesterol (LDL)Randox Laboratories Limited20170

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jan 27, 2023Class IIZ-1268-2023Under Investigation by firmReagent Carryover from LDL Cholesterol Direct (DLDL), Total Protein II (TP), Triglycerides (Trig), and Triglycerides_2 (Trig_2) Impacting Magnesium (Mg) Results

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K161691 (Randox Laboratories Limited, 2017) has gone furthest, with 0 descendants of its own.

How does its category compare?

All MRR devices

MRR System, Test, Low Density, Lipoprotein: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MRR

1in 2024

2008: 12009: 22017: 12023: 12024: 1
2007high 2 (2009) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MRR

Too few MRR 510(k)s in any year since 2007 to give a median.

Recalls per year · MRR

1in 2025

2008: 22018: 12025: 1
2007high 2 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MRR

1in 2024

2011: 32017: 32018: 22020: 12021: 12022: 12023: 12024: 1
2007high 3 (2011) · low 0 (2007)2025

MAUDE reports naming product code MRR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20081—20
20092—00
20100—00
20110—03
20120—00
20130—00
20140—00
20150—00
20160—00
20171—03
20180—12
20190—00
20200—01
20210—01
20220—01
20231—01
20241—01
20250—10
20260—0—

What is it indicated for?

The Randox Laboratories Limited Direct LDL Cholesterol Test Kit is an in vifro diagnostic reagent for use in the quantitative determination of LDL Cholesterol in serum and plasma. The method, an elimination enzymatic assay, does not require any sample preparation.

Accurate measurement of LDL Cholesterol is of vital importance in therapies that focus on lipid reduction to prevent atherosclerosis or reduce its progress.

Suitably qualified laboratory personnel under appropriate laboratory conditions must use this Test Kit.

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K982529: Randox Direct LDL Cholesterol.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K982529

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026