510(k) · Cleared
ClearedBladdermanager Pci 5000 Model 1002
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Diagnostic Ultrasound Corp. · ITX Transducer, Ultrasonic, Diagnostic
Cleared on Jan 25, 1999 as substantially equivalent to K955840 (Diagnostic Ultrasound Corp., 1996) after a 186-day review. Its family tree reaches back 2 generations to 1992.
- Decided
- Jan 25, 1999
- Review
- 186 days
- Class
- Class II
- Product code
- ITX
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K915436 (1992). No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in ITX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new ITX device
- #1 K260114 Align® Cover and Pad Guidance Toolscore 13.6 · 6 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K955840 | Bladdermanager Pci 5000 / Bladderscan Bvi 5000Summary page 1…egally Marketed Predicate Devices The BladderManager PCI 5000 is substantially equivalent to Diagnostic Ultrasound Corporation’s previous model BladderManager PCI 5000 (K955840). B. Device Description The BladderManager PCI 5000 is a portable, battery powered ultrasound instrument designed for a patient… | 1996 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 7 years and passes through 1 company; a new generation was cleared every 4.2 years on median.
- None of the 2 ancestors has a recall.
- 1 other device also cites its predicate K955840.
How does its category compare?
All ITX devicesITX Transducer, Ultrasonic, Diagnostic: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · ITX
4in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · ITX
126in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · ITX
2in 2025
Class I (10 since 2007) Class II/III not classified
Adverse event reports per year · ITX
571in 2025
MAUDE reports naming product code ITX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 10 | 26 | 0 | 16 |
| 2008 | 12 | 73 | 4 | 39 |
| 2009 | 17 | 28 | 4 | 23 |
| 2010 | 10 | 42 | 4 | 30 |
| 2011 | 10 | 16 | 1 | 34 |
| 2012 | 7 | 25 | 1 | 29 |
| 2013 | 3 | 105 | 0 | 38 |
| 2014 | 4 | 41 | 1 | 43 |
| 2015 | 1 | — | 5 | 183 |
| 2016 | 4 | 151 | 0 | 269 |
| 2017 | 6 | 110 | 1 | 412 |
| 2018 | 2 | — | 15 | 130 |
| 2019 | 1 | — | 0 | 119 |
| 2020 | 3 | 120 | 3 | 116 |
| 2021 | 3 | 139 | 10 (10) | 146 |
| 2022 | 2 | — | 6 | 87 |
| 2023 | 6 | 213 | 1 | 138 |
| 2024 | 3 | 81 | 1 | 988 |
| 2025 | 4 | 126 | 2 | 571 |
| 2026 | 6 | 158 | 0 | — |
What is it indicated for?
The BladderManager® PCl 5000(+) is intended to project ultrasound energy through the lower abdomen of the non-pregnant in order to obtain an image of the bladder that is used to determine bladder volume non-invasively. This capability is provided in 2 fundamental modes; 1) hand held probe, aimed by user to obtain reading and 2) Automatically monitor bladder volume via a garment-held probe on non-mobile, supine patient. Patients and/or caregivers are alerted visually and/or audibly when the bladder volume exceeds a pre-programmed threshold.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K982568 · printed Nov 5, 2026
Cite this page
510(k) Report. “K982568: Bladdermanager Pci 5000 Model 1002.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K982568
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026