510(k) · Cleared
Recalled · Class II · 2017Caredop II
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Nicolet Biomedical · JAF Monitor, Ultrasonic, Nonfetal
Cleared on Aug 7, 1998 after a 25-day review. FDA’s file for it is a 510(k) statement, which names no predicate. It has been recalled 4 times.
- Decided
- Aug 7, 1998
- Review
- 25 days
- Class
- Class II
- Product code
- JAF
- Recalls
- 4
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JAF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JAF device
- #1 K242487 Laminar P1 (LDH-HW-001)score 10.3 · 7 generations · no Class I recall
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Jun 9, 2017 | Class II | Z-2727-2017 | Radiation Control for Health and Safety Act | Some of the Elite 2 and 3 Obstetric probes and 5 MHz Vascular Probes may exhibit excessive background noise that may mask the users ability to clearly hear heart rate and/or blood flow. |
| Jun 9, 2017 | Class II | Z-2726-2017 | Radiation Control for Health and Safety Act | Some of the Elite 2 and 3 Obstetric probes and 5 MHz Vascular Probes may exhibit excessive background noise that may mask the users ability to clearly hear heart rate and/or blood flow. |
| Jun 9, 2017 | Class II | Z-2728-2017 | Radiation Control for Health and Safety Act | Some of the Elite 2 and 3 Obstetric probes and 5 MHz Vascular Probes may exhibit excessive background noise that may mask the users ability to clearly hear heart rate and/or blood flow. |
| Jun 9, 2017 | Class II | Z-2729-2017 | Radiation Control for Health and Safety Act | Some of the Elite 2 and 3 Obstetric probes and 5 MHz Vascular Probes may exhibit excessive background noise that may mask the users ability to clearly hear heart rate and/or blood flow. |
No ancestor or descendant has a Class I recall.
How does its category compare?
All JAF devicesJAF Monitor, Ultrasonic, Nonfetal: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JAF
1in 2024
2026 to Oct 25, outlined.
Median 510(k) review, days · JAF
Too few JAF 510(k)s in any year since 2007 to give a median.
Recalls per year · JAF
No recall names JAF since 2007.
Adverse event reports per year · JAF
1in 2023
MAUDE reports naming product code JAF, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 0 |
| 2008 | 1 | — | 0 | 0 |
| 2009 | 2 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 1 |
| 2011 | 1 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 1 |
| 2013 | 0 | — | 0 | 2 |
| 2014 | 0 | — | 0 | 8 |
| 2015 | 1 | — | 0 | 7 |
| 2016 | 0 | — | 0 | 5 |
| 2017 | 0 | — | 0 | 44 |
| 2018 | 0 | — | 0 | 1 |
| 2019 | 0 | — | 0 | 2 |
| 2020 | 0 | — | 0 | 5 |
| 2021 | 0 | — | 0 | 1 |
| 2022 | 0 | — | 0 | 2 |
| 2023 | 0 | — | 0 | 1 |
| 2024 | 1 | — | 0 | 0 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
Monitoring of blood flow in veins and arteries to assist in the detection of vascular disease and detection of early fetal heartbeat Instrument used in doctor’s office, clinic or hospital, by use for on the order of a physician.
The device is for non-invasive use only.
The device is not to be used on or near non-intact skin.
The device is not to be used on or near the eyes.
The device is to be used by or on order-of a physician.
Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K982635 · printed Nov 6, 2026
Cite this page
510(k) Report. “K982635: Caredop II.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K982635
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)