510(k) Report

510(k) · Cleared

Cleared

Forte, Models CPS 400 Combo, CPS 200 Combo

K982830510(k) TraditionalCleared Nov 6, 199887-day reviewClass II21 CFR 890.5860

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Chattanooga Group, Inc. · IMG Stimulator, Ultrasound And Muscle, For Use In Applying Therapeutic Deep Heat

Cleared on Nov 6, 1998 after an 87-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 3 later devices descend from it.

Decided
Nov 6, 1998
Review
87 days
Class
Class II
Product code
IMG
Recalls
None
Predicates
0

3 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2010: 1 descendant cleared2016: 2 descendants cleared1995200020052010201520202025
  1. This deviceK982830 Forte, Models CPS 400 Combo, CPS 200 ComboChattanooga Group, Inc. · 1998
  2. Descendant · cites it directly · 2 of its ownK091615 Med ContourGeneral Project S.R.L. · 2010
  3. Descendant · 2 generations on · 0 of its ownK160075 Accent XLAlma Lasers, Inc. · 2016
  4. Descendant · 2 generations on · 0 of its ownK161502 MC1 PlusGeneral Project S.R.L. · 2016

Most influential descendants

Showing 3 of 3 · See all
  • K091615Med ContourGeneral Project S.R.L. · 2010 · cites it directly2descendants
  • K160075Accent XLAlma Lasers, Inc. · 2016 · 2 generations on0descendants
  • K161502MC1 PlusGeneral Project S.R.L. · 2016 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K982830Forte, Models CPS 400 Combo, CPS 200 ComboChattanooga Group, Inc.1998—
+1K091615Med ContourGeneral Project S.R.L.2010—
+2K160075Accent XLAlma Lasers, Inc.2016—
+2K161502MC1 PlusGeneral Project S.R.L.2016—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201010
201620
FIG. 1 — Lineage of K982830, 1998–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IMG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IMG device

  1. #1 K244041 Ultrasound Therapy Workstation (XMS-UET2)score 10.7 · 3 generations · no Class I recall
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (3)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K091615Med ContourGeneral Project S.R.L.20102

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K091615 (General Project S.R.L., 2010) has gone furthest, with 2 descendants of its own.

How does its category compare?

All IMG devices

IMG Stimulator, Ultrasound And Muscle, For Use In Applying Therapeutic Deep Heat: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · IMG

1in 2025

2007: 32010: 12011: 32012: 22015: 22016: 12025: 1
2007high 3 (2007) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IMG

226in 2011

2007: 110 days median2011: 226 days median
2007high 226 (2011) · low 110 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IMG

2in 2008

2008: 2
2007high 2 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · IMG

9in 2025

2008: 372009: 262010: 62011: 212012: 62013: 42014: 32015: 42016: 72017: 32019: 142020: 102021: 132022: 142023: 72024: 52025: 9
2007high 37 (2008) · low 0 (2007)2025

MAUDE reports naming product code IMG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007311000
20080—237
20090—026
20101—06
20113226021
20122—06
20130—04
20140—03
20152—04
20161—07
20170—03
20180—00
20190—014
20200—010
20210—013
20220—014
20230—07
20240—05
20251—09
20260—0—

What is it indicated for?

Ultrasound for use in applying deep heat can be used for treatment of selected medical conditions such as the relief of pain, muscle spasms and joint contractures. These conditions may be associated with adhesive capsulitis; bursitis with slight calcification, myositis and soft tissue injuries. The Forte CPS Combo, while using any of the applicators available for this device, can provide therapeutic deep heating between 40° and 45 °C in all of its…

Read the full statement (132 words)

Ultrasound for use in applying deep heat can be used for treatment of selected medical conditions such as the relief of pain, muscle spasms and joint contractures. These conditions may be associated with adhesive capsulitis; bursitis with slight calcification, myositis and soft tissue injuries. The Forte CPS Combo, while using any of the applicators available for this device, can provide therapeutic deep heating between 40° and 45 °C in all of its operating modes.

For VMS, Russian, & Monophasic Hi-Volt

- Relaxation of muscle spasms

Prevention or retardation of disuse atrophy

Increasing local circulation

Muscle re-education

Maintaining or increasing range of motion

Immediate postsurgical stimulation of calf muscles to prevent venous thrombosis

For Interferential, Microcurrent, and Premod

Symptomatic relief of chronic, intractable p

Management of pain associated with post-traumatic or post-operative conditions

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K982830: Forte, Models CPS 400 Combo, CPS 200 Combo.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K982830

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026