510(k) · Cleared
ClearedOti Modular Shoulder System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Osteoimplant Technology, Inc. · HSD Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented
Cleared on Oct 5, 1998 after a 49-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Oct 5, 1998
- Review
- 49 days
- Class
- Class II
- Product code
- HSD
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HSD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HSD device
- #1 K191433 AGILON® XO Shoulder Replacement Systemscore 13.8 · 16 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All HSD devicesHSD Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · HSD
1in 2024
2026 to Oct 25, outlined.
Median 510(k) review, days · HSD
145in 2016
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HSD
1in 2020
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HSD
757in 2025
MAUDE reports naming product code HSD, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 4 | 72 | 0 | 128 |
| 2008 | 3 | 92 | 2 | 259 |
| 2009 | 0 | — | 2 | 156 |
| 2010 | 0 | — | 0 | 225 |
| 2011 | 2 | — | 0 | 241 |
| 2012 | 2 | — | 0 | 254 |
| 2013 | 4 | 218 | 0 | 288 |
| 2014 | 1 | — | 0 | 434 |
| 2015 | 0 | — | 0 | 574 |
| 2016 | 3 | 145 | 0 | 784 |
| 2017 | 0 | — | 3 | 985 |
| 2018 | 1 | — | 1 | 649 |
| 2019 | 0 | — | 0 | 830 |
| 2020 | 2 | — | 1 | 658 |
| 2021 | 0 | — | 0 | 573 |
| 2022 | 1 | — | 0 | 508 |
| 2023 | 0 | — | 0 | 586 |
| 2024 | 1 | — | 0 | 693 |
| 2025 | 0 | — | 0 | 757 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
Prosthetic replacement with the OTI Modular Shoulder System (Hemi humeral component) may be indicated to relieve severe pain or significant disability in degenerative, rheumatoid, or traumatic disease of the shoulder joint; non-union in humeral head fractures of long duration; avascular necrosis of the humeral hcad, traumatic fractures of the humerus and/ or other difficult clinical management problems.
Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K982886 · printed Nov 6, 2026
Cite this page
510(k) Report. “K982886: Oti Modular Shoulder System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K982886
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026