510(k) · Cleared
ClearedXenon Light Source, Models LS6180, LS6035
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Contec Medical Vision, Ltd. · GCT Light Source, Endoscope, Xenon Arc
Cleared on Sep 23, 1998 as substantially equivalent to K944821 (Richard Wolf Medical Instruments Corp., 1994) and 3 other predicates after a 30-day review. Its family tree reaches back 2 generations to 1994.
- Decided
- Sep 23, 1998
- Review
- 30 days
- Class
- Class II
- Product code
- GCT
- Recalls
- None
- Predicates
- 4
Its longest line of descent runs back 2 generations to K944821 (1994). 4 ancestors in all. No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K944821 | MODEL 5151 | Richard Wolf Medical Instruments Corp. | 1994 | — |
| −1 | K981804 | Xenon Light Source Model LS6000 | Contec Medical Vision, Ltd. | 1998 | — |
| 0 (this device) | K982962 | Xenon Light Source, Models LS6180, LS6035 | Contec Medical Vision, Ltd. | 1998 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1994 | 1 | 0 |
| 1995 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in GCT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (5)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K944821 | MODEL 5151Summary page 1…Xenon Light Source Model LS 6035/6180 is substantially equivalent to current and legally marketed devices. Examples are enclosed and include the Richard Wolf Model 5141(K944821), Model 5135 (K944607), the Karl Storz Model 201315-20 (K954561), the Linvatec Model 8430 (enclosed brochure information) and the… | 1994 |
| * | K944607 | Model 5135 Auto LP/FlashSummary page 1…del LS 6035/6180 is substantially equivalent to current and legally marketed devices. Examples are enclosed and include the Richard Wolf Model 5141(K944821), Model 5135 (K944607), the Karl Storz Model 201315-20 (K954561), the Linvatec Model 8430 (enclosed brochure information) and the CONTEC Model LS6000 (… | 1994 |
| * | K954561 | Xenon NoppvaSummary page 1…nt to current and legally marketed devices. Examples are enclosed and include the Richard Wolf Model 5141(K944821), Model 5135 (K944607), the Karl Storz Model 201315-20 (K954561), the Linvatec Model 8430 (enclosed brochure information) and the CONTEC Model LS6000 (K981804). Each Xenon Light Source is desi… | 1995 |
| * | K981804 | Xenon Light Source Model LS6000Summary page 1…Model 5141(K944821), Model 5135 (K944607), the Karl Storz Model 201315-20 (K954561), the Linvatec Model 8430 (enclosed brochure information) and the CONTEC Model LS6000 (K981804). Each Xenon Light Source is designed the same, meets the same specifications and its indication is the same. The only differenc… | 1998 |
| * | — | Linvatec Model 8430 Named without a submission number |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 4 years and passes through 2 companies; a new generation was cleared every 3.7 years on median.
- None of the 4 ancestors has a recall.
- 1 other device also cites its predicate K944821.
How does its category compare?
All GCT devicesGCT Light Source, Endoscope, Xenon Arc: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · GCT
1in 2010
2026 to Oct 25, outlined.
Median 510(k) review, days · GCT
Too few GCT 510(k)s in any year since 2007 to give a median.
Recalls per year · GCT
No recall names GCT since 2007.
Adverse event reports per year · GCT
347in 2025
MAUDE reports naming product code GCT, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 32 |
| 2008 | 1 | — | 0 | 29 |
| 2009 | 0 | — | 0 | 153 |
| 2010 | 1 | — | 0 | 21 |
| 2011 | 0 | — | 0 | 132 |
| 2012 | 0 | — | 0 | 36 |
| 2013 | 0 | — | 0 | 7 |
| 2014 | 0 | — | 0 | 11 |
| 2015 | 0 | — | 0 | 8 |
| 2016 | 0 | — | 0 | 15 |
| 2017 | 0 | — | 0 | 14 |
| 2018 | 0 | — | 0 | 20 |
| 2019 | 0 | — | 0 | 18 |
| 2020 | 0 | — | 0 | 114 |
| 2021 | 0 | — | 0 | 149 |
| 2022 | 0 | — | 0 | 158 |
| 2023 | 0 | — | 0 | 200 |
| 2024 | 0 | — | 0 | 296 |
| 2025 | 0 | — | 0 | 347 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The Xenon Light Source Model LS6035 is designed to supply light for endoscopic diagnostic observation and surgical procedures.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K982962 · printed Nov 6, 2026
Cite this page
510(k) Report. “K982962: Xenon Light Source, Models LS6180, LS6035.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K982962
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026