510(k) Report

510(k) · Cleared

Recalled · 2005

Wise (II) Image Management System

K983447510(k) SpecialCleared Oct 29, 199829-day reviewClass I21 CFR 892.2010Recalls 3

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sectra-Imtec AB · LMB Device, Digital Image Storage, Radiological

Cleared on Oct 29, 1998 as substantially equivalent to K971451 (O Tech, Inc., 1997) after a 29-day review. Its family tree reaches back 3 generations to 1993. 1 later device descends from it. It has been recalled 3 times.

Decided
Oct 29, 1998
Review
29 days
Class
Class I
Product code
LMB
Recalls
3
Predicates
1

Its longest line of descent runs back 3 generations to K922164 (1993). 1 later device descends from it, 1 citing it directly.

  1. Root · 3 generations backK922164 Raytel Digital Imaging SystemsOlicon Imaging Systems, Inc. · 1993
  2. 2 generations backK963395 Imageserver 2000 Picture Archiving SystemSectra-Imtec AB · 1996
  3. 1 generation backK971451 Wise Image Management SystemO Tech, Inc. · 1997
  4. This deviceK983447 Wise (II) Image Management SystemSectra-Imtec AB · 1998
  5. Descendant · cites it directly · 0 of its ownK992426 Raypax Web Clinical SystemSamsung Sds Co., Ltd. · 1999

Most influential descendants

Showing 1 of 1 · See all
  • K992426Raypax Web Clinical SystemSamsung Sds Co., Ltd. · 1999 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K922164Raytel Digital Imaging SystemsOlicon Imaging Systems, Inc.1993—
−2K963395Imageserver 2000 Picture Archiving SystemSectra-Imtec AB1996—
−1K971451Wise Image Management SystemO Tech, Inc.1997—
0 (this device)K983447Wise (II) Image Management SystemSectra-Imtec AB1998—
+1K992426Raypax Web Clinical SystemSamsung Sds Co., Ltd.1999—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199910
FIG. 1 — Lineage of K983447, 1993–1999Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LMB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K971451Wise Image Management System
Summary page 1
…tem Common Name: Digital Imaging System Classification Name: System, Digital Image Communication, Accessory Predicate Device: Applicant: Sectra Imtec AB 510(k) Number: K971451 Device: WISE Image Management System Device Description: WISE 1I is a system for managing digital radiological images. This incl…
O Tech, Inc.1997—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K992426Raypax Web Clinical SystemSamsung Sds Co., Ltd.19990

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Feb 16, 2005Not classifiedZ-0695-05OtherFailure to update correctly when re-transmitting an image from the modality.
Jun 27, 2003Not classifiedZ-1125-03OtherIf DICOM fields for body part, description or accession number are changed, change won't update on the EasyWeb client or hospital systems.
Feb 13, 2002Not classifiedZ-1223-03OtherPotential display of an incorrect body part description on patient images.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 5 years and passes through 3 companies; a new generation was cleared every 1.3 years on median.
  • None of the 3 ancestors has a recall.
  • Of its descendants, K992426 (Samsung Sds Co., Ltd., 1999) has gone furthest, with 0 descendants of its own.

How does its category compare?

All LMB devices

LMB Device, Digital Image Storage, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LMB

FDA has decided no LMB device since 2007.

Median 510(k) review, days · LMB

Too few LMB 510(k)s in any year since 2007 to give a median.

Recalls per year · LMB

1in 2013

2008: 12009: 52011: 22013: 1
2007high 5 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LMB

7in 2025

2007: 12008: 32009: 32010: 162011: 42012: 42013: 72014: 12016: 212017: 102018: 52019: 102020: 82021: 102023: 102024: 92025: 7
2007high 21 (2016) · low 0 (2015)2025

MAUDE reports naming product code LMB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—01
20080—13
20090—53
20100—016
20110—24
20120—04
20130—17
20140—01
20150—00
20160—021
20170—010
20180—05
20190—010
20200—08
20210—010
20220—00
20230—010
20240—09
20250—07
20260—0—

What is it indicated for?

The Sectra WISE Image Management System device is intended for the management and displaying of x-ray images, other radiological objects, and information.

It can manage images from different modalities, single and multiple file servers, and interfaces to various Radiological Information Systems (RIS), image storage and printing devices using DICOM or similar interface standards.

Typical users of this system are trained professionals, including but not limited to physicians, radiologists, nurses, medical technicians, and assistants.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K983447: Wise (II) Image Management System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K983447

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026