510(k) · Cleared
ClearedUni-Flex Resin
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Trans-Atlantic Dental · EBI Resin, Denture, Relining, Repairing, Rebasing
Cleared on Apr 13, 1999 after a 194-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Apr 13, 1999
- Review
- 194 days
- Class
- Class II
- Product code
- EBI
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in EBI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new EBI device
- #1 K250617 Apex Flexscore 18.3 · 1 generation · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All EBI devicesEBI Resin, Denture, Relining, Repairing, Rebasing: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · EBI
11in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · EBI
79in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · EBI
2in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · EBI
34in 2025
MAUDE reports naming product code EBI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 10 | 53 | 0 | 7 |
| 2008 | 6 | 124 | 0 | 2 |
| 2009 | 3 | 234 | 0 | 5 |
| 2010 | 4 | 95 | 0 | 4 |
| 2011 | 11 | 113 | 0 | 6 |
| 2012 | 3 | 85 | 0 | 9 |
| 2013 | 5 | 135 | 0 | 5 |
| 2014 | 5 | 102 | 0 | 9 |
| 2015 | 9 | 106 | 0 | 8 |
| 2016 | 7 | 147 | 0 | 9 |
| 2017 | 8 | 196 | 0 | 2 |
| 2018 | 5 | 158 | 2 | 2 |
| 2019 | 4 | 127 | 0 | 10 |
| 2020 | 6 | 283 | 0 | 8 |
| 2021 | 4 | 99 | 0 | 25 |
| 2022 | 11 | 154 | 2 | 2 |
| 2023 | 11 | 96 | 0 | 13 |
| 2024 | 9 | 90 | 0 | 1 |
| 2025 | 11 | 79 | 0 | 34 |
| 2026 | 7 | 87 | 0 | — |
What is it indicated for?
Uni-flex Resin is a flexible material that is used to produce the denture base in prosthetic partials. This material is packed and sealed in aluminum cariridges which are especially made to fit the Injection Mold System machine. To begin the production of a partial a cartridge is heated to 490'F. This allows the material becomes molten. The process of melting lasts ten minutes. After the material becomes molten the operator turns the handle of the…
Read the full statement (153 words)
Uni-flex Resin is a flexible material that is used to produce the denture base in prosthetic partials.
This material is packed and sealed in aluminum cariridges which are especially made to fit the Injection Mold System machine. To begin the production of a partial a cartridge is heated to 490'F. This allows the material becomes molten. The process of melting lasts ten minutes. After the material becomes molten the operator turns the handle of the Injection Mold System. This forces the material to inject into a previously prepared dental mold encased in an Injection Mold Flask. After the injection the cool down period lasts three minutes, the operator must remove the flask from the machine during this time. Then a twenty minute bench cool down period follows, only after the twenty minutes mold is removed from the flask. After this elapsed time the denture is now ready for finishing and high shine polish.
Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K983461 · printed Nov 6, 2026
Cite this page
510(k) Report. “K983461: Uni-Flex Resin.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K983461
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)