510(k) · Cleared
ClearedStar Temporary Wound Cover
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Osteogenics, Inc. · FTL Mesh, Surgical, Polymeric
Cleared on Nov 18, 1999 after a 398-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 19 later devices descend from it.
- Decided
- Nov 18, 1999
- Review
- 398 days
- Class
- Class II
- Product code
- FTL
- Recalls
- None
- Predicates
- 0
19 later devices descend from it, 2 citing it directly.
- This deviceK983753 Star Temporary Wound CoverOsteogenics, Inc. · 1999
- Descendant · cites it directly · 17 of its ownK022011 V.a.C. Abdominal DressingKinetic Concepts, Inc. · 2003 · Recalled
- Descendant · 2 generations on · 11 of its ownK100787 Renasys F/-AB Abdominal Wound Dressing KitSmith & Nephew, Inc. · 2010
- Descendant · 3 generations on · 10 of its ownK112784 Renasys AB Abominal Dressing KitSmith & Nephew, Inc. · 2011
- Descendant · 4 generations on · 5 of its ownK143133 RENASYS¿ EZ MAX Negative Pressure Wound Therapy Device, RENASYS¿ AB…Smith & Nephew, Inc. · 2015
- Descendant · 5 generations on · 3 of its ownK181822 RENASYS Touch; RENASYS Y-ConnectorSmith & Nephew Medical Limited · 2019
Showing 5 of 19 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 19 · See all- K022011V.a.C. Abdominal DressingKinetic Concepts, Inc. · 2003 · cites it directly17descendants
- K100787Renasys F/-AB Abdominal Wound Dressing KitSmith & Nephew, Inc. · 2010 · 2 generations on11descendants
- K112784Renasys AB Abominal Dressing KitSmith & Nephew, Inc. · 2011 · 3 generations on10descendants
- K143133RENASYS¿ EZ MAX Negative Pressure Wound Therapy Device, RENASYS¿ AB Abdominal Dressing…Smith & Nephew, Inc. · 2015 · 4 generations on5descendants
- K181822RENASYS Touch; RENASYS Y-ConnectorSmith & Nephew Medical Limited · 2019 · 5 generations on3descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K983753 | Star Temporary Wound Cover | Osteogenics, Inc. | 1999 | — |
| +1 | K022011 | V.a.C. Abdominal Dressing | Kinetic Concepts, Inc. | 2003 | 1 |
| +2 | K100787 | Renasys F/-AB Abdominal Wound Dressing Kit | Smith & Nephew, Inc. | 2010 | — |
| +3 | K112784 | Renasys AB Abominal Dressing Kit | Smith & Nephew, Inc. | 2011 | — |
| +4 | K143133 | RENASYS¿ EZ MAX Negative Pressure Wound Therapy Device, RENASYS¿ AB Abdominal… | Smith & Nephew, Inc. | 2015 | — |
| +5 | K181822 | RENASYS Touch; RENASYS Y-Connector | Smith & Nephew Medical Limited | 2019 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2003 | 1 | 0 |
| 2006 | 1 | 0 |
| 2009 | 3 | 0 |
| 2010 | 1 | 0 |
| 2011 | 1 | 0 |
| 2012 | 1 | 0 |
| 2013 | 1 | 0 |
| 2014 | 1 | 0 |
| 2015 | 1 | 0 |
| 2016 | 1 | 0 |
| 2019 | 4 | 0 |
| 2022 | 1 | 0 |
| 2024 | 1 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FTL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FTL device
- #1 K220091 Poly-Tape/Infinity-Lock Soft Tissue…score 16.8 · 14 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it? (19)
See all 192 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K022011 (Kinetic Concepts, Inc., 2003) has gone furthest, with 17 descendants of its own.
How does its category compare?
All FTL devicesFTL Mesh, Surgical, Polymeric: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · FTL
6in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FTL
30in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FTL
1in 2020
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · FTL
3,487in 2025
MAUDE reports naming product code FTL, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 20 | 92 | 2 | 1,737 |
| 2008 | 23 | 114 | 1 | 1,569 |
| 2009 | 15 | 97 | 1 | 1,906 |
| 2010 | 18 | 132 | 12 | 2,175 |
| 2011 | 15 | 90 | 8 | 3,608 |
| 2012 | 12 | 213 | 2 | 14,700 |
| 2013 | 8 | 90 | 1 | 26,519 |
| 2014 | 11 | 70 | 3 | 2,683 |
| 2015 | 12 | 121 | 0 | 2,526 |
| 2016 | 3 | 186 | 0 | 2,417 |
| 2017 | 6 | 132 | 1 | 3,947 |
| 2018 | 12 | 105 | 1 | 11,893 |
| 2019 | 4 | 99 | 0 | 21,724 |
| 2020 | 5 | 138 | 1 | 18,819 |
| 2021 | 2 | — | 0 | 16,284 |
| 2022 | 6 | 195 | 0 | 11,439 |
| 2023 | 4 | 29 | 0 | 8,025 |
| 2024 | 2 | — | 0 | 8,565 |
| 2025 | 6 | 30 | 0 | 3,487 |
| 2026 | 2 | — | 0 | — |
What is it indicated for?
For temporary bridging of abdominal wall openings where primary closure is not possible
and or repeat abdominal entries are necessary.
Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K983753 · printed Nov 4, 2026
Cite this page
510(k) Report. “K983753: Star Temporary Wound Cover.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K983753
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026