510(k) · Cleared
ClearedField Effects Mri System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Intermagnetics General Corp. · LNH System, Nuclear Magnetic Resonance Imaging
Cleared on Jan 7, 1999 as substantially equivalent to K963953 (Imig-Mri Systems, LLC, 1996) and 1 other predicate after a 65-day review. Its family tree reaches back 1 generation to 1994.
- Decided
- Jan 7, 1999
- Review
- 65 days
- Class
- Class II
- Product code
- LNH
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 1 generation to K943799 (1994). 2 ancestors in all. No later device cites it as a predicate yet.
- Root · 1 generation backK943799 Version 5 Operating System SoftwareHitachi Medical Systems America, Inc. · 1994
- This deviceK983902 Field Effects Mri SystemIntermagnetics General Corp. · 1999
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K943799 | Version 5 Operating System Software | Hitachi Medical Systems America, Inc. | 1994 | — |
| 0 (this device) | K983902 | Field Effects Mri System | Intermagnetics General Corp. | 1999 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1996 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LNH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LNH device
- #1 K213693 MAGNETOM Vida with syngo MR XA50Ascore 23.0 · 18 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K963953 | Imig-MriSummary page 2…vice Product Nomenclature: System, Nuclear Magnetic Resonance Imaging Product Code(s): QOLNH Trade/Proprietary Name: Field Effects MRI Predicate Device(s): IMIG-MRI. K963953 Hitachi MRP-5000 with Version 5.0 Operatfing System Software, K943799 DEVICE DESCRIPTION: FUNCTION Identical to the IMIG-MRI 51… | 1996 |
| * | K943799 | Version 5 Operating System SoftwareSummary page 2…g Product Code(s): QOLNH Trade/Proprietary Name: Field Effects MRI Predicate Device(s): IMIG-MRI. K963953 Hitachi MRP-5000 with Version 5.0 Operatfing System Software, K943799 DEVICE DESCRIPTION: FUNCTION Identical to the IMIG-MRI 510(k) K963953. The original IMIG-MRI system was renamed as TREX MRl in… | 1994 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- None of the 2 ancestors has a recall.
- 1 other device also cites its predicate K963953.
How does its category compare?
All LNH devicesLNH System, Nuclear Magnetic Resonance Imaging: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · LNH
26in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LNH
122in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LNH
8in 2025
Class I (8 since 2007) Class II/III not classified
Adverse event reports per year · LNH
1,263in 2025
MAUDE reports naming product code LNH, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 12 | 35 | 25 | 114 |
| 2008 | 19 | 53 | 12 | 167 |
| 2009 | 17 | 70 | 7 | 194 |
| 2010 | 12 | 94 | 17 | 165 |
| 2011 | 16 | 81 | 11 | 182 |
| 2012 | 22 | 89 | 5 | 170 |
| 2013 | 19 | 108 | 2 | 107 |
| 2014 | 17 | 108 | 13 | 119 |
| 2015 | 19 | 140 | 12 (2) | 113 |
| 2016 | 20 | 108 | 1 | 135 |
| 2017 | 18 | 98 | 0 | 121 |
| 2018 | 29 | 128 | 71 | 158 |
| 2019 | 26 | 62 | 5 | 158 |
| 2020 | 32 | 121 | 4 | 98 |
| 2021 | 27 | 87 | 41 | 84 |
| 2022 | 30 | 74 | 13 | 138 |
| 2023 | 30 | 124 | 10 (1) | 159 |
| 2024 | 26 | 104 | 4 | 281 |
| 2025 | 26 | 122 | 8 (5) | 1,263 |
| 2026 | 24 | 126 | 43 | — |
What is it indicated for?
The Field Effects MRI system produces cross-sectional images: Anatomical Region: General body anatomy, including head, spine, forso, and extremities Nucleus excited: 1H nuclei (Proton) Diagnostic uses: Images correspond to the distribution of 1H nuclei exhibiting nuclear magnetic resonance, with image intensity dependent upon NMR parameters, including - spin-lattice relaxation time (T1) - spin-spin relaxation time (12) - density of nuclei (p) - flow…
Read the full statement (142 words)
The Field Effects MRI system produces cross-sectional images:
Anatomical Region: General body anatomy, including head, spine, forso, and extremities
Nucleus excited: 1H nuclei (Proton)
Diagnostic uses: Images correspond to the distribution of 1H nuclei exhibiting nuclear magnetic resonance, with image intensity dependent upon NMR parameters, including
- spin-lattice relaxation time (T1)
- spin-spin relaxation time (12)
- density of nuclei (p)
- flow velocity
- chemical shift (3)
Clinical use: Images may be interpreted by a trained physician to yield information that can be useful in the determination of a diagnosis.
RF Coils:
Head - quadrature
Cervical Spine - quadrature
Lumbar Spine, Thoracic Spine, and Abdomen - quadrature
Knee - linear
Image Acquisition
Spin Echo
Gradient Echo (GE,RGE)
Fast Spin Echo (FSE)
Fast Dual Echo (FDE)
3D Fast Gradient Echo (3DGE, 3DRGE)
Inversion Recovery with Fast Spin Echo (FSE STIR, FSE FLAIR)
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K983902 · printed Nov 5, 2026
Cite this page
510(k) Report. “K983902: Field Effects Mri System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K983902
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026