510(k) Report

510(k) · Cleared

Cleared

Immulite Troponin I, Model LKTI1 and LKT15

K983972510(k) TraditionalCleared Dec 7, 199828-day reviewClass II21 CFR 862.1215

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Diagnostic Products Corp. · MMI Immunoassay Method, Troponin Subunit

Cleared on Dec 7, 1998 as substantially equivalent to K951890 (Dade Intl., Inc., 1995) after a 28-day review. Its family tree reaches back 1 generation to 1995.

Decided
Dec 7, 1998
Review
28 days
Class
Class II
Product code
MMI
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K951890 (1995). No later device cites it as a predicate yet.

  1. Root · 1 generation backK951890 Stratus Cardiac Troponin-I Fluorometric Enzyme Immunmnoassay &…Dade Intl., Inc. · 1995
  2. This deviceK983972 Immulite Troponin I, Model LKTI1 and LKT15Diagnostic Products Corp. · 1998
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K951890Stratus Cardiac Troponin-I Fluorometric Enzyme Immunmnoassay & Stratus Cardiac…Dade Intl., Inc.1995—
0 (this device)K983972Immulite Troponin I, Model LKTI1 and LKT15Diagnostic Products Corp.1998—
FIG. 1 — Lineage of K983972, 1995–1998Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MMI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MMI device

  1. #1 K253051 i-STAT hs-TnI cartridge with the i-STAT…score 13.0 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K951890Stratus Cardiac Troponin-I Fluorometric Enzyme Immunmnoassay & Stratus Cardiac…
Summary page 1
…s Corporation 5700 West 96" Street Los Angeles, California 90045-5597 DPC’s Registration Number is 2017183 Stratus® Cardiac Troponin-I Fluorometric Enzyme Immunoassay (K951890) IMMULITE® Troponin I is a clinical device for use with the IMMULITE® Automated Immunoassay Analyzer. - A R AT…
Dade Intl., Inc.1995—

Also cleared against K951890: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 1 other device also cites its predicate K951890.

How does its category compare?

All MMI devices

MMI Immunoassay Method, Troponin Subunit: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MMI

4in 2025

2007: 32008: 12009: 12010: 22011: 12013: 22017: 12018: 42019: 32021: 12022: 12023: 32024: 22025: 42026 (partial year): 1
2007high 4 (2018) · low 0 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MMI

266in 2025

2007: 190 days median2018: 344 days median2019: 88 days median2023: 270 days median2025: 266 days median
2007high 344 (2018) · low 88 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MMI

1in 2024

2007: 62008: 22009: 32010: 52011: 12012: 62014: 12015: 12019: 12020: 12021: 12024: 1
2007high 6 (2007) · low 0 (2013)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MMI

805in 2025

2007: 3522008: 8372009: 1,0102010: 1,3352011: 2,4062012: 1,8412013: 1,3942014: 1,1502015: 8312016: 4872017: 6182018: 4872019: 5212020: 3872021: 3562022: 5072023: 7482024: 9212025: 805
2007high 2,406 (2011) · low 352 (2007)2025

MAUDE reports naming product code MMI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200731906352
20081—2837
20091—31,010
20102—51,335
20111—12,406
20120—61,841
20132—01,394
20140—11,150
20150—1831
20160—0487
20171—0618
201843440487
20193881521
20200—1387
20211—1356
20221—0507
202332700748
20242—1921
202542660805
20261—0—

What is it indicated for?

IMMULITE® Troponin I is a solid-phase, two-site chemiluminescent enzyme immunometric assay for use with the IMMULITE Automated Analyzer and designed for the quantitative measurement of troponin I in serum, heparinized or citrate plasma. It is intended strictly for in vitro use as an aid in the diagnosis of acute myocardial infarction (AMI)

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K983972: Immulite Troponin I, Model LKTI1 and LKT15.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K983972

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026