Recalled · 2004Synchron Systems Enzyme Validator Set Levels 1 and 2
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Beckman Coulter, Inc. · JIX Calibrator, Multi-Analyte Mixture
Cleared on Dec 23, 1998 after a 42-day review. The FDA summary names its predicate without a number. 1 later device descends from it. It has been recalled once.
- Decided
- Dec 23, 1998
- Review
- 42 days
- Class
- Class II
- Product code
- JIX
- Recalls
- 1
- Predicates
- 0
1 later device descends from it, 1 citing it directly.
- This deviceK984014 Synchron Systems Enzyme Validator Set Levels 1 and 2Beckman Coulter, Inc. · 1998
- Descendant · cites it directly · 0 of its ownK032287 Modification to Synchron Systems Enzyme Validator Set Levels 1 and 2Beckman Coulter, Inc. · 2003
Most influential descendants
Showing 1 of 1 · See all- K032287Modification to Synchron Systems Enzyme Validator Set Levels 1 and 2Beckman Coulter, Inc. · 2003 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K984014 | Synchron Systems Enzyme Validator Set Levels 1 and 2 | Beckman Coulter, Inc. | 1998 | — |
| +1 | K032287 | Modification to Synchron Systems Enzyme Validator Set Levels 1 and 2 | Beckman Coulter, Inc. | 2003 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2003 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JIX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | SYNCHRON® Systems Enzyme Validator Set Named without a submission number |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K032287 | Modification to Synchron Systems Enzyme Validator Set Levels 1 and 2 | 2003 | 0 |
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Jul 29, 2004 | Not classified | Z-1378-04 | Other | incorrect Calibration Acceptance Limits. |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K032287 (Beckman Coulter, Inc., 2003) has gone furthest, with 0 descendants of its own.
How does its category compare?
All JIX devicesJIX Calibrator, Multi-Analyte Mixture: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JIX
1in 2016
2026 to Oct 25, outlined.
Median 510(k) review, days · JIX
29in 2015
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JIX
7in 2023
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JIX
18in 2025
MAUDE reports naming product code JIX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 6 | 53 | 2 | 140 |
| 2008 | 5 | 69 | 3 | 173 |
| 2009 | 4 | 121 | 2 | 39 |
| 2010 | 5 | 100 | 1 | 0 |
| 2011 | 7 | 77 | 2 | 9 |
| 2012 | 2 | — | 1 | 3 |
| 2013 | 4 | 50 | 0 | 24 |
| 2014 | 1 | — | 1 | 35 |
| 2015 | 3 | 29 | 0 | 4 |
| 2016 | 1 | — | 1 | 6 |
| 2017 | 0 | — | 1 | 17 |
| 2018 | 0 | — | 1 | 16 |
| 2019 | 0 | — | 1 | 12 |
| 2020 | 0 | — | 2 | 22 |
| 2021 | 0 | — | 0 | 9 |
| 2022 | 0 | — | 0 | 11 |
| 2023 | 0 | — | 7 | 13 |
| 2024 | 0 | — | 0 | 15 |
| 2025 | 0 | — | 0 | 18 |
| 2026 | 0 | — | 1 | — |
What is it indicated for?
The SYNCHRON® Systems Enzyme Validator Set, in conjunction with specified enzyme assays on Beckman SYNCHRON Systems, is intended to provide points of reference in the measurement of selected human enzymes. Use of this product will result in assay values which are compatible with those from methods recommended by the International Federation of Clinical Chemistry (IFCC) and the German Society for Clinical Chemistry (Deutsche Gesellschaft fur Klinische Chemie (DGKCh). Lipase values for specific for the LIP chemistry on SYNCHRON Systems.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K984014 · printed Nov 4, 2026
Cite this page
510(k) Report. “K984014: Synchron Systems Enzyme Validator Set Levels 1 and 2.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K984014
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026