510(k) · Cleared
ClearedAnterior Cervical Plating System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
United States Surgical, A Division of Tyco Healthc · KWQ Appliance, Fixation, Spinal Intervertebral Body
Cleared on Dec 30, 1998 after a 26-day review. The summary cites one number, which could not be confirmed as its predicate (see the table below).
- Decided
- Dec 30, 1998
- Review
- 26 days
- Class
- Class II
- Product code
- KWQ
- Recalls
- None
- Predicates
- 1
The summary cites one number, which could not be confirmed as its predicate (see the table below).
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KWQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KWQ device
- #1 K233640 Segmental Plating System (SPS);IdentiTi SPS…score 21.9 · 31 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.
| Type | Number | Device | Decided |
|---|---|---|---|
| Kept off the family tree | K843523 | FDA’s K843523 is Empty Solution Transfer Container 1000 Our OCR of the scanned summary read K843523, FDA’s number for Empty Solution Transfer Container 1000 (Polymer Technology Corp.). Its FDA name has none of the distinctive words the summary uses for the device it names, “ALINE™ Anterior Cervical Plating System”. Kept off the family tree. Summary page 1…mber 1, 1998 Spinal Intervertebral Body Fixation Orthosis Cervical Bone Plate System ALINE™ Anterior Cervical Plating System ALINE™ Anterior Cervical Plating System (K843523) The ALINE™ Anterior Cervical Plating System is utilized to provide post-operative stabilization until fusion of the cervical sp… | 1984 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All KWQ devicesKWQ Appliance, Fixation, Spinal Intervertebral Body: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · KWQ
7in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · KWQ
64in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KWQ
1in 2018
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KWQ
248in 2025
MAUDE reports naming product code KWQ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 27 | 101 | 2 | 288 |
| 2008 | 32 | 70 | 33 | 348 |
| 2009 | 23 | 90 | 35 | 355 |
| 2010 | 23 | 104 | 2 | 691 |
| 2011 | 22 | 95 | 5 | 415 |
| 2012 | 26 | 90 | 7 | 544 |
| 2013 | 22 | 88 | 6 | 796 |
| 2014 | 17 | 124 | 0 | 546 |
| 2015 | 25 | 102 | 2 | 562 |
| 2016 | 15 | 121 | 9 | 502 |
| 2017 | 20 | 67 | 8 | 492 |
| 2018 | 22 | 95 | 1 | 341 |
| 2019 | 26 | 81 | 0 | 298 |
| 2020 | 26 | 55 | 0 | 400 |
| 2021 | 17 | 59 | 0 | 591 |
| 2022 | 18 | 85 | 0 | 392 |
| 2023 | 16 | 59 | 0 | 320 |
| 2024 | 17 | 64 | 0 | 419 |
| 2025 | 7 | 64 | 0 | 248 |
| 2026 | 10 | 76 | 0 | — |
What is it indicated for?
The ALINE™ Anterior Cervical Plating System is designed to provide temporary stability to the cervical spine during the development of a solid spinal fusion in patients with degenerative disc disease (DDD), trauma (including fractures) and tumors. DDD is defined as neck and/or arm pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies. The device is intended for anterior cervical intervertebral body screw fixation enly.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K984342 · printed Nov 6, 2026
Cite this page
510(k) Report. “K984342: Anterior Cervical Plating System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K984342
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026