510(k) · Cleared
ClearedDepuy Profile Femoral Hip with Porocoat
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
DePuy Orthopaedics, Inc. · LPH Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented
Cleared on Jan 28, 1999 as substantially equivalent to K934457 (Depuy, Inc., 1994) and 3 other predicates after a 44-day review. Its family tree reaches back 2 generations to 1993.
- Decided
- Jan 28, 1999
- Review
- 44 days
- Class
- Class II
- Product code
- LPH
- Recalls
- None
- Predicates
- 4
Its longest line of descent runs back 2 generations to K915787 (1993). 5 ancestors in all, the oldest K850055 (1985). No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K915787 | Stability Hip Stem with Porocoat | Depuy, Inc. | 1993 | — |
| −1 | K934457 | Stability Hip Stem with Porocoat | Depuy, Inc. | 1994 | — |
| 0 (this device) | K984459 | Depuy Profile Femoral Hip with Porocoat | DePuy Orthopaedics, Inc. | 1999 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1985 | 1 | 0 |
| 1987 | 1 | 0 |
| 1991 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LPH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LPH device
- #1 K233498 Stryker Orthopaedics Hip Systems Labeling Updatescore 24.3 · 20 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (4)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K934457 | Stability Hip Stem with PorocoatSummary page 1…88.3358 Hip joint metal/polymer semi-constrained porous coated uncemented prosthesis DEVICE CODE: 87LPH EQUIVALENT DEVICES: DePuy Stability Hip System with Porocoat® (K934457) (Uncemented, K934457) DePuy Profile® Femoral Hip Prosthesis with Porocoat® (Cemented, K872776) DePuy Hydroxyapatite Coated Pro… | 1994 |
| * | K872776 | Profile Femoral Hip Prosthesis W/PorocoatSummary page 1…E: 87LPH EQUIVALENT DEVICES: DePuy Stability Hip System with Porocoat® (K934457) (Uncemented, K934457) DePuy Profile® Femoral Hip Prosthesis with Porocoat® (Cemented, K872776) DePuy Hydroxyapatite Coated Profile® Hip Stem (Press-Fit, K910156) DePuy Profile® Femoral Hip (Press-Fit, K850055) DEVICE DES… | 1987 |
| * | K910156 | Hydroxyapatite Coated Profile (R) Hip StemSummary page 1…at® (K934457) (Uncemented, K934457) DePuy Profile® Femoral Hip Prosthesis with Porocoat® (Cemented, K872776) DePuy Hydroxyapatite Coated Profile® Hip Stem (Press-Fit, K910156) DePuy Profile® Femoral Hip (Press-Fit, K850055) DEVICE DESCRIPTION AND INTENDED USE: The DePuy Profile® Hip with Porocoat® pr… | 1991 |
| * | K850055 | Profile Femoral HipSummary page 1…le® Femoral Hip Prosthesis with Porocoat® (Cemented, K872776) DePuy Hydroxyapatite Coated Profile® Hip Stem (Press-Fit, K910156) DePuy Profile® Femoral Hip (Press-Fit, K850055) DEVICE DESCRIPTION AND INTENDED USE: The DePuy Profile® Hip with Porocoat® prosthesis is identical in design and materials to… | 1985 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 6 years and passes through 2 companies; a new generation was cleared every 4.6 years on median.
- None of the 5 ancestors has a recall.
- 3 other devices also cite its predicate K934457.
How does its category compare?
All LPH devicesLPH Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · LPH
12in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LPH
153in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LPH
4in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LPH
6,163in 2025
MAUDE reports naming product code LPH, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 10 | 116 | 16 | 509 |
| 2008 | 10 | 86 | 1 | 706 |
| 2009 | 3 | 112 | 2 | 1,156 |
| 2010 | 15 | 100 | 22 | 2,007 |
| 2011 | 16 | 110 | 26 | 3,320 |
| 2012 | 25 | 76 | 30 | 3,785 |
| 2013 | 11 | 135 | 9 | 5,002 |
| 2014 | 20 | 129 | 3 | 5,163 |
| 2015 | 18 | 111 | 1 | 5,830 |
| 2016 | 10 | 150 | 8 | 4,900 |
| 2017 | 12 | 121 | 14 | 5,312 |
| 2018 | 9 | 145 | 2 | 5,954 |
| 2019 | 22 | 164 | 8 | 7,130 |
| 2020 | 7 | 164 | 6 | 5,429 |
| 2021 | 8 | 410 | 4 | 5,978 |
| 2022 | 14 | 247 | 2 | 5,223 |
| 2023 | 10 | 111 | 2 | 5,345 |
| 2024 | 6 | 92 | 1 | 5,626 |
| 2025 | 12 | 153 | 4 | 6,163 |
| 2026 | 8 | 256 | 2 | — |
What is it indicated for?
The DePuy Profile Femoral Hip with Porocoat prosthesis is indicated for uncemented or cemented use as the femoral component in total hip arthroplasty (THA) for replacing the hip joint of a patient whose hip joint has been damaged by inflammatory or non-inflammatory degenerative joint disease, fracture or the failure of a previous arthroplasty.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K984459 · printed Nov 4, 2026
Cite this page
510(k) Report. “K984459: Depuy Profile Femoral Hip with Porocoat.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K984459
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026