510(k) Report

510(k) · Cleared

Recalled · 2010

Polymedic Upa Nerve Stimulation Needle; Polymedic Upc Nerve Stimulation Needle

K990100510(k) TraditionalCleared Aug 2, 2000576-day reviewClass II21 CFR 882.1350Recalls 19

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Te ME NA S.A.R.L. · GXZ Electrode, Needle

Cleared on Aug 2, 2000 after a 576-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 3 later devices descend from it. It has been recalled 19 times.

Decided
Aug 2, 2000
Review
576 days
Class
Class II
Product code
GXZ
Recalls
19
Predicates
0

3 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2008: 1 descendant cleared2010: 2 descendants cleared200020052010201520202025
  1. This deviceK990100 Polymedic Upa Nerve Stimulation Needle; Polymedic Upc Nerve…Te ME NA S.A.R.L. · 2000
  2. Descendant · cites it directly · 2 of its ownK080603 Hybrid Nerve Location Needle Coated and UncoatedTe ME NA Sas · 2008 · Recalled
  3. Descendant · 2 generations on · 1 of its ownK093209 Focus ( TM) Echogenic Nerve Stimulating NeedleCook, Inc. · 2010
  4. Descendant · 3 generations on · 0 of its ownK101728 Focus (TM) Echogenic Nerve Stimulating NeedleCook, Inc. · 2010

Most influential descendants

Showing 3 of 3 · See all
  • K080603Hybrid Nerve Location Needle Coated and UncoatedTe ME NA Sas · 2008 · cites it directly2descendants
  • K093209Focus ( TM) Echogenic Nerve Stimulating NeedleCook, Inc. · 2010 · 2 generations on1descendant
  • K101728Focus (TM) Echogenic Nerve Stimulating NeedleCook, Inc. · 2010 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K990100Polymedic Upa Nerve Stimulation Needle; Polymedic Upc Nerve Stimulation NeedleTe ME NA S.A.R.L.2000—
+1K080603Hybrid Nerve Location Needle Coated and UncoatedTe ME NA Sas20082
+2K093209Focus ( TM) Echogenic Nerve Stimulating NeedleCook, Inc.2010—
+3K101728Focus (TM) Echogenic Nerve Stimulating NeedleCook, Inc.2010—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200810
201020
FIG. 1 — Lineage of K990100, 2000–2010Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GXZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GXZ device

  1. #1 K231691 Phantom XL Insulated Dilatorsscore 10.4 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (3)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K080603Hybrid Nerve Location Needle Coated and UncoatedTe ME NA Sas20082

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Feb 1, 2010Not classifiedZ-2362-2010Process controlDefects include, but not limited to: Not sterile, not properly labeled, drugs and swabs may be ineffective, and catheter tips may break in patients.
Feb 1, 2010Not classifiedZ-2373-2010Process controlDefects include, but not limited to: Not sterile, not properly labeled, drugs and swabs may be ineffective, and catheter tips may break in patients.
Feb 1, 2010Not classifiedZ-2365-2010Process controlDefects include, but not limited to: Not sterile, not properly labeled, drugs and swabs may be ineffective, and catheter tips may break in patients.
Feb 1, 2010Not classifiedZ-2376-2010Process controlDefects include, but not limited to: Not sterile, not properly labeled, drugs and swabs may be ineffective, and catheter tips may break in patients.
Feb 1, 2010Not classifiedZ-2367-2010Process controlDefects include, but not limited to: Not sterile, not properly labeled, drugs and swabs may be ineffective, and catheter tips may break in patients.
Feb 1, 2010Not classifiedZ-2370-2010Process controlDefects include, but not limited to: Not sterile, not properly labeled, drugs and swabs may be ineffective, and catheter tips may break in patients.
Feb 1, 2010Not classifiedZ-2361-2010Process controlDefects include, but not limited to: Not sterile, not properly labeled, drugs and swabs may be ineffective, and catheter tips may break in patients.
Feb 1, 2010Not classifiedZ-2379-2010Process controlDefects include, but not limited to: Not sterile, not properly labeled, drugs and swabs may be ineffective, and catheter tips may break in patients.
Feb 1, 2010Not classifiedZ-2366-2010Process controlDefects include, but not limited to: Not sterile, not properly labeled, drugs and swabs may be ineffective, and catheter tips may break in patients.
Feb 1, 2010Not classifiedZ-2378-2010Process controlDefects include, but not limited to: Not sterile, not properly labeled, drugs and swabs may be ineffective, and catheter tips may break in patients.
Feb 1, 2010Not classifiedZ-2372-2010Process controlDefects include, but not limited to: Not sterile, not properly labeled, drugs and swabs may be ineffective, and catheter tips may break in patients.
Feb 1, 2010Not classifiedZ-2364-2010Process controlDefects include, but not limited to: Not sterile, not properly labeled, drugs and swabs may be ineffective, and catheter tips may break in patients.
Feb 1, 2010Not classifiedZ-2374-2010Process controlDefects include, but not limited to: Not sterile, not properly labeled, drugs and swabs may be ineffective, and catheter tips may break in patients.
Feb 1, 2010Not classifiedZ-2363-2010Process controlDefects include, but not limited to: Not sterile, not properly labeled, drugs and swabs may be ineffective, and catheter tips may break in patients.
Feb 1, 2010Not classifiedZ-2369-2010Process controlDefects include, but not limited to: Not sterile, not properly labeled, drugs and swabs may be ineffective, and catheter tips may break in patients.
Feb 1, 2010Not classifiedZ-2371-2010Process controlDefects include, but not limited to: Not sterile, not properly labeled, drugs and swabs may be ineffective, and catheter tips may break in patients.
Feb 1, 2010Not classifiedZ-2368-2010Process controlDefects include, but not limited to: Not sterile, not properly labeled, drugs and swabs may be ineffective, and catheter tips may break in patients.
Feb 1, 2010Not classifiedZ-2377-2010Process controlDefects include, but not limited to: Not sterile, not properly labeled, drugs and swabs may be ineffective, and catheter tips may break in patients.
Feb 1, 2010Not classifiedZ-2375-2010Process controlDefects include, but not limited to: Not sterile, not properly labeled, drugs and swabs may be ineffective, and catheter tips may break in patients.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K080603 (Te ME NA Sas, 2008) has gone furthest, with 2 descendants of its own.

How does its category compare?

All GXZ devices

GXZ Electrode, Needle: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GXZ

1in 2024

2007: 32008: 22010: 12011: 22012: 12013: 22014: 22016: 12019: 22020: 12023: 22024: 1
2007high 3 (2007) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GXZ

102in 2007

2007: 102 days median
2007high 102 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GXZ

1in 2021

2010: 192021: 1
2007high 19 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GXZ

75in 2025

2007: 22009: 22010: 42011: 42012: 122013: 62014: 82015: 122016: 112017: 62018: 92019: 142020: 72021: 92022: 182023: 212024: 582025: 75
2007high 75 (2025) · low 0 (2008)2025

MAUDE reports naming product code GXZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007310202
20082—00
20090—02
20101—194
20112—04
20121—012
20132—06
20142—08
20150—012
20161—011
20170—06
20180—09
20192—014
20201—07
20210—19
20220—018
20232—021
20241—058
20250—075
20260—0—

What is it indicated for?

The Polymedic UPA and UPC Nerve Stimulator Needles, and the Polyplex N and Polyplex C Nerve Stimulation needle kits are intended for use in regional anesthesia procedures, by anesthesiologists or other trained professionals, for the location of peripheral nerves when used with a nerve stimulator) and administration of anesthesia drugs.

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K990100: Polymedic Upa Nerve Stimulation Needle; Polymedic Upc Nerve Stimulation Needle.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K990100

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026