510(k) · Cleared
ClearedDisposable Ecg Monitoring Electrodes, Models 4520, 4535, 4570
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Maersk Medical A/S · DRX Electrode, Electrocardiograph
Cleared on Dec 6, 1999 as substantially equivalent to K950470 (Nikomed U.S.A., Inc., 1995) and 1 other predicate after a 327-day review. Its family tree reaches back 1 generation to 1995.
- Decided
- Dec 6, 1999
- Review
- 327 days
- Class
- Class II
- Product code
- DRX
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 1 generation to K950470 (1995). 2 ancestors in all. No later device cites it as a predicate yet.
- Root · 1 generation backK950470 Disposable Ecg Monitoring Electrode #4535 32X45MMNikomed U.S.A., Inc. · 1995
- This deviceK990111 Disposable Ecg Monitoring Electrodes, Models 4520, 4535, 4570Maersk Medical A/S · 1999
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K950470 | Disposable Ecg Monitoring Electrode #4535 32X45MM | Nikomed U.S.A., Inc. | 1995 | — |
| 0 (this device) | K990111 | Disposable Ecg Monitoring Electrodes, Models 4520, 4535, 4570 | Maersk Medical A/S | 1999 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1995 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DRX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K950470 | Disposable Ecg Monitoring Electrode #4535 32X45MMSummary page 1…G Monitoring Electrodes Common Name: ECG Electrode Classification Name: Electrocardiograph Electrode PREDICATE DEVICE Disposable ECG Monitoring Electrode Models 4535 (K950470) and 4570 (K950478); Nikomed USA, Inc. DEVICE DESCRIPTION Pregelled electrodes are of Ag/AgCl construction with a sensor elemen… | 1995 |
| * | K950478 | Disposable Ecg Monitoring Electrode #4570 38X60MMSummary page 1…odes Common Name: ECG Electrode Classification Name: Electrocardiograph Electrode PREDICATE DEVICE Disposable ECG Monitoring Electrode Models 4535 (K950470) and 4570 (K950478); Nikomed USA, Inc. DEVICE DESCRIPTION Pregelled electrodes are of Ag/AgCl construction with a sensor element area be- tween 10… | 1995 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- None of the 2 ancestors has a recall.
How does its category compare?
All DRX devicesDRX Electrode, Electrocardiograph: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DRX
1in 2017
2026 to Oct 25, outlined.
Median 510(k) review, days · DRX
78in 2010
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DRX
6in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DRX
250in 2025
MAUDE reports naming product code DRX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 147 | 0 | 47 |
| 2008 | 3 | 17 | 0 | 15 |
| 2009 | 7 | 89 | 0 | 36 |
| 2010 | 5 | 78 | 4 | 48 |
| 2011 | 0 | — | 0 | 80 |
| 2012 | 0 | — | 0 | 41 |
| 2013 | 1 | — | 0 | 70 |
| 2014 | 1 | — | 0 | 27 |
| 2015 | 0 | — | 1 | 58 |
| 2016 | 0 | — | 0 | 37 |
| 2017 | 1 | — | 0 | 55 |
| 2018 | 0 | — | 0 | 43 |
| 2019 | 0 | — | 0 | 50 |
| 2020 | 0 | — | 5 | 53 |
| 2021 | 0 | — | 1 | 55 |
| 2022 | 0 | — | 6 | 61 |
| 2023 | 0 | — | 0 | 113 |
| 2024 | 0 | — | 0 | 61 |
| 2025 | 0 | — | 0 | 250 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
Short-term (< 24 hrs) ECG monitoring of infants in operating room and emergency situations (Model 4570); short-term (< 24 hrs) ECG monitoring of infants and neonates in operating room and emergency situations (Model 4520); short-term (< 24 hrs) ECG monitoring of adults and infants under anesthesia (Model 4535).
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K990111 · printed Nov 4, 2026
Cite this page
510(k) Report. “K990111: Disposable Ecg Monitoring Electrodes, Models 4520, 4535, 4570.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K990111
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026