510(k) · Cleared
ClearedStackable Cage System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Depuy Motech Acromed · MQP Spinal Vertebral Body Replacement Device
Cleared on Sep 3, 1999 as substantially equivalent to K841189 (Orthopedic Equipment Co., Inc., 1984) after a 227-day review. Its family tree reaches back 1 generation to 1984. 2 of the 1,869 devices in its family, counting itself, have a Class I recall. 1,867 later devices descend from it.
- Decided
- Sep 3, 1999
- Review
- 227 days
- Class
- Class II
- Product code
- MQP
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K841189 (1984). 1,867 later devices descend from it, 21 citing it directly. 2 of the 1,869 devices in this family, counting this one, have a Class I recall.
- Root · 1 generation backK841189 Oec/Rezaian Spinal FixatorOrthopedic Equipment Co., Inc. · 1984
- This deviceK990148 Stackable Cage SystemDepuy Motech Acromed · 1999
- Descendant · cites it directly · 1,819 of its ownK003043 Surgical Titanium Mesh SystemDepuyacromed · 2001
- Descendant · cites it directly · 1,705 of its ownK022793 Tetris Spinal ImplantSignus Medical, LLC · 2003
- Descendant · 2 generations on · 1,702 of its ownK031757 Peek Tetris Spinal ImplantSignus Medical, LLC · 2003
- Descendant · cites it directly · 1,622 of its ownK020887 Ebi Ais Spine SystemEbi, L.P. · 2002
- Descendant · 2 generations on · 1,621 of its ownK040482 Ebi Esl Spine Spacer SystemEbi, L.P. · 2004
Showing 5 of 1,867 descendants. See all descendants
Descendants cleared per year
Class I recalls in this family
Most influential descendants
Showing 5 of 1,867 · See all- K003043Surgical Titanium Mesh SystemDepuyacromed · 2001 · cites it directly1,819descendants
- K022793Tetris Spinal ImplantSignus Medical, LLC · 2003 · cites it directly1,705descendants
- K031757Peek Tetris Spinal ImplantSignus Medical, LLC · 2003 · 2 generations on1,702descendants
- K020887Ebi Ais Spine SystemEbi, L.P. · 2002 · cites it directly1,622descendants
- K040482Ebi Esl Spine Spacer SystemEbi, L.P. · 2004 · 2 generations on1,621descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K841189 | Oec/Rezaian Spinal Fixator | Orthopedic Equipment Co., Inc. | 1984 | — |
| 0 (this device) | K990148 | Stackable Cage System | Depuy Motech Acromed | 1999 | — |
| +1 | K003043 | Surgical Titanium Mesh System | Depuyacromed | 2001 | — |
| +1 | K022793 | Tetris Spinal Implant | Signus Medical, LLC | 2003 | — |
| +2 | K031757 | Peek Tetris Spinal Implant | Signus Medical, LLC | 2003 | — |
| +1 | K020887 | Ebi Ais Spine System | Ebi, L.P. | 2002 | — |
| +2 | K040482 | Ebi Esl Spine Spacer System | Ebi, L.P. | 2004 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2001 | 2 | 0 |
| 2002 | 2 | 0 |
| 2003 | 7 | 0 |
| 2004 | 14 | 0 |
| 2005 | 23 | 1 |
| 2006 | 14 | 0 |
| 2007 | 15 | 0 |
| 2008 | 27 | 0 |
| 2009 | 21 | 0 |
| 2010 | 30 | 0 |
| 2011 | 70 | 0 |
| 2012 | 68 | 0 |
| 2013 | 84 | 0 |
| 2014 | 106 | 0 |
| 2015 | 98 | 0 |
| 2016 | 112 | 0 |
| 2017 | 136 | 0 |
| 2018 | 120 | 0 |
| 2019 | 124 | 0 |
| 2020 | 110 | 0 |
| 2021 | 107 | 1 |
| 2022 | 111 | 0 |
| 2023 | 142 | 0 |
| 2024 | 128 | 0 |
| 2025 | 102 | 0 |
| 2026 | 94 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MQP device
- #1 K261810 Vertiwedge® Intraosseous Systemscore 18.1 · 22 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K841189 | Oec/Rezaian Spinal FixatorSummary page 2…erformance of the device in patients with spine tumors. SUBSTANTIAL EQUIVALENCE.: The Stackable Cage System is substantially equivalent to the Rezaian Spinal Fixator (K841189). The claim of substantial equivalence is made solely for regulatory purposes and shall not be deemed to be an assertion of equiv… | 1984 |
What descends from it? (1,867)
See all 1,86721 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K003043 | Surgical Titanium Mesh System | 2001 | 1,819 |
| K022793 | Tetris Spinal Implant | 2003 | 1,705 |
| K020887 | Ebi Ais Spine System | 2002 | 1,622 |
| K003836 | Synthes Synex Spacer System | 2001 | 1,330 |
| K032064 | Theken Cpod/Lpod Vertebral Body Replacement System | 2004 | 1,280 |
| K023835 | Devex Mesh System | 2003 | 1,227 |
| K030833 | Depuy Acromed VBR System | 2003 | 1,224 |
| K031635 | Depuy Acromed VBR System | 2003 | 1,201 |
| K041722 | Modification to VBR Spinal System | 2004 | 1,150 |
| K041617 | Stalif TT | 2004 | 929 |
Has anything in its family been recalled? (2 Class I)
No FDA recall names this device.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
What does this lineage say?
How does its category compare?
All MQP devicesMQP Spinal Vertebral Body Replacement Device: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · MQP
4in 2024
2026 to Oct 25, outlined.
Median 510(k) review, days · MQP
187in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MQP
1in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MQP
168in 2025
MAUDE reports naming product code MQP, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 30 | 107 | 2 | 61 |
| 2008 | 17 | 47 | 0 | 76 |
| 2009 | 11 | 115 | 14 | 111 |
| 2010 | 6 | 174 | 2 | 166 |
| 2011 | 8 | 237 | 1 | 121 |
| 2012 | 7 | 82 | 2 | 141 |
| 2013 | 3 | 90 | 0 | 207 |
| 2014 | 5 | 125 | 0 | 216 |
| 2015 | 8 | 126 | 0 | 258 |
| 2016 | 0 | — | 0 | 129 |
| 2017 | 9 | 97 | 0 | 141 |
| 2018 | 6 | 152 | 0 | 130 |
| 2019 | 8 | 93 | 0 | 117 |
| 2020 | 3 | 103 | 15 | 157 |
| 2021 | 0 | — | 0 | 208 |
| 2022 | 1 | — | 1 | 137 |
| 2023 | 1 | — | 0 | 71 |
| 2024 | 4 | 187 | 0 | 98 |
| 2025 | 0 | — | 0 | 168 |
| 2026 | 3 | 102 | 0 | — |
What is it indicated for?
The Stackable Cage” System is indicated for use in the thoracolumbar spine (i.e., T1 to LS) to replace a diseased vertebral body resected or excised for the treatment of tumors, to achieve anterior decompression of the spinal cord and neural tissues, and to restore the height of a collapsed vertebral body. The Stackable Cage System is designed to restore the biomechanical integrity of the anterior, middle and posterior spinal column even in the absence…
Read the full statement (127 words)
The Stackable Cage” System is indicated for use in the thoracolumbar spine (i.e., T1 to
LS) to replace a diseased vertebral body resected or excised for the treatment of tumors,
to achieve anterior decompression of the spinal cord and neural tissues, and to restore the
height of a collapsed vertebral body.
The Stackable Cage System is designed to restore the biomechanical integrity of the
anterior, middle and posterior spinal column even in the absence of fusion for a prolonged
period.
The Stackable Cage system is intended for use with supplemental internal fixation. The
supplemental internal fixation systems that may be used with the Stackable Cage System
include DePuy AcroMed titanium plate or rod systems (e.g., Kaneda SR, University Plate,
M-2, ISOLA, VSP, Moss Miami, TiMX, and Profile).
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K990148 · printed Nov 6, 2026
Cite this page
510(k) Report. “K990148: Stackable Cage System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K990148
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026