510(k) · Cleared
Recalled · Class II · 2013T-Anastaflo
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Edwards Lifesciences Research Medical · DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
Cleared on Oct 1, 1999 as substantially equivalent to K972261 (Integra Neurocare, LLC, 1997) after a 234-day review. Its family tree reaches back 1 generation to 1997. 1 later device descends from it. It has been recalled once.
- Decided
- Oct 1, 1999
- Review
- 234 days
- Class
- Class II
- Product code
- DWF
- Recalls
- 1
- Predicates
- 1
Its longest line of descent runs back 1 generation to K972261 (1997). 1 later device descends from it, 1 citing it directly.
Most influential descendants
Showing 1 of 1 · See all- K032977JMS Bypass TubeJms North America Corp. · 2004 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K972261 | Rivetti-Levinson Instraluminal Shunt | Integra Neurocare, LLC | 1997 | — |
| 0 (this device) | K990396 | T-Anastaflo | Edwards Lifesciences Research Medical | 1999 | — |
| +1 | K032977 | JMS Bypass Tube | Jms North America Corp. | 2004 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2004 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DWF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DWF device
- #1 K251258 MC2™ Two-Stage Venous Cannula; MC2X™…score 14.6 · 8 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K972261 | Rivetti-Levinson Instraluminal ShuntSummary page 1…lmonary bypass vascular catheter, cannula, or tubing. C. Predicate Device Name: Rivetti-Levinson Intraluminal Shunt Manufacturer: Heyer-Schulte Neurocare 510(k) Number: K972261 SE Decision Date: 1997-09-15 D. Device Description The T-AnastaFioc is a sterile, single use, disposable shunt composed of two… | 1997 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K032977 | JMS Bypass Tube | 2004 | 0 |
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Jul 30, 2013 | Class II | Z-1963-2013 | Process control | Edwards Lifesciences is recalling certain lots of the Anastaflo intravascular Shunt due to concerns of excessive adhesive on the shunt body that may interfere with suturing of by-pass grafts. |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Its one ancestor has no recall.
- Of its descendants, K032977 (Jms North America Corp., 2004) has gone furthest, with 0 descendants of its own.
How does its category compare?
All DWF devicesDWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DWF
4in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DWF
89in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DWF
4in 2024
Class I (3 since 2007) Class II/III not classified
Adverse event reports per year · DWF
1,020in 2025
MAUDE reports naming product code DWF, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 25 | 121 |
| 2008 | 6 | 95 | 25 | 126 |
| 2009 | 8 | 148 | 21 | 99 |
| 2010 | 3 | 62 | 26 | 197 |
| 2011 | 5 | 85 | 13 | 212 |
| 2012 | 10 | 110 | 37 | 233 |
| 2013 | 9 | 110 | 14 (1) | 238 |
| 2014 | 14 | 110 | 6 | 325 |
| 2015 | 9 | 46 | 3 (1) | 218 |
| 2016 | 3 | 32 | 3 | 144 |
| 2017 | 5 | 127 | 2 (1) | 101 |
| 2018 | 5 | 30 | 10 | 118 |
| 2019 | 3 | 120 | 2 | 179 |
| 2020 | 3 | 30 | 0 | 142 |
| 2021 | 5 | 358 | 3 | 162 |
| 2022 | 2 | — | 0 | 276 |
| 2023 | 2 | — | 0 | 470 |
| 2024 | 3 | 29 | 4 | 401 |
| 2025 | 4 | 89 | 0 | 1,020 |
| 2026 | 8 | 81 | 20 | — |
What is it indicated for?
The T-AnastaFlo is indicated for use in preventing ischemia by the shunting and/or perfusion of blood or cardioplegic solution distal to the anastomosis site during the construction of coronary artery bypass grafts.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K990396 · printed Nov 4, 2026
Cite this page
510(k) Report. “K990396: T-Anastaflo.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K990396
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026