510(k) · Cleared
ClearedGlucometer Elite XL Blood Glucose Meter, Glucometer Elite Blood Glucose Test Systems
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Bayer Corp. · CGA Glucose Oxidase, Glucose
Cleared on Jul 9, 1999 after a 130-day review. The FDA summary names its predicate without a number.
- Decided
- Jul 9, 1999
- Review
- 130 days
- Class
- Class II
- Product code
- CGA
- Recalls
- None
- Predicates
- 0
The FDA summary names its predicate without a number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in CGA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new CGA device
- #1 K252488 ABL90 FLEX PLUS Systemscore 12.8 · 6 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | GLUCOMETER ENCORE® QA+ Blood Glucose Test System Named without a submission number |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All CGA devicesCGA Glucose Oxidase, Glucose: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · CGA
2in 2024
2026 to Oct 25, outlined.
Median 510(k) review, days · CGA
249in 2023
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · CGA
3in 2023
Class I (2 since 2007) Class II/III not classified
Adverse event reports per year · CGA
59in 2025
MAUDE reports naming product code CGA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 7 | 122 | 2 | 29 |
| 2008 | 6 | 56 | 2 | 37 |
| 2009 | 10 | 155 | 4 | 75 |
| 2010 | 8 | 122 | 6 | 172 |
| 2011 | 9 | 217 | 3 | 423 |
| 2012 | 10 | 123 | 0 | 233 |
| 2013 | 3 | 441 | 3 | 172 |
| 2014 | 5 | 265 | 2 | 122 |
| 2015 | 4 | 150 | 6 (2) | 155 |
| 2016 | 4 | 157 | 2 | 36 |
| 2017 | 2 | — | 0 | 92 |
| 2018 | 2 | — | 0 | 69 |
| 2019 | 2 | — | 1 | 116 |
| 2020 | 2 | — | 0 | 68 |
| 2021 | 1 | — | 0 | 48 |
| 2022 | 1 | — | 0 | 272 |
| 2023 | 4 | 249 | 3 | 1,141 |
| 2024 | 2 | — | 0 | 266 |
| 2025 | 0 | — | 0 | 59 |
| 2026 | 1 | — | 0 | — |
What is it indicated for?
The GLUCOMETER ELITE Blood Glucose Test Systems and the GLUCOMETER ELITE XL Blood Glucose Meter are over-the-counter (OTC) home testing systems for glucose in blood. These systems are for use by person with diabetes and by healthcare professionals in a home setting and in healthcare facilities. The frequent monitoring of blodd glucose is an adjunct to the care of persons with diabetes.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K990649 · printed Nov 6, 2026
Cite this page
510(k) Report. “K990649: Glucometer Elite XL Blood Glucose Meter, Glucometer Elite Blood Glucose Test Systems.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K990649
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026