510(k) · Cleared
ClearedSignadress Duoderm Dressing
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Convatec, A Division of E.R. Squibb & Sons · KGN Wound Dressing With Animal-Derived Material (S)
Cleared on May 18, 1999 after a 56-day review. The FDA summary names its predicate without a number.
- Decided
- May 18, 1999
- Review
- 56 days
- Class
- Class U
- Product code
- KGN
- Recalls
- None
- Predicates
- 0
The FDA summary names its predicate without a number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KGN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KGN device
- #1 K231325 Corplex P / Theracor P / Allacor Pscore 17.9 · 8 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | CombiDERM™ ACD™ Absorbent Cover Dressing Named without a submission number | |
| † | K962590 | Signaldress | 1996 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All KGN devicesKGN Wound Dressing With Animal-Derived Material (S): FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · KGN
15so far in 2026, the most since 2007
2026 to Oct 25, outlined.
Median 510(k) review, days · KGN
162in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KGN
3in 2018
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KGN
15in 2025
MAUDE reports naming product code KGN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 32 | 0 | 0 |
| 2008 | 6 | 87 | 0 | 1 |
| 2009 | 8 | 121 | 0 | 2 |
| 2010 | 4 | 175 | 0 | 3 |
| 2011 | 7 | 228 | 0 | 6 |
| 2012 | 8 | 123 | 0 | 4 |
| 2013 | 6 | 147 | 0 | 6 |
| 2014 | 5 | 188 | 0 | 12 |
| 2015 | 7 | 87 | 0 | 9 |
| 2016 | 4 | 164 | 0 | 6 |
| 2017 | 7 | 136 | 1 | 8 |
| 2018 | 6 | 148 | 3 | 15 |
| 2019 | 3 | 128 | 0 | 11 |
| 2020 | 5 | 279 | 0 | 17 |
| 2021 | 6 | 236 | 0 | 14 |
| 2022 | 12 | 246 | 0 | 13 |
| 2023 | 9 | 194 | 0 | 21 |
| 2024 | 13 | 83 | 0 | 15 |
| 2025 | 10 | 162 | 0 | 15 |
| 2026 | 15 | 174 | 0 | — |
What is it indicated for?
For Over-The-Counter use SignaDRESS™ DuoDERM® Dressing may be used on abrasions, lacerations, minor cuts, minor scalds and burns, and skin tears. Under the supervision of a health care professional, SignaDRESS may be used for wounds such as leg ulcers ( venous stasis ulcers, arterial ulcers and leg ulcers of mixed aetiology), pressure ulcers (Stage I-IV) and diabetic ulcers, surgical wounds (post-operative wounds, donor sites, dermatological excisions), and burns (first and second degree).
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K990964 · printed Nov 6, 2026
Cite this page
510(k) Report. “K990964: Signadress Duoderm Dressing.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K990964
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026