Microelectroencephalography Professional System 5000 (Eeg Pro System 5000)

K991077510(k) TraditionalCleared Jun 9, 199970-day reviewClass II21 CFR 882.1330

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Microrecording Systems Consultants, LLC · GZL Electrode, Depth

Cleared on Jun 9, 1999 after a 70-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 1 of the 22 devices in its family, counting itself, has a Class I recall. 21 later devices descend from it.

Decided
Jun 9, 1999
Review
70 days
Class
Class II
Product code
GZL
Recalls
None
Predicates
0

21 later devices descend from it, 4 citing it directly. 1 of the 22 devices in this family, counting this one, has a Class I recall.

Descendants, by year cleared 2001: 2 descendants cleared, 1 with a Class I recall12000: 1 descendant cleared2004: 4 descendants cleared2017: 3 descendants cleared2009: 1 descendant cleared2006: 1 descendant cleared2023: 2 descendants cleared2025: 1 descendant cleared2021: 3 descendants cleared2022: 2 descendants cleared2026: 1 descendant cleared1995200020052010201520202025
  1. This deviceK991077 Microelectroencephalography Professional System 5000 (Eeg Pro System…Microrecording Systems Consultants, LLC · 1999
  2. Descendant · cites it directly · 17 of its ownK991522 Microtargeting ElectrodeFHC, Inc. · 2000 · Recalled
  3. Descendant · cites it directly · 16 of its ownK033173 Micro Targeting ElectrodeFHC, Inc. · 2004
  4. Descendant · 2 generations on · 12 of its ownK041604 Macro-Micro Depth ElectrodeAd-Tech Medical Instrument Corp · 2004
  5. Descendant · 3 generations on · 11 of its ownK053358 Depth Electrode, Foramen Ovale Depth Electrodes, Wyler Sphenoidal…Ad-Tech Medical Instrument Corp · 2006
  6. Descendant · cites it directly · 6 of its ownK012850 Recording and Stimulating ElectrodeRadionics, A Division of Tyco Healthcare Group LP · 2001

Showing 5 of 21 descendants. See all descendants

Descendants cleared per year

2000: 12001: 22004: 42006: 12009: 12017: 32021: 32022: 22023: 22025: 12026: 1
2000high 4 (2004) · low 0 (2002)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 21 · See all
  • K991522Microtargeting ElectrodeFHC, Inc. · 2000 · cites it directly17descendants
  • K033173Micro Targeting ElectrodeFHC, Inc. · 2004 · cites it directly16descendants
  • K041604Macro-Micro Depth ElectrodeAd-Tech Medical Instrument Corp · 2004 · 2 generations on12descendants
  • K053358Depth Electrode, Foramen Ovale Depth Electrodes, Wyler Sphenoidal Depth ElectrodesAd-Tech Medical Instrument Corp · 2006 · 3 generations on11descendants
  • K012850Recording and Stimulating ElectrodeRadionics, A Division of Tyco Healthcare Group LP · 2001 · cites it directly6descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K991077Microelectroencephalography Professional System 5000 (Eeg Pro System 5000)Microrecording Systems Consultants, LLC1999—
+1K991522Microtargeting ElectrodeFHC, Inc.20003
+1K033173Micro Targeting ElectrodeFHC, Inc.2004—
+2K041604Macro-Micro Depth ElectrodeAd-Tech Medical Instrument Corp2004—
+3K053358Depth Electrode, Foramen Ovale Depth Electrodes, Wyler Sphenoidal Depth…Ad-Tech Medical Instrument Corp2006—
+1K012850Recording and Stimulating ElectrodeRadionics, A Division of Tyco Healthcare Group LP2001—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200010
200121
200440
200610
200910
201730
202130
202220
202320
202510
202610
FIG. 1 — Lineage of K991077, 1999–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GZL device

  1. #1 K253970 Wovyn Depth Electrodescore 13.3 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (21)

See all 21

4 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K991522Microtargeting ElectrodeFHC, Inc.200017
K033173Micro Targeting ElectrodeFHC, Inc.200416
K012850Recording and Stimulating ElectrodeRadionics, A Division of Tyco Healthcare Group LP20016
K011775Micro Targeting Drive System Class IFHC, Inc.20011

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K011775Micro Targeting Drive SystemFHC, Inc. · 2001 · Cites it directly · ◆ in the 2001 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • Of its descendants, K991522 (FHC, Inc., 2000) has gone furthest, with 17 descendants of its own.

How does its category compare?

All GZL devices

GZL Electrode, Depth: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GZL

2in 2025

2007: 32009: 12011: 12012: 12013: 12014: 12016: 22017: 42018: 32020: 12021: 32022: 32023: 32025: 22026 (partial year): 1
2007high 4 (2017) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GZL

206in 2023

2007: 166 days median2017: 222 days median2018: 58 days median2021: 262 days median2022: 90 days median2023: 206 days median
2007high 262 (2021) · low 58 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GZL

3in 2024

2008: 32009: 22014: 12021: 92024: 3
2007high 9 (2021) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GZL

12in 2025

2008: 82009: 52010: 62011: 42012: 82013: 252014: 72015: 142016: 92017: 32018: 22019: 132020: 242021: 132022: 102023: 302024: 162025: 12
2007high 30 (2023) · low 0 (2007)2025

MAUDE reports naming product code GZL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007316600
20080—38
20091—25
20100—06
20111—04
20121—08
20131—025
20141—17
20150—014
20162—09
2017422203
201835802
20190—013
20201—024
20213262913
2022390010
20233206030
20240—316
20252—012
20261—0—

What is it indicated for?

The intended use of our uEEG™ Pro System 5000 is for temporary recording of intracranial neural activity, temporary intracranial stimulation of neurons, and mapping of neural activity and evoked potentials. Our uEEG™ Pro System 5000 is intended to be used during neurosurgical procedures for an amount of time that is sufficient to obtain the necessary information. During recording procedures, the required time duration is between 30 minutes to several…

Read the full statement (161 words)

The intended use of our uEEG™ Pro System 5000 is for temporary recording of intracranial neural activity, temporary intracranial stimulation of neurons, and mapping of neural activity and evoked potentials.

Our uEEG™ Pro System 5000 is intended to be used during neurosurgical procedures for an amount of time that is sufficient to obtain the necessary information. During recording procedures, the required time duration is between 30 minutes to several hours. During this time, an electrode will be in continuous contact with tissue for no longer than about 30 minutes.

The uEEG™ Pro System 5000 is designed for use in operating rooms appropriate for functional neurosurgery. (Warning Labels are attached to machine indicating that it is not to be used in the presence of flammable anesthetics).

uEEG™ Pro System 5000 is indicated for use during intraoperative intracranial neurophysiological recording and stimulation during deep brain stimulation, epilepsy surgery, and other procedures where it is appropriate to perform intracranial depth or subdural electrode recordings.

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K991077: Microelectroencephalography Professional System 5000 (Eeg Pro System 5000).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K991077

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026