Ionosit Bond

K991172510(k) TraditionalCleared May 17, 199940-day reviewClass II21 CFR 872.3275

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Dmg Chemisch Pharmazeutische Fabrik GmbH · EMA Cement, Dental

Cleared on May 17, 1999 as substantially equivalent to K962065 (3M Company, 1996) and 1 other predicate after a 40-day review. Its family tree reaches back 2 generations to 1988.

Decided
May 17, 1999
Review
40 days
Class
Class II
Product code
EMA
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K882821 (1988). 3 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 1992: 1 other ancestorK882821 · Vitrabond Light Cure Glass Ionomer Liner · 3M Company · 1988K962065 · 3M Vitrebond Light Cure Glass Ionomer/Base · 3M Company · 19961985199019952000
Other ancestors, by generation 2 generations back: 1 other ancestor K962065 · 3M Vitrebond Light Cure Glass Ionomer/Base · 3M Company · 1996K882821 · Vitrabond Light Cure Glass Ionomer Liner · 3M Company · 19880
  1. Root · 2 generations backK882821 Vitrabond Light Cure Glass Ionomer Liner3M Company · 1988
  2. 1 generation backK962065 3M Vitrebond Light Cure Glass Ionomer/Base3M Company · 1996
  3. This deviceK991172 Ionosit BondDmg Chemisch Pharmazeutische Fabrik GmbH · 1999
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K882821Vitrabond Light Cure Glass Ionomer Liner3M Company1988—
−1K9620653M Vitrebond Light Cure Glass Ionomer/Base3M Company1996—
0 (this device)K991172Ionosit BondDmg Chemisch Pharmazeutische Fabrik GmbH1999—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199210
FIG. 1 — Lineage of K991172, 1988–1999Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in EMA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new EMA device

  1. #1 K254109 G-Cem Universalscore 15.0 · 13 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K9620653M Vitrebond Light Cure Glass Ionomer/Base
Summary page 1
…: The proposed DMG Ionosit Bond material is substantially equivalent to the Vitrebond material marketed by 3M Dental Products, which was cleared for marketing by FDA in K962065 and K882821. Product Description: lonosit Bowd is a light-cure, glass ionomer liner/base material which is supplied in the form…
3M Company1996—
*K882821Vitrabond Light Cure Glass Ionomer Liner
Summary page 1
…ed DMG Ionosit Bond material is substantially equivalent to the Vitrebond material marketed by 3M Dental Products, which was cleared for marketing by FDA in K962065 and K882821. Product Description: lonosit Bowd is a light-cure, glass ionomer liner/base material which is supplied in the form of a powder…
3M Company1988—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 11 years and passes through 2 companies; a new generation was cleared every 7.8 years on median.
  • None of the 3 ancestors has a recall.

How does its category compare?

All EMA devices

EMA Cement, Dental: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · EMA

10in 2025

2007: 62008: 132009: 102010: 142011: 82012: 102013: 122014: 42015: 92016: 102017: 32018: 32019: 72020: 82021: 42022: 72023: 22024: 32025: 102026 (partial year): 7
2007high 14 (2010) · low 2 (2023)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · EMA

106in 2025

2007: 48 days median2008: 71 days median2009: 86 days median2010: 86 days median2011: 79 days median2012: 128 days median2013: 178 days median2014: 174 days median2015: 134 days median2016: 182 days median2017: 141 days median2018: 237 days median2019: 127 days median2020: 164 days median2021: 184 days median2022: 245 days median2024: 59 days median2025: 106 days median2026 (partial year): 150 days median
2007high 245 (2022) · low 48 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · EMA

1in 2023

2008: 22009: 12010: 12011: 52023: 1
2007high 5 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · EMA

9in 2025

2007: 332008: 502009: 902010: 1062011: 2242012: 2492013: 3852014: 2072015: 852016: 162017: 132018: 42019: 122020: 52021: 82022: 32023: 62024: 52025: 9
2007high 385 (2013) · low 3 (2022)2025

MAUDE reports naming product code EMA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007648033
20081371250
20091086190
201014861106
20118795224
2012101280249
2013121780385
201441740207
20159134085
201610182016
20173141013
2018323704
20197127012
2020816405
2021418408
2022724503
20232—16
202435905
20251010609
202671500—

What is it indicated for?

Ionosit Bond is indicated for use in lining and basing applications under composite, amalgam, ceramic and metal restorations.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K991172: Ionosit Bond.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K991172

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026