Harvest Technologies, LLC · JQC Centrifuges (Micro, Ultra, Refrigerated) For Clinical Use

Cleared on May 28, 1999 after a 32-day review. The FDA summary names its predicate without a number. 7 later devices descend from it. It has been recalled 2 times.

Decided
May 28, 1999
Review
32 days
Class
Class I
Product code
JQC
Recalls
2
Predicates
0

7 later devices descend from it, 3 citing it directly.

Descendants, by year cleared 2003: 1 descendant cleared2006: 1 descendant cleared2002: 1 descendant cleared2004: 1 descendant cleared2026: 2 descendants cleared2008: 1 descendant cleared1995200020052010201520202025
  1. This deviceK991430 Smartprep Centrifuge SystemHarvest Technologies, LLC · 1999
  2. Descendant · cites it directly · 3 of its ownK052925 SMARTPREP2 Centrifuge SystemHarvest Technologies, Corp. · 2006 · Recalled
  3. Descendant · cites it directly · 1 of its ownK021902 Magellan Autologus Platelet Separator, MAG100, Magellan Autologous…Medtronic Vascular · 2002
  4. Descendant · 2 generations on · 0 of its ownK250518 SMART M-CELL Bone Marrow Concentration SystemMiracell Co., Ltd. · 2026
  5. Descendant · 2 generations on · 0 of its ownK250516 SMART M-CELL PRP Concentration SystemMiracell Co., Ltd. · 2026
  6. Descendant · 2 generations on · 0 of its ownK081345 Axp Platform Marrow Xpress System Model 8-5137, 8-5138, 8-5139…Thermogenesis Corp. · 2008

Showing 5 of 7 descendants. See all descendants

Descendants cleared per year

2002: 12003: 12004: 12006: 12008: 12026: 2
2002high 2 (2026) · low 0 (2005)2026

Most influential descendants

Showing 5 of 7 · See all
  • K052925SMARTPREP2 Centrifuge SystemHarvest Technologies, Corp. · 2006 · cites it directly3descendants
  • K021902Magellan Autologus Platelet Separator, MAG100, Magellan Autologous Platelet Separator…Medtronic Vascular · 2002 · cites it directly1descendant
  • K250518SMART M-CELL Bone Marrow Concentration SystemMiracell Co., Ltd. · 2026 · 2 generations on0descendants
  • K250516SMART M-CELL PRP Concentration SystemMiracell Co., Ltd. · 2026 · 2 generations on0descendants
  • K081345Axp Platform Marrow Xpress System Model 8-5137, 8-5138, 8-5139, 8-5140 (Primary)Thermogenesis Corp. · 2008 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K991430Smartprep Centrifuge SystemHarvest Technologies, LLC1999—
+1K052925SMARTPREP2 Centrifuge SystemHarvest Technologies, Corp.20062
+1K021902Magellan Autologus Platelet Separator, MAG100, Magellan Autologous Platelet…Medtronic Vascular2002—
+2K250518SMART M-CELL Bone Marrow Concentration SystemMiracell Co., Ltd.2026—
+2K250516SMART M-CELL PRP Concentration SystemMiracell Co., Ltd.2026—
+2K081345Axp Platform Marrow Xpress System Model 8-5137, 8-5138, 8-5139, 8-5140 (Primary)Thermogenesis Corp.2008—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200210
200310
200410
200610
200810
202620
FIG. 1 — Lineage of K991430, 1999–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JQC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Predicate Centrifuge
Named without a submission number
—

What descends from it? (7)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K052925SMARTPREP2 Centrifuge SystemHarvest Technologies, Corp.20063
K021902Magellan Autologus Platelet Separator, MAG100, Magellan Autologous Platelet Separator…Medtronic Vascular20021
K030340Autologel Process Centrifuge, Model B4360 (100-103, 100-129)Cytomedix20030

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Oct 20, 2017Class IIZ-0103-2018Process controlThe patient labels included in the BMAC system procedure packs, catalog numbers 51416 and 51423, are printed with an incorrect lot number, catalog number, and expiry date; the lot number on the procedure pack box label is correct. The…
Oct 20, 2017Class IIZ-0104-2018Process controlThe patient labels included in the BMAC system procedure packs, catalog numbers 51416 and 51423, are printed with an incorrect lot number, catalog number, and expiry date; the lot number on the procedure pack box label is correct. The…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K052925 (Harvest Technologies, Corp., 2006) has gone furthest, with 3 descendants of its own.

How does its category compare?

All JQC devices

JQC Centrifuges (Micro, Ultra, Refrigerated) For Clinical Use: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JQC

1in 2019

2007: 22008: 12010: 12019: 1
2007high 2 (2007) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JQC

Too few JQC 510(k)s in any year since 2007 to give a median.

Recalls per year · JQC

3in 2019

2009: 22010: 22011: 12014: 12017: 22019: 32026 (partial year): 2
2007high 3 (2019) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JQC

6in 2025

2007: 62008: 72009: 52010: 72011: 402012: 182013: 262014: 1122015: 1302016: 702017: 312018: 102019: 72020: 42021: 12022: 12023: 42024: 22025: 6
2007high 130 (2015) · low 1 (2021)2025

MAUDE reports naming product code JQC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—06
20081—07
20090—25
20101—27
20110—140
20120—018
20130—026
20140—1112
20150—0130
20160—070
20170—231
20180—010
20191—37
20200—04
20210—01
20220—01
20230—04
20240—02
20250—06
20260—2—

What is it indicated for?

The Harvest SmartPReP™ CENTRIFUGE SYSTEM is designed to be used in the clinical laboratory or intraoperatively at point-of-care for the safe and rapid preparation of platelet poor plasma and platelet concentrate from a small sample of blood.

The plasma and concentrated platelets produced can be used for diagnostic tests.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K991430: Smartprep Centrifuge System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K991430

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026