Siemens FIO2 Sensor

K991884510(k) TraditionalCleared Nov 3, 1999154-day reviewClass II21 CFR 868.1720

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Siemens Medical Solutions USA, Inc. · CCL Analyzer, Gas, Oxygen, Gaseous-Phase

Cleared on Nov 3, 1999 as substantially equivalent to K961644 (Minesafety Appliances Co., 1996) after a 154-day review. Its family tree reaches back 2 generations to 1983.

Decided
Nov 3, 1999
Review
154 days
Class
Class II
Product code
CCL
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K833326 (1983). No later device cites it as a predicate yet.

  1. Root · 2 generations backK833326 Mini OX Iii Oxygen MonitorCatalyst Research Corp. · 1983
  2. 1 generation backK961644 Miniox 3000 Oxygen MonitorMinesafety Appliances Co. · 1996
  3. This deviceK991884 Siemens FIO2 SensorSiemens Medical Solutions USA, Inc. · 1999
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K833326Mini OX Iii Oxygen MonitorCatalyst Research Corp.1983—
−1K961644Miniox 3000 Oxygen MonitorMinesafety Appliances Co.1996—
0 (this device)K991884Siemens FIO2 SensorSiemens Medical Solutions USA, Inc.1999—
FIG. 1 — Lineage of K991884, 1983–1999Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CCL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CCL device

  1. #1 K261389 PRO2 Elite Plus Oxygen Analyzer (PRO2PLUS-1)score 12.7 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K961644Miniox 3000 Oxygen Monitor
Summary page 1
…mber Number Analyzer, Gas, Oxygen, Gaseous-Phase 73CCL II 868.1720 3. Predicate Device Identification: Mine Safety Appliances Company MiniOX® 3000 Oxygen Monitor 510(k) K961644 4. Device Description: The FiO2 Sensor is an addition to the Siemens INFINITY patient monitoring series that measures the oxygen…
Minesafety Appliances Co.1996—

Also cleared against K961644: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 16 years and passes through 3 companies; a new generation was cleared every 12.7 years on median.
  • None of the 2 ancestors has a recall.
  • 1 other device also cites its predicate K961644.

How does its category compare?

All CCL devices

CCL Analyzer, Gas, Oxygen, Gaseous-Phase: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CCL

2in 2025

2007: 22008: 22011: 12013: 22016: 12018: 12022: 22023: 12025: 22026 (partial year): 1
2007high 2 (2007) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CCL

Too few CCL 510(k)s in any year since 2007 to give a median.

Recalls per year · CCL

1in 2009

2009: 1
2007high 1 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · CCL

2in 2025

2007: 12008: 22009: 22010: 52011: 42012: 52013: 32014: 82015: 52016: 12017: 22018: 12019: 12020: 12021: 32023: 42024: 42025: 2
2007high 8 (2014) · low 0 (2022)2025

MAUDE reports naming product code CCL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—01
20082—02
20090—12
20100—05
20111—04
20120—05
20132—03
20140—08
20150—05
20161—01
20170—02
20181—01
20190—01
20200—01
20210—03
20222—00
20231—04
20240—04
20252—02
20261—0—

What is it indicated for?

Siemens FiO2 sensor is indicated for use in an environment where patient care is provided by healthcare professionals, i.e. Physicians, Nurses, Technicians, when the professional determines that the device is required to monitor the oxygen level of ambient air in non-pressurized environments such as that found in infant incubators and oxygen hoods.

The Siemens FiO2 sensor is not intended for use in a MRI magnetic field.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K991884: Siemens FIO2 Sensor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K991884

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026