510(k) Report

510(k) · Cleared

Cleared

Idemsa Hemophan Hollow Fiber Dialyzers

K991908510(k) TraditionalCleared Apr 17, 2000315-day reviewClass II21 CFR 876.5820

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Idemsa · FJI Dialyzer, Capillary, Hollow Fiber

Cleared on Apr 17, 2000 as substantially equivalent to K982337 (Haidylena Medical Egypt, 1998) after a 315-day review. Its family tree reaches back 2 generations to 1987.

Decided
Apr 17, 2000
Review
315 days
Class
Class II
Product code
FJI
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K864831 (1987). No later device cites it as a predicate yet.

  1. Root · 2 generations backK864831 Cobe Centrysystem 145E,160E,175E,190E DialyzersCobe Laboratories, Inc. · 1987
  2. 1 generation backK982337 Cuprophan and Hemophan Hollow Fiber DialyzerHaidylena Medical Egypt · 1998
  3. This deviceK991908 Idemsa Hemophan Hollow Fiber DialyzersIdemsa · 2000
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K864831Cobe Centrysystem 145E,160E,175E,190E DialyzersCobe Laboratories, Inc.1987—
−1K982337Cuprophan and Hemophan Hollow Fiber DialyzerHaidylena Medical Egypt1998—
0 (this device)K991908Idemsa Hemophan Hollow Fiber DialyzersIdemsa2000—
FIG. 1 — Lineage of K991908, 1987–2000Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FJI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K982337Cuprophan and Hemophan Hollow Fiber Dialyzer
Summary page 1
…y equivalent to the Hemophan membranes utilized in the Haidylena Cuprophan and Hemophan Hollow Fiber dialyzers (cleared for marketing in the United States under 510(k) # K982337). The Hemophan membranes utilized in both IDEMSA Hemophan dialyzers and Haidylena Cuprophan and Hemophan Hollow Fiber dialyzers a…
Haidylena Medical Egypt1998—
*—Cobe CentrySystem 160E
Named without a submission number
—
*—Baxter CF25
Named without a submission number
—
*—Terumo Clirans T175
Named without a submission number
—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 13 years and passes through 3 companies; a new generation was cleared every 11.8 years on median.
  • None of the 2 ancestors has a recall.

How does its category compare?

All FJI devices

FJI Dialyzer, Capillary, Hollow Fiber: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FJI

1in 2019

2013: 12019: 1
2007high 1 (2013) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FJI

Too few FJI 510(k)s in any year since 2007 to give a median.

Recalls per year · FJI

1in 2025

2025: 1
2007high 1 (2025) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FJI

145in 2025

2007: 172008: 112009: 32010: 322011: 472012: 2112013: 5532014: 6332015: 5612016: 5622017: 1822018: 112019: 202020: 162021: 122022: 22023: 512024: 1522025: 145
2007high 633 (2014) · low 2 (2022)2025

MAUDE reports naming product code FJI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—017
20080—011
20090—03
20100—032
20110—047
20120—0211
20131—0553
20140—0633
20150—0561
20160—0562
20170—0182
20180—011
20191—020
20200—016
20210—012
20220—02
20230—051
20240—0152
20250—1145
20260—0—

What is it indicated for?

The IDEMSA Hemophan Dialyzer has been designed for use in hemodialysis and associated forms of treatment for chronic or acute kidney failure.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K991908: Idemsa Hemophan Hollow Fiber Dialyzers.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K991908

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026