510(k) Report

510(k) · Cleared

Cleared

MAMEX

K992037510(k) SpecialCleared Jul 30, 199944-day reviewClass II21 CFR 892.1710

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Del Medical Imaging Corp. · IZH System, X-Ray, Mammographic

Cleared on Jul 30, 1999 after a 44-day review. FDA’s file for it is a 510(k) statement, which names no predicate.

Decided
Jul 30, 1999
Review
44 days
Class
Class II
Product code
IZH
Recalls
None
Predicates
0

FDA’s file for it is a 510(k) statement, which names no predicate.

FIG. 1 — Lineage of K992037Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IZH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IZH device

  1. #1 K202294 Affirm Contrast Biopsyscore 1.0 · 4 generations · no Class I recall
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All IZH devices

IZH System, X-Ray, Mammographic: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · IZH

1in 2021

2007: 32008: 12010: 22011: 12012: 22013: 22015: 12016: 32019: 12020: 12021: 1
2007high 3 (2007) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IZH

64in 2016

2007: 30 days median2016: 64 days median
2007high 64 (2016) · low 30 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IZH

2in 2008

2008: 2
2007high 2 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · IZH

15in 2025

2007: 112008: 52009: 142010: 72011: 52012: 182013: 92014: 72015: 82016: 92017: 122018: 252019: 392020: 72021: 92022: 42023: 82024: 52025: 15
2007high 39 (2019) · low 4 (2022)2025

MAUDE reports naming product code IZH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007330011
20081—25
20090—014
20102—07
20111—05
20122—018
20132—09
20140—07
20151—08
201636409
20170—012
20180—025
20191—039
20201—07
20211—09
20220—04
20230—08
20240—05
20250—015
20260—0—

What is it indicated for?

The option intended to provide the operator with the capabilities of selecting Rhodium filtration for enhanced image quality.

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K992037: MAMEX.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K992037

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026