510(k) Report

510(k) · Cleared

Recalled · 2008

Urological Catheter

K992137510(k) TraditionalCleared Sep 3, 199971-day reviewClass II21 CFR 876.5130Recalls 5

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Apogee, Inc. · GBM Catheter, Urethral

Cleared on Sep 3, 1999 after a 71-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 1 later device descends from it. It has been recalled 5 times.

Decided
Sep 3, 1999
Review
71 days
Class
Class II
Product code
GBM
Recalls
5
Predicates
0

1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2016: 1 descendant cleared1995200020052010201520202025
  1. This deviceK992137 Urological CatheterApogee, Inc. · 1999
  2. Descendant · cites it directly · 0 of its ownK160795 United Urologics Intermittent CatheterRobling Medical · 2016

Most influential descendants

Showing 1 of 1 · See all
  • K160795United Urologics Intermittent CatheterRobling Medical · 2016 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K992137Urological CatheterApogee, Inc.1999—
+1K160795United Urologics Intermittent CatheterRobling Medical2016—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201610
FIG. 1 — Lineage of K992137, 1999–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GBM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GBM device

  1. #1 K241734 Wellead® Hydrophilic Intermittent Catheter…score 10.2 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K160795United Urologics Intermittent CatheterRobling Medical20160

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jul 17, 2008Not classifiedZ-2390-2008Packaging process controlDue to a package seal defect the catheter tip may have been inadvertently cut which could cause trauma to the urethra upon use. Also the sterility of the product could be compromised.
Jul 17, 2008Not classifiedZ-2394-2008Packaging process controlDue to a package seal defect the catheter tip may have been inadvertently cut which could cause trauma to the urethra upon use. Also the sterility of the product could be compromised.
Jul 17, 2008Not classifiedZ-2392-2008Packaging process controlDue to a package seal defect the catheter tip may have been inadvertently cut which could cause trauma to the urethra upon use. Also the sterility of the product could be compromised.
Jul 17, 2008Not classifiedZ-2391-2008Packaging process controlDue to a package seal defect the catheter tip may have been inadvertently cut which could cause trauma to the urethra upon use. Also the sterility of the product could be compromised.
Jul 17, 2008Not classifiedZ-2393-2008Packaging process controlDue to a package seal defect the catheter tip may have been inadvertently cut which could cause trauma to the urethra upon use. Also the sterility of the product could be compromised.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K160795 (Robling Medical, 2016) has gone furthest, with 0 descendants of its own.

How does its category compare?

All GBM devices

GBM Catheter, Urethral: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GBM

1in 2025

2007: 22009: 12011: 22012: 32014: 12015: 52016: 32017: 22018: 62019: 72020: 62022: 22025: 1
2007high 7 (2019) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GBM

230in 2020

2012: 139 days median2015: 76 days median2016: 112 days median2018: 93 days median2019: 121 days median2020: 230 days median
2007high 230 (2020) · low 76 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GBM

1in 2025

2008: 52011: 12023: 1, 1 Class I2025: 12026 (partial year): 1
2007high 5 (2008) · low 0 (2007)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · GBM

311in 2025

2007: 52008: 182009: 32010: 332011: 462012: 322013: 412014: 192015: 212016: 492017: 592018: 822019: 1482020: 1442021: 1022022: 2832023: 2022024: 4682025: 311
2007high 468 (2024) · low 3 (2009)2025

MAUDE reports naming product code GBM, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—05
20080—518
20091—03
20100—033
20112—146
20123139032
20130—041
20141—019
2015576021
20163112049
20172—059
2018693082
201971210148
202062300144
20210—0102
20222—0283
20230—1 (1)202
20240—0468
20251—1311
20260—1—

What is it indicated for?

The Apogee Medical, Inc. Urinary Catheter is intended to be used as a urinary incontinence device designed to drain urine from the bladder

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K992137: Urological Catheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K992137

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026