510(k) Report

510(k) · Cleared

Cleared

Arthrocare Controller, Arthrocare Cable, Footswitch, Powercord, Spine Wands, Orthowands, Arthrowands

K992581510(k) TraditionalCleared Dec 9, 1999129-day reviewClass II21 CFR 878.4400

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Arthrocare Corp. · GEI Electrosurgical, Cutting & Coagulation & Accessories

Cleared on Dec 9, 1999 as substantially equivalent to K943450 (Arthrocare Corp., 1995) and 3 other predicates after a 129-day review. Its family tree reaches back 5 generations to 1995. 23 later devices descend from it.

Decided
Dec 9, 1999
Review
129 days
Class
Class II
Product code
GEI
Recalls
None
Predicates
4

Its longest line of descent runs back 5 generations to K943450 (1995). 16 ancestors in all, the oldest K800617 (1980). 23 later devices descend from it, 5 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1998: 1 other ancestor1996: 4 other ancestors1995: 2 other ancestors1994: 1 other ancestor1992: 2 other ancestors1980: 1 other ancestor2001: 3 descendants cleared2010: 1 descendant cleared2004: 1 descendant cleared2006: 1 descendant cleared2005: 1 descendant cleared2012: 1 descendant cleared2015: 2 descendants cleared2018: 2 descendants cleared2021: 1 descendant cleared2017: 1 descendant cleared2025: 3 descendants cleared2020: 1 descendant cleared2019: 1 descendant cleared2023: 1 descendant cleared2022: 1 descendant cleared2024: 1 descendant cleared2026: 1 descendant clearedK943450 · Arthrocare Arthroscopic Electrosurgery System Model 970 · Arthrocare Corp. · 1995×2: 2 generations cleared close together, K961069 (1996), K962445 (1996) K964849 · Arthrocare Dermatologic Electrosurgery System · Arthrocare Corp. · 1997K973478 · Arthrocare Sinus Electrosurgery System · Arthrocare Corp. · 199819801990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors2 generations back: 6 other ancestors3 generations back: 3 other ancestors 1 generation forward: 5 descendants2 generations forward: 4 descendants3 generations forward: 4 descendants4 generations forward: 2 descendants5 generations forward: 3 descendants6 generations forward: 3 descendants7 generations forward: 2 descendants K973478 · Arthrocare Sinus Electrosurgery System · Arthrocare Corp. · 1998K964849 · Arthrocare Dermatologic Electrosurgery System · Arthrocare Corp. · 1997K962445 · Arthrocare Dental Electrosurgery System · Arthrocare Corp. · 1996K961069 · Arthrocare Urologic Multi-Electrode Electrosurgery System · Arthrocare Corp. · 1996K943450 · Arthrocare Arthroscopic Electrosurgery System Model 970 · Arthrocare Corp. · 1995−50+5
  1. Root · 5 generations backK943450 Arthrocare Arthroscopic Electrosurgery System Model 970Arthrocare Corp. · 1995
  2. 4 generations backK961069 Arthrocare Urologic Multi-Electrode Electrosurgery SystemArthrocare Corp. · 1996
  3. 3 generations backK962445 Arthrocare Dental Electrosurgery SystemArthrocare Corp. · 1996
  4. 2 generations backK964849 Arthrocare Dermatologic Electrosurgery SystemArthrocare Corp. · 1997
  5. 1 generation backK973478 Arthrocare Sinus Electrosurgery SystemArthrocare Corp. · 1998
  6. This deviceK992581 Arthrocare Controller, Arthrocare Cable, Footswitch, Powercord…Arthrocare Corp. · 1999
  7. Descendant · cites it directly · 11 of its ownK091310 Ablation Instrument, Model 1635; Ablation Multiplex Catheter, Model…Dfine, Inc. · 2010
  8. Descendant · 2 generations on · 9 of its ownK142480 OsteoCool V-2 RF Ablation SystemBaylis Medical Company, Inc. · 2015
  9. Descendant · 3 generations on · 8 of its ownK152057 OsteoCool V-3 RF Ablation SystemBaylis Medical Company, Inc. · 2015
  10. Descendant · 4 generations on · 7 of its ownK161949 OsteoCool V-3 RF Ablation SystemBaylis Medical Company, Inc. · 2017
  11. Descendant · cites it directly · 6 of its ownK033547 Vnus Vessel and Tissue Coagulation SystemVnus Medical Technologies, Inc. · 2004

Showing 5 of 23 descendants. See all descendants

Descendants cleared per year

2001: 32004: 12005: 12006: 12010: 12012: 12015: 22017: 12018: 22019: 12020: 12021: 12022: 12023: 12024: 12025: 32026: 1
2001high 3 (2001) · low 0 (2002)2026

Most influential descendants

Showing 5 of 23 · See all
  • K091310Ablation Instrument, Model 1635; Ablation Multiplex Catheter, Model 1682Dfine, Inc. · 2010 · cites it directly11descendants
  • K142480OsteoCool V-2 RF Ablation SystemBaylis Medical Company, Inc. · 2015 · 2 generations on9descendants
  • K152057OsteoCool V-3 RF Ablation SystemBaylis Medical Company, Inc. · 2015 · 3 generations on8descendants
  • K161949OsteoCool V-3 RF Ablation SystemBaylis Medical Company, Inc. · 2017 · 4 generations on7descendants
  • K033547Vnus Vessel and Tissue Coagulation SystemVnus Medical Technologies, Inc. · 2004 · cites it directly6descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K943450Arthrocare Arthroscopic Electrosurgery System Model 970Arthrocare Corp.1995—
−4K961069Arthrocare Urologic Multi-Electrode Electrosurgery SystemArthrocare Corp.1996—
−3K962445Arthrocare Dental Electrosurgery SystemArthrocare Corp.1996—
−2K964849Arthrocare Dermatologic Electrosurgery SystemArthrocare Corp.1997—
−1K973478Arthrocare Sinus Electrosurgery SystemArthrocare Corp.1998—
0 (this device)K992581Arthrocare Controller, Arthrocare Cable, Footswitch, Powercord, Spine Wands…Arthrocare Corp.1999—
+1K091310Ablation Instrument, Model 1635; Ablation Multiplex Catheter, Model 1682Dfine, Inc.2010—
+2K142480OsteoCool V-2 RF Ablation SystemBaylis Medical Company, Inc.2015—
+3K152057OsteoCool V-3 RF Ablation SystemBaylis Medical Company, Inc.2015—
+4K161949OsteoCool V-3 RF Ablation SystemBaylis Medical Company, Inc.2017—
+1K033547Vnus Vessel and Tissue Coagulation SystemVnus Medical Technologies, Inc.2004—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198010
199220
199410
199520
199640
199810

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200130
200410
200510
200610
201010
201210
201520
201710
201820
201910
202010
202110
202210
202310
202410
202530
202610
FIG. 1 — Lineage of K992581, 1995–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GEI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GEI device

  1. #1 K231790 The InMode System with the Morpheus8 Applicatorsscore 32.7 · 21 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K943450Arthrocare Arthroscopic Electrosurgery System Model 970
Summary page 1
…oCare Orthopedic Electrosurgery System Generic/Common Name: Electrosurgical Device and Accessories Predicate Devices ArthroCare Arthroscopic Electrosurgery System 970 K943450 ArthroCare Arthroscopic Electrosurgery System 980 (Model 2000) K963123 ArthroCare ENTec Surgery System K973478 Ellman Surgitron K…
Arthrocare Corp.1995—
*K963123Arthrocare Arthroscopic Eletrosurgery System (Model 980)
Summary page 1
…gical Device and Accessories Predicate Devices ArthroCare Arthroscopic Electrosurgery System 970 K943450 ArthroCare Arthroscopic Electrosurgery System 980 (Model 2000) K963123 ArthroCare ENTec Surgery System K973478 Ellman Surgitron K980170 Intended Use The ArthroCare Orthopedic Electrosurgery System is…
Arthrocare Corp.1996—
*K973478Arthrocare Sinus Electrosurgery System
Summary page 1
…Devices ArthroCare Arthroscopic Electrosurgery System 970 K943450 ArthroCare Arthroscopic Electrosurgery System 980 (Model 2000) K963123 ArthroCare ENTec Surgery System K973478 Ellman Surgitron K980170 Intended Use The ArthroCare Orthopedic Electrosurgery System is indicated for resection, ablation, and…
Arthrocare Corp.1998—
*K980170Surgitron
Summary page 1
…oscopic Electrosurgery System 970 K943450 ArthroCare Arthroscopic Electrosurgery System 980 (Model 2000) K963123 ArthroCare ENTec Surgery System K973478 Ellman Surgitron K980170 Intended Use The ArthroCare Orthopedic Electrosurgery System is indicated for resection, ablation, and coagulation of soft tissu…
Ellman Intl., Inc.1998—

Also cleared against K943450: 10 other devices →

What descends from it? (23)

See all 23

5 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K091310Ablation Instrument, Model 1635; Ablation Multiplex Catheter, Model 1682Dfine, Inc.201011
K033547Vnus Vessel and Tissue Coagulation SystemVnus Medical Technologies, Inc.20046
K012631Reprocessed Soft Tissue AblatorsAlliance Medical Corp.20011
K012679Reprocessed RF Arthroscopy ProbesSterilmed, Inc.20010
K012129Ortho Development Orion-I Emf SystemOrtho Development Corp.20010

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 4 years and passes through 1 company; a new generation was cleared every 9 months on median.
  • 1 of the 16 ancestors has a recall of any class.
  • Of its descendants, K091310 (Dfine, Inc., 2010) has gone furthest, with 11 descendants of its own.
  • 10 other devices also cite its predicate K943450.

How does its category compare?

All GEI devices

GEI Electrosurgical, Cutting & Coagulation & Accessories: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GEI

52in 2025

2007: 502008: 612009: 422010: 462011: 352012: 392013: 482014: 492015: 472016: 642017: 522018: 472019: 482020: 592021: 462022: 552023: 652024: 592025: 522026 (partial year): 43
2007high 65 (2023) · low 35 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GEI

113in 2025

2007: 51 days median2008: 71 days median2009: 130 days median2010: 109 days median2011: 135 days median2012: 133 days median2013: 136 days median2014: 103 days median2015: 123 days median2016: 108 days median2017: 72 days median2018: 93 days median2019: 93 days median2020: 105 days median2021: 146 days median2022: 150 days median2023: 104 days median2024: 125 days median2025: 113 days median2026 (partial year): 183 days median
2007high 183 (2026) · low 51 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GEI

4in 2025

2007: 212008: 192009: 272010: 512011: 322012: 302013: 132014: 32015: 42016: 32017: 22018: 62019: 52020: 12021: 62022: 492023: 27, 4 Class I2024: 22, 10 Class I2025: 42026 (partial year): 8
2007high 51 (2010) · low 1 (2020)2026

Class I (14 since 2007) Class II/III not classified

Adverse event reports per year · GEI

7,592in 2025

2007: 2,7952008: 2,5562009: 3,5912010: 3,3772011: 4,4632012: 5,2162013: 4,8972014: 4,9082015: 4,9362016: 5,6162017: 6,0732018: 6,5452019: 7,0672020: 6,4902021: 6,3542022: 6,1032023: 7,1762024: 7,8972025: 7,592
2007high 7,897 (2024) · low 2,556 (2008)2025

MAUDE reports naming product code GEI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20075051212,795
20086171192,556
200942130273,591
201046109513,377
201135135324,463
201239133305,216
201348136134,897
20144910334,908
20154712344,936
20166410835,616
2017527226,073
2018479366,545
2019489357,067
20205910516,490
20214614666,354
202255150496,103
20236510427 (4)7,176
20245912522 (10)7,897
20255211347,592
2026431838—

What is it indicated for?

The ArthroCare Orthopedic Electrosurgery System is indicated for resection, ablation, and coagulation of soft tissues and hemostasis of blood vessels in orthopedic, arthroscopic, and spinal procedures.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K992581: Arthrocare Controller, Arthrocare Cable, Footswitch, Powercord, Spine Wands, Orthowands, Arthrowands.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K992581

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026