510(k) Report

510(k) · Cleared

Cleared

PE 501 PC-Ecg Monitor

K992584510(k) TraditionalCleared Jan 13, 2000164-day reviewClass II21 CFR 870.2800

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Nhe Corp. · MWJ Electrocardiograph, Ambulatory (Without Analysis)

Cleared on Jan 13, 2000 as substantially equivalent to K981394 (Braemar Corp., 1998) and 1 other predicate after a 164-day review. Its family tree reaches back 2 generations to 1992.

Decided
Jan 13, 2000
Review
164 days
Class
Class II
Product code
MWJ
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K923930 (1992). 3 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 1997: 1 other ancestorK923930 · Electrocardiograph Transmitter · Tz Medical, Inc. · 1992K981394 · Braemar ER700 Series Ambulatory Ecg Event Monitor Models ER710,ER720 · Braemar Corp. · 19981990199219941996199820002002
Other ancestors, by generation 1 generation back: 1 other ancestor K981394 · Braemar ER700 Series Ambulatory Ecg Event Monitor Models ER710,ER720 · Braemar Corp. · 1998K923930 · Electrocardiograph Transmitter · Tz Medical, Inc. · 19920
  1. Root · 2 generations backK923930 Electrocardiograph TransmitterTz Medical, Inc. · 1992
  2. 1 generation backK981394 Braemar ER700 Series Ambulatory Ecg Event Monitor Models ER710,ER720Braemar Corp. · 1998
  3. This deviceK992584 PE 501 PC-Ecg MonitorNhe Corp. · 2000
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K923930Electrocardiograph TransmitterTz Medical, Inc.1992—
−1K981394Braemar ER700 Series Ambulatory Ecg Event Monitor Models ER710,ER720Braemar Corp.1998—
0 (this device)K992584PE 501 PC-Ecg MonitorNhe Corp.2000—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199710
FIG. 1 — Lineage of K992584, 1992–2000Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MWJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MWJ device

  1. #1 K254119 Wearable ECG Recorder (YMHeart XY-12)…score 14.1 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K981394Braemar ER700 Series Ambulatory Ecg Event Monitor Models ER710,ER720
Summary page 1
…y disk, direct machine to machine or E-mail. Substantially Equivalent (SE) to: Technological ER 700 Series Ambulatory ECG Event Monitor by Braemar Corp., MN, 510(k)# K981394 PC-ECG, by L.P.I. — International Products Inc., the basic model, PC-ECG, of a PC-ECG series of family with no interpretation fu…
Braemar Corp.1998—
*K963578PC Based Electrocardiograph System (PC-Ecg)
Summary page 1
…., MN, 510(k)# K981394 PC-ECG, by L.P.I. — International Products Inc., the basic model, PC-ECG, of a PC-ECG series of family with no interpretation functions. 510(k)# K963578 characteristics: All three devices compared use similar technologies to acquire patient’s ECG signals, amplify the signals, per…
Intl. Products, Inc.1997—

Also cleared against K981394: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 8 years and passes through 3 companies; a new generation was cleared every 5.9 years on median.
  • None of the 3 ancestors has a recall.
  • 2 other devices also cite its predicate K981394.

How does its category compare?

All MWJ devices

MWJ Electrocardiograph, Ambulatory (Without Analysis): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MWJ

2in 2024

2007: 52008: 12009: 22010: 32011: 32012: 12013: 32014: 22016: 22018: 12021: 12022: 42024: 22026 (partial year): 5
2007high 5 (2007) · low 0 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MWJ

337in 2022

2007: 142 days median2010: 90 days median2011: 206 days median2013: 241 days median2022: 337 days median2026 (partial year): 270 days median
2007high 337 (2022) · low 90 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MWJ

2in 2024

2024: 2
2007high 2 (2024) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MWJ

8in 2025

2009: 52012: 22013: 42014: 12015: 12016: 12017: 22018: 12019: 42020: 122021: 32022: 62023: 52024: 32025: 8
2007high 12 (2020) · low 0 (2007)2025

MAUDE reports naming product code MWJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007514200
20081—00
20092—05
201039000
2011320600
20121—02
2013324104
20142—01
20150—01
20162—01
20170—02
20181—01
20190—04
20200—012
20211—03
2022433706
20230—05
20242—23
20250—08
202652700—

What is it indicated for?

The PE 501 PC-ECG is indicated for acquiring and displaying 2 channel ECG signals through a personal computer and transferring the recorded ECG signals to a remote computer.

It is designed for stationary use and is not for ambulatory use. It is intended for use primarily in out-patient clinics. The PE 501 PC-ECG device should be operated by a licensed healthcare practitioner.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K992584: PE 501 PC-Ecg Monitor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K992584

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026