510(k) Report

510(k) · Cleared

Cleared

Endopath Endoscopic Tissue Fastening System with Coated Vicryl, Models SW210, SW220, SW220,SW230, SW212, SW222 and SW232

K992612510(k) TraditionalCleared Oct 14, 199971-day reviewClass II21 CFR 876.1500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ethicon Endo-Surgery, Inc. · GCJ Laparoscope, General & Plastic Surgery

Cleared on Oct 14, 1999 as substantially equivalent to K980022 (Ethicon Endo-Surgery, Inc., 1998) and 1 other predicate after a 71-day review. Its family tree reaches back 2 generations to 1997.

Decided
Oct 14, 1999
Review
71 days
Class
Class II
Product code
GCJ
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K972679 (1997). No later device cites it as a predicate yet.

  1. Root · 2 generations backK972679 Endopath Endoscopic Tissue Fastening System (Etfs)Ethicon Endo-Surgery, Inc. · 1997
  2. 1 generation backK980022 Endopath Endoscopic Tissue Fastening System (Etfs)Ethicon Endo-Surgery, Inc. · 1998
  3. This deviceK992612 Endopath Endoscopic Tissue Fastening System with Coated Vicryl…Ethicon Endo-Surgery, Inc. · 1999
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K972679Endopath Endoscopic Tissue Fastening System (Etfs)Ethicon Endo-Surgery, Inc.1997—
−1K980022Endopath Endoscopic Tissue Fastening System (Etfs)Ethicon Endo-Surgery, Inc.1998—
0 (this device)K992612Endopath Endoscopic Tissue Fastening System with Coated Vicryl, Models SW210…Ethicon Endo-Surgery, Inc.1999—
FIG. 1 — Lineage of K992612, 1997–1999Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GCJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GCJ device

  1. #1 K214046 780 nm 1688 4K Camera System, 780 nm L11 LED…score 21.4 · 21 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K980022Endopath Endoscopic Tissue Fastening System (Etfs)
Summary page 1
…prietary Name is ENDOPATH® Endoscopic Tissue Fastening System (ETFS) with Coated VICRYL®. Ethicon Endo-Surgery’s ENDOPATH® Endoscopic Tissue Fastening System . (ETFS)-K980022; Ethicon Endo-Surgery’s ENDOPATH® Endoscopic Tissuc Fastening System (ETFS)-K972679. The ENDOPATH® Endoscopic Tissue Fastening…
Ethicon Endo-Surgery, Inc.1998—
*K972679Endopath Endoscopic Tissue Fastening System (Etfs)
Summary page 1
…RYL®. Ethicon Endo-Surgery’s ENDOPATH® Endoscopic Tissue Fastening System . (ETFS)-K980022; Ethicon Endo-Surgery’s ENDOPATH® Endoscopic Tissuc Fastening System (ETFS)-K972679. The ENDOPATH® Endoscopic Tissue Fastening System (ETFS) with Coated VICRYL® is a single patient use reloadable instrument that…
Ethicon Endo-Surgery, Inc.1997—

Also cleared against K980022: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 2 years and passes through 1 company; a new generation was cleared every 1.6 years on median.
  • None of the 2 ancestors has a recall.
  • 1 other device also cites its predicate K980022.

How does its category compare?

All GCJ devices

GCJ Laparoscope, General & Plastic Surgery: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GCJ

21in 2025

2007: 182008: 192009: 212010: 242011: 152012: 172013: 152014: 192015: 262016: 272017: 202018: 212019: 152020: 282021: 182022: 202023: 312024: 292025: 212026 (partial year): 26
2007high 31 (2023) · low 15 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GCJ

108in 2025

2007: 42 days median2008: 73 days median2009: 85 days median2010: 122 days median2011: 113 days median2012: 88 days median2013: 93 days median2014: 90 days median2015: 76 days median2016: 99 days median2017: 77 days median2018: 88 days median2019: 60 days median2020: 61 days median2021: 116 days median2022: 103 days median2023: 109 days median2024: 90 days median2025: 108 days median2026 (partial year): 122 days median
2007high 122 (2010) · low 42 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GCJ

5in 2025

2007: 122008: 162009: 62010: 302011: 92012: 12013: 7, 1 Class I2014: 22016: 52017: 12018: 12022: 12023: 12025: 52026 (partial year): 1
2007high 30 (2010) · low 0 (2015)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · GCJ

5,860in 2025

2007: 1,6392008: 1,3192009: 1,9952010: 2,6572011: 2,1332012: 1,5262013: 1,5652014: 1,7142015: 1,7102016: 2,0802017: 3,4682018: 2,5622019: 2,5782020: 2,6182021: 3,4312022: 3,9452023: 6,0022024: 6,0472025: 5,860
2007high 6,047 (2024) · low 1,319 (2008)2025

MAUDE reports naming product code GCJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071842121,639
20081973161,319
2009218561,995
201024122302,657
20111511392,133
2012178811,526
201315937 (1)1,565
2014199021,714
2015267601,710
2016279952,080
2017207713,468
2018218812,562
2019156002,578
2020286102,618
20211811603,431
20222010313,945
20233110916,002
2024299006,047
20252110855,860
2026261221—

What is it indicated for?

The ENDOPATH® Endoscopic Tissue Fastening System (ETFS) with Coated VICRYL® is intended for use in minimally invasive surgical applications where soft tissue is being approximated with interrupted stitches.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K992612: Endopath Endoscopic Tissue Fastening System with Coated Vicryl, Models SW210, SW220, SW220,SW230, SW212, SW222 and SW232.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K992612

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026