510(k) · Cleared
ClearedSDB Cerclage System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Pioneer Surgical Technology · JDQ Cerclage, Fixation
Cleared on Oct 27, 1999 as substantially equivalent to K844068 (Howmedica Corp., 1985) and 2 other predicates after an 84-day review. Its family tree reaches back 1 generation to 1985. 10 later devices descend from it.
- Decided
- Oct 27, 1999
- Review
- 84 days
- Class
- Class II
- Product code
- JDQ
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 1 generation to K844068 (1985). 3 ancestors in all. 10 later devices descend from it, 6 citing it directly.
- Root · 1 generation backK844068 Trochanter Cable Grip SystemHowmedica Corp. · 1985
- This deviceK992616 SDB Cerclage SystemPioneer Surgical Technology · 1999
- Descendant · cites it directly · 3 of its ownK101126 Pontis Sutures and Suture Anchors with Optional CrimpsCore Essence Orthopaedics, Inc. · 2010
- Descendant · cites it directly · 1 of its ownK151888 Frontier Medical Devices In-line Orthopedic Cable Cerclage SystemFrontier Medical Devices, Inc. · 2015
- Descendant · 2 generations on · 1 of its ownK140127 Ferrofibre Stainless Steel Suture with CrimpPontis Orthopaedics, LLC · 2014
- Descendant · cites it directly · 0 of its ownK231333 STRETTO™ Cable SystemGlobus Medical, Inc. · 2023
- Descendant · cites it directly · 0 of its ownK203408 Summit Patella Plating SystemEndeavor Orthopaedics, LLC · 2021
Showing 5 of 10 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 10 · See all- K101126Pontis Sutures and Suture Anchors with Optional CrimpsCore Essence Orthopaedics, Inc. · 2010 · cites it directly3descendants
- K151888Frontier Medical Devices In-line Orthopedic Cable Cerclage SystemFrontier Medical Devices, Inc. · 2015 · cites it directly1descendant
- K140127Ferrofibre Stainless Steel Suture with CrimpPontis Orthopaedics, LLC · 2014 · 2 generations on1descendant
- K231333STRETTO™ Cable SystemGlobus Medical, Inc. · 2023 · cites it directly0descendants
- K203408Summit Patella Plating SystemEndeavor Orthopaedics, LLC · 2021 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K844068 | Trochanter Cable Grip System | Howmedica Corp. | 1985 | — |
| 0 (this device) | K992616 | SDB Cerclage System | Pioneer Surgical Technology | 1999 | — |
| +1 | K101126 | Pontis Sutures and Suture Anchors with Optional Crimps | Core Essence Orthopaedics, Inc. | 2010 | — |
| +1 | K151888 | Frontier Medical Devices In-line Orthopedic Cable Cerclage System | Frontier Medical Devices, Inc. | 2015 | — |
| +2 | K140127 | Ferrofibre Stainless Steel Suture with Crimp | Pontis Orthopaedics, LLC | 2014 | — |
| +1 | K231333 | STRETTO™ Cable System | Globus Medical, Inc. | 2023 | — |
| +1 | K203408 | Summit Patella Plating System | Endeavor Orthopaedics, LLC | 2021 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1987 | 1 | 0 |
| 1990 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2003 | 1 | 0 |
| 2010 | 1 | 0 |
| 2014 | 2 | 0 |
| 2015 | 2 | 0 |
| 2016 | 1 | 0 |
| 2020 | 1 | 0 |
| 2021 | 1 | 0 |
| 2023 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JDQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JDQ device
- #1 K261271 Cable-Ready® Cable Grip Systemscore 14.7 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (4)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K844068 | Trochanter Cable Grip SystemSummary page 1…Number: CFR 888.3010 Classification Number: 871DQ Device Class: II Devices on Which Substantial Equivalence is Claimed: 1. Dall Miles “Trochanter Cable Grip System” - K844068; 2. Dall Miles “Modified Trochanter Cable Grip System” - K872224; 3. Dall Miles “Trochanter Cable Grip System (Additional Indica… | 1985 |
| * | K872224 | Modified Trochanter Cable Grip SystemSummary page 1…II Devices on Which Substantial Equivalence is Claimed: 1. Dall Miles “Trochanter Cable Grip System” - K844068; 2. Dall Miles “Modified Trochanter Cable Grip System” - K872224; 3. Dall Miles “Trochanter Cable Grip System (Additional Indications)” - K900926; and 4, Stainless Steel cerclage wire, manufac… | 1987 |
| * | K900926 | Trochanter Cable Grip System (Add'l Indications)Summary page 1…r Cable Grip System” - K844068; 2. Dall Miles “Modified Trochanter Cable Grip System” - K872224; 3. Dall Miles “Trochanter Cable Grip System (Additional Indications)” - K900926; and 4, Stainless Steel cerclage wire, manufactured prior ta 1976 12 510(K) SUMMARY (Continued) Device Descrip… | 1990 |
| * | — | Stainless Steel cerclage wire, manufactured prior to 1976 Named without a submission number |
What descends from it? (10)
6 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All JDQ devicesJDQ Cerclage, Fixation: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JDQ
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JDQ
130in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JDQ
5in 2019
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JDQ
84in 2025
MAUDE reports naming product code JDQ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 5 |
| 2008 | 2 | — | 2 | 25 |
| 2009 | 2 | — | 0 | 19 |
| 2010 | 0 | — | 2 | 28 |
| 2011 | 6 | 130 | 0 | 30 |
| 2012 | 3 | 134 | 0 | 130 |
| 2013 | 1 | — | 1 | 321 |
| 2014 | 2 | — | 0 | 223 |
| 2015 | 5 | 92 | 1 | 205 |
| 2016 | 4 | 129 | 0 | 224 |
| 2017 | 1 | — | 0 | 138 |
| 2018 | 6 | 101 | 0 | 182 |
| 2019 | 0 | — | 5 | 158 |
| 2020 | 4 | 93 | 0 | 125 |
| 2021 | 0 | — | 0 | 141 |
| 2022 | 2 | — | 0 | 134 |
| 2023 | 3 | 141 | 0 | 98 |
| 2024 | 3 | 130 | 0 | 115 |
| 2025 | 2 | — | 0 | 84 |
| 2026 | 1 | — | 0 | — |
What is it indicated for?
The SDB Cerclage System devices will be offered in two sizes of cable constructs. The large cable construct shall be indicated for general orthopedic trauma surgery involving the following: olecranon, patella, femur (including periprosthetic fractures), pelvic, acetabular, humeral and ankle fractures; acromioclavicular dislocations; prophylactic banding during total joint procedures; and temporary reduction during ORIF (Open Reduction Internal Fixation) procedures. The small cable size shall be contraindicated for use in the femur ORIF and prophylactic banding during total joint procedures. These devices are intended as single use items.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K992616 · printed Nov 4, 2026
Cite this page
510(k) Report. “K992616: SDB Cerclage System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K992616
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026