Erbe USA, Inc. · GEI Electrosurgical, Cutting & Coagulation & Accessories
Cleared on Oct 14, 1999 as substantially equivalent to K902996 (Beacon Laboratories, Inc., 1990) and 2 other predicates after a 58-day review. Its family tree reaches back 2 generations to 1989.
- Decided
- Oct 14, 1999
- Review
- 58 days
- Class
- Class II
- Product code
- GEI
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 2 generations to K894762 (1989). 5 ancestors in all. No later device cites it as a predicate yet.
- Root · 2 generations backK894762 B100 Disposable HandpieceBeacon Laboratories, Inc. · 1989
- 1 generation backK963189 Erbe Apc 300 Argon Plasma Coagulator and Accessories - Argon Plasma…Erbe USA, Inc. · 1996
- This deviceK992769 Erbe Apc Applicators, Models 20132-106, 20132-107, 20132-109…Erbe USA, Inc. · 1999
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K894762 | B100 Disposable Handpiece | Beacon Laboratories, Inc. | 1989 | — |
| −1 | K963189 | Erbe Apc 300 Argon Plasma Coagulator and Accessories - Argon Plasma Coagulator… | Erbe USA, Inc. | 1996 | — |
| 0 (this device) | K992769 | Erbe Apc Applicators, Models 20132-106, 20132-107, 20132-109, 20132-110… | Erbe USA, Inc. | 1999 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1990 | 2 | 0 |
| 1994 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in GEI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new GEI device
- #1 K231790 The InMode System with the Morpheus8 Applicatorsscore 32.7 · 21 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K902996 | Argon Beam Laparoscopic ElectrodeSummary page 1…antially Equivalent Devices: The ERBE APC Applicators are substantially equivalent to the following legally marketed devices: Beacon’s Argon Beam Laparoscopic Electrode (K902996), Everest Medical’s Bipolar Laparoscopic Cutting Electrosurgical Needle (K945975), and ERBE USA’s APC Probes (K963189). Device… | 1990 |
| * | K945975 | Evershears (R) Scissors, Bilap (R) Probes, Bicoag (R) ForcepsSummary page 1…to the following legally marketed devices: Beacon’s Argon Beam Laparoscopic Electrode (K902996), Everest Medical’s Bipolar Laparoscopic Cutting Electrosurgical Needle (K945975), and ERBE USA’s APC Probes (K963189). Device Description: The APC Applicators are provided in various shaft lengths, shaft di… | 1994 |
| * | K963189 | Erbe Apc 300 Argon Plasma Coagulator and Accessories - Argon Plasma Coagulator and…Summary page 1…ices: Beacon’s Argon Beam Laparoscopic Electrode (K902996), Everest Medical’s Bipolar Laparoscopic Cutting Electrosurgical Needle (K945975), and ERBE USA’s APC Probes (K963189). Device Description: The APC Applicators are provided in various shaft lengths, shaft diameters, and bend angles to accommodat… | 1996 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 10 years and passes through 2 companies; a new generation was cleared every 7.2 years on median.
- None of the 5 ancestors has a recall.
- 1 other device also cites its predicate K902996.
How does its category compare?
All GEI devicesGEI Electrosurgical, Cutting & Coagulation & Accessories: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · GEI
52in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · GEI
113in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · GEI
4in 2025
Class I (14 since 2007) Class II/III not classified
Adverse event reports per year · GEI
7,592in 2025
MAUDE reports naming product code GEI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 50 | 51 | 21 | 2,795 |
| 2008 | 61 | 71 | 19 | 2,556 |
| 2009 | 42 | 130 | 27 | 3,591 |
| 2010 | 46 | 109 | 51 | 3,377 |
| 2011 | 35 | 135 | 32 | 4,463 |
| 2012 | 39 | 133 | 30 | 5,216 |
| 2013 | 48 | 136 | 13 | 4,897 |
| 2014 | 49 | 103 | 3 | 4,908 |
| 2015 | 47 | 123 | 4 | 4,936 |
| 2016 | 64 | 108 | 3 | 5,616 |
| 2017 | 52 | 72 | 2 | 6,073 |
| 2018 | 47 | 93 | 6 | 6,545 |
| 2019 | 48 | 93 | 5 | 7,067 |
| 2020 | 59 | 105 | 1 | 6,490 |
| 2021 | 46 | 146 | 6 | 6,354 |
| 2022 | 55 | 150 | 49 | 6,103 |
| 2023 | 65 | 104 | 27 (4) | 7,176 |
| 2024 | 59 | 125 | 22 (10) | 7,897 |
| 2025 | 52 | 113 | 4 | 7,592 |
| 2026 | 43 | 183 | 8 | — |
What is it indicated for?
The ERBE APC Applicators’ intended use is for the delivery of argon gas plasma energy for coagulation of tissue.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K992769 · printed Nov 5, 2026
Cite this page
510(k) Report. “K992769: Erbe Apc Applicators, Models 20132-106, 20132-107, 20132-109, 20132-110, 20132-11, 20132-112,20132-113, 20132-114, 2013-.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K992769
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026