510(k) · Cleared
ClearedCascade Liquid Coagulation Control Levels 1, 2, and 3
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Medical Analysis Systems, Inc. · GGN Plasma, Coagulation Control
Cleared on Nov 22, 1999 after a 91-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Nov 22, 1999
- Review
- 91 days
- Class
- Class II
- Product code
- GGN
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in GGN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All GGN devicesGGN Plasma, Coagulation Control: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · GGN
4in 2017
2026 to Oct 25, outlined.
Median 510(k) review, days · GGN
96in 2017
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · GGN
1in 2019
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · GGN
4in 2018
MAUDE reports naming product code GGN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 47 | 0 | 0 |
| 2008 | 1 | — | 0 | 0 |
| 2009 | 2 | — | 0 | 37 |
| 2010 | 3 | 23 | 4 | 17 |
| 2011 | 2 | — | 1 | 30 |
| 2012 | 1 | — | 0 | 10 |
| 2013 | 3 | 441 | 3 | 9 |
| 2014 | 2 | — | 0 | 5 |
| 2015 | 0 | — | 0 | 10 |
| 2016 | 2 | — | 0 | 9 |
| 2017 | 4 | 96 | 0 | 11 |
| 2018 | 0 | — | 0 | 4 |
| 2019 | 0 | — | 1 | 0 |
| 2020 | 0 | — | 0 | 0 |
| 2021 | 0 | — | 0 | 0 |
| 2022 | 0 | — | 0 | 0 |
| 2023 | 0 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 0 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 0 | — | 2 | — |
What is it indicated for?
CASCADE™ Liquid Coagulation Control, Levels 1, 2, and 3 is a human plasma based quality control material intended for use in the clinical laboratory as a consistent test sample of known concentration for monitoring the performance of routine coagulation assays (prothrombin time, activated partial thromboplastin time, and fibrinogen assays). The user can compare recovered values with expected ranges as a means of assuring consistent performance of reagent and instrument. This product is for use on the MLA 1600 analyzer.
Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K992829 · printed Nov 6, 2026
Cite this page
510(k) Report. “K992829: Cascade Liquid Coagulation Control Levels 1, 2, and 3.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K992829
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026