510(k) Report

510(k) · Cleared

Cleared

Lucitone FRS Flexibel Dental Resin

K992956510(k) TraditionalCleared Oct 6, 199934-day reviewClass II21 CFR 872.3760

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Dentsply Intl. · EBI Resin, Denture, Relining, Repairing, Rebasing

Cleared on Oct 6, 1999 after a 34-day review. The FDA summary names its predicate without a number. 12 later devices descend from it.

Decided
Oct 6, 1999
Review
34 days
Class
Class II
Product code
EBI
Recalls
None
Predicates
0

12 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2006: 1 descendant cleared2013: 1 descendant cleared2014: 1 descendant cleared2015: 1 descendant cleared2016: 1 descendant cleared2017: 3 descendants cleared2018: 1 descendant cleared2022: 1 descendant cleared2023: 1 descendant cleared2025: 1 descendant cleared1995200020052010201520202025
  1. This deviceK992956 Lucitone FRS Flexibel Dental ResinDentsply Intl. · 1999
  2. Descendant · cites it directly · 10 of its ownK123220 Vertex Thermosens RigidVertex-Dental B.V. · 2013
  3. Descendant · 2 generations on · 8 of its ownK132725 Juvora Dentqal DiscJuvora · 2014
  4. Descendant · 3 generations on · 3 of its ownK160918 JUVORA Dental Disc, Ceramill PEEK by JUVORAJuvora · 2017
  5. Descendant · 3 generations on · 3 of its ownK152113 BioHPP - breCAM.BioHPPBredent GmbH & Co. KG · 2016
  6. Descendant · 4 generations on · 1 of its ownK220329 G-CAMGraphenano Dental S.L. · 2022 · Recalled

Showing 5 of 12 descendants. See all descendants

Descendants cleared per year

2006: 12013: 12014: 12015: 12016: 12017: 32018: 12022: 12023: 12025: 1
2006high 3 (2017) · low 0 (2007)2026

Most influential descendants

Showing 5 of 12 · See all
  • K123220Vertex Thermosens RigidVertex-Dental B.V. · 2013 · cites it directly10descendants
  • K132725Juvora Dentqal DiscJuvora · 2014 · 2 generations on8descendants
  • K160918JUVORA Dental Disc, Ceramill PEEK by JUVORAJuvora · 2017 · 3 generations on3descendants
  • K152113BioHPP - breCAM.BioHPPBredent GmbH & Co. KG · 2016 · 3 generations on3descendants
  • K220329G-CAMGraphenano Dental S.L. · 2022 · 4 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K992956Lucitone FRS Flexibel Dental ResinDentsply Intl.1999—
+1K123220Vertex Thermosens RigidVertex-Dental B.V.2013—
+2K132725Juvora Dentqal DiscJuvora2014—
+3K160918JUVORA Dental Disc, Ceramill PEEK by JUVORAJuvora2017—
+3K152113BioHPP - breCAM.BioHPPBredent GmbH & Co. KG2016—
+4K220329G-CAMGraphenano Dental S.L.20221

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200610
201310
201410
201510
201610
201730
201810
202210
202310
202510
FIG. 1 — Lineage of K992956, 1999–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in EBI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new EBI device

  1. #1 K250617 Apex Flexscore 18.3 · 1 generation · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Valplast® Resin Material
Named without a submission number
—

What descends from it? (12)

See all 12

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K123220Vertex Thermosens RigidVertex-Dental B.V.201310
K061501Flexo Dental Resin MaterialAci, Inc.20060

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K123220 (Vertex-Dental B.V., 2013) has gone furthest, with 10 descendants of its own.

How does its category compare?

All EBI devices

EBI Resin, Denture, Relining, Repairing, Rebasing: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · EBI

11in 2025

2007: 102008: 62009: 32010: 42011: 112012: 32013: 52014: 52015: 92016: 72017: 82018: 52019: 42020: 62021: 42022: 112023: 112024: 92025: 112026 (partial year): 7
2007high 11 (2011) · low 3 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · EBI

79in 2025

2007: 53 days median2008: 124 days median2009: 234 days median2010: 95 days median2011: 113 days median2012: 85 days median2013: 135 days median2014: 102 days median2015: 106 days median2016: 147 days median2017: 196 days median2018: 158 days median2019: 127 days median2020: 283 days median2021: 99 days median2022: 154 days median2023: 96 days median2024: 90 days median2025: 79 days median2026 (partial year): 87 days median
2007high 283 (2020) · low 53 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · EBI

2in 2022

2018: 22022: 2
2007high 2 (2018) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · EBI

34in 2025

2007: 72008: 22009: 52010: 42011: 62012: 92013: 52014: 92015: 82016: 92017: 22018: 22019: 102020: 82021: 252022: 22023: 132024: 12025: 34
2007high 34 (2025) · low 1 (2024)2025

MAUDE reports naming product code EBI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007105307
2008612402
2009323405
201049504
20111111306
201238509
2013513505
2014510209
2015910608
2016714709
2017819602
2018515822
20194127010
2020628308
2021499025
20221115422
20231196013
202499001
20251179034
20267870—

What is it indicated for?

Used for fabrication of partial or full removable dentures, as well as occlusal splints and night guards.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K992956: Lucitone FRS Flexibel Dental Resin.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K992956

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026