510(k) Report

510(k) · Cleared

Cleared

Hewlett Packard Multifunction Pediatric Defib Function, Model M3503A & M3504A

K992977510(k) TraditionalCleared Dec 1, 199989-day reviewClass III21 CFR 870.5310

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Hewlett-Packard Co. · MKJ Automated External Defibrillators (Non-Wearable)

Cleared on Dec 1, 1999 after an 89-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 1 of the 2 devices in its family, counting itself, has a Class I recall. 1 later device descends from it.

Decided
Dec 1, 1999
Review
89 days
Class
Class III
Product code
MKJ
Recalls
None
Predicates
0

1 later device descends from it, 1 citing it directly. 1 of the 2 devices in this family, counting this one, has a Class I recall.

Descendants, by year cleared 2008: 1 descendant cleared, 1 with a Class I recall11995200020052010201520202025
  1. This deviceK992977 Hewlett Packard Multifunction Pediatric Defib Function, Model M3503A…Hewlett-Packard Co. · 1999
  2. Descendant · cites it directly · 0 of its ownK081371 Skintact Pediatric Multifunction Electrodes with DH03 GelLeonhard Lang GmbH · 2008 · Recalled (Class I)

Class I recalls in this family

Most influential descendants

Showing 1 of 1 · See all
  • K081371Skintact Pediatric Multifunction Electrodes with DH03 GelLeonhard Lang GmbH · 2008 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K992977Hewlett Packard Multifunction Pediatric Defib Function, Model M3503A & M3504AHewlett-Packard Co.1999—
+1K081371Skintact Pediatric Multifunction Electrodes with DH03 GelLeonhard Lang GmbH2008Class I

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200811
FIG. 1 — Lineage of K992977, 1999–2008Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K081371Skintact Pediatric Multifunction Electrodes with DH03 Gel Class ILeonhard Lang GmbH20080

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K081371Skintact Pediatric Multifunction Electrodes with DH03 GelLeonhard Lang GmbH · 2008 · Cites it directly · ◆ in the 2008 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • Of its descendants, K081371 (Leonhard Lang GmbH, 2008) has gone furthest, with 0 descendants of its own.

How does its category compare?

All MKJ devices

MKJ Automated External Defibrillators (Non-Wearable): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MKJ

48in 2025

2007: 72008: 132009: 82010: 42011: 112012: 102013: 72014: 112015: 62017: 42018: 202019: 252020: 522021: 412022: 192023: 242024: 272025: 482026 (partial year): 31
2007high 52 (2020) · low 0 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MKJ

156in 2015

2007: 69 days median2008: 141 days median2009: 165 days median2010: 250 days median2011: 36 days median2012: 197 days median2013: 191 days median2014: 196 days median2015: 156 days median
2007high 250 (2010) · low 36 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MKJ

1in 2025

2007: 122008: 242009: 372010: 352011: 72012: 5, 1 Class I2013: 42014: 24, 15 Class I2015: 12016: 2, 1 Class I2017: 6, 4 Class I2018: 32019: 6, 2 Class I2020: 22021: 42022: 32023: 112024: 52025: 12026 (partial year): 3
2007high 37 (2009) · low 1 (2015)2026

Class I (23 since 2007) Class II/III not classified

Adverse event reports per year · MKJ

13,315in 2025

2007: 3,9582008: 4,7522009: 6,7822010: 7,3992011: 8,1702012: 9,7322013: 14,9552014: 15,3992015: 16,1292016: 17,0622017: 16,6842018: 16,5912019: 16,8612020: 16,1972021: 16,3002022: 14,8672023: 13,7662024: 15,1092025: 13,315
2007high 17,062 (2016) · low 3,958 (2007)2025

MAUDE reports naming product code MKJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007769123,958
200813141244,752
20098165376,782
20104250357,399
2011113678,170
2012101975 (1)9,732
20137191414,955
20141119624 (15)15,399
20156156116,129
20160—2 (1)17,062
20174—6 (4)16,684
201820—316,591
201925—6 (2)16,861
202052—216,197
202141—416,300
202219—314,867
202324—1113,766
202427—515,109
202548—113,315
202631—3—

What is it indicated for?

The Hewlett Packard External Pediatric electrodes are indicated for use in external Pacing, Defibrillation and Monitoring applications as a non-sterile, disposable device for single pediatric patient use, only. The M3503A & M3504A electrodes provide the conductive interface between the defibrillator and/or the external transcutaneous (noninvasive) cardiac pacemaker and the pediatric patients skin. The electrode is intended for use on pediatric patients.…

Read the full statement (122 words)

The Hewlett Packard External Pediatric electrodes are indicated for use in external Pacing, Defibrillation and Monitoring applications as a non-sterile, disposable device for single pediatric patient use, only. The M3503A & M3504A electrodes provide the conductive interface between the defibrillator and/or the external transcutaneous (noninvasive) cardiac pacemaker and the pediatric patients skin. The electrode is intended for use on pediatric patients.

When a patient requires defibrillation, cardioversion or extemal pacing, these electrodes will be applied to the pediatric paticnt and connected to the instrument. This device is intended for use on defibrillators whose output is classified as low power (360 Joule maximum.)

The M3503A & M3504A Pediatric electrodes are designed for, and to be used, with the

<+he Hewlett Packard Codemaster Defibrillator.

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K992977: Hewlett Packard Multifunction Pediatric Defib Function, Model M3503A & M3504A.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K992977

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026