Baho Autoclavable Cystoscope

K992983510(k) TraditionalCleared Oct 7, 199934-day reviewClass II21 CFR 876.1500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Innovative Endoscopy Components, LLC · FAJ Cystoscope And Accessories, Flexible/Rigid

Cleared on Oct 7, 1999 after a 34-day review. The FDA summary names its predicate without a number. 22 later devices descend from it.

Decided
Oct 7, 1999
Review
34 days
Class
Class II
Product code
FAJ
Recalls
None
Predicates
0

22 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2003: 1 descendant cleared2007: 1 descendant cleared2010: 1 descendant cleared2015: 1 descendant cleared2017: 2 descendants cleared2016: 1 descendant cleared2025: 5 descendants cleared2020: 5 descendants cleared2026: 3 descendants cleared2019: 2 descendants clearedReference device: K982276 · Baho Autoclavable Laparoscope · Microptix Int'L, LLC · 1999 · recalled1995200020052010201520202025
  1. This deviceK992983 Baho Autoclavable CystoscopeInnovative Endoscopy Components, LLC · 1999
  2. Descendant · cites it directly · 21 of its ownK031141 Asap Cystoscope; Asap Laparoscope; Asap Larygoscope; Asap…Asap Endoscopic Products GmbH · 2003
  3. Descendant · 2 generations on · 19 of its ownK060899 Flexilux II Cystoscope and HysteroscopeSchoelly Imaging, Inc. · 2007
  4. Descendant · 3 generations on · 18 of its ownK150158 Schoelly Cystoscopes/Hysteroscopes and AccessoriesSchoelly Fiberoptic GmbH · 2015 · Recalled
  5. Descendant · 4 generations on · 7 of its ownK161110 ClearPetra Suction-Evacuation SheathWell Lead Medical Co., Ltd. · 2016
  6. Descendant · 4 generations on · 5 of its ownK170660 Endosee Hysteroscope with Disposable Diagnostic (Dx) CannulaCooperSurgical, Inc. · 2017

Showing 5 of 22 descendants. See all descendants

Descendants cleared per year

2003: 12007: 12010: 12015: 12016: 12017: 22019: 22020: 52025: 52026: 3
2003high 5 (2020) · low 0 (2004)2026

Most influential descendants

Showing 5 of 22 · See all
  • K031141Asap Cystoscope; Asap Laparoscope; Asap Larygoscope; Asap OesophagoscopeAsap Endoscopic Products GmbH · 2003 · cites it directly21descendants
  • K060899Flexilux II Cystoscope and HysteroscopeSchoelly Imaging, Inc. · 2007 · 2 generations on19descendants
  • K150158Schoelly Cystoscopes/Hysteroscopes and AccessoriesSchoelly Fiberoptic GmbH · 2015 · 3 generations on18descendants
  • K161110ClearPetra Suction-Evacuation SheathWell Lead Medical Co., Ltd. · 2016 · 4 generations on7descendants
  • K170660Endosee Hysteroscope with Disposable Diagnostic (Dx) CannulaCooperSurgical, Inc. · 2017 · 4 generations on5descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K992983Baho Autoclavable CystoscopeInnovative Endoscopy Components, LLC1999—
+1K031141Asap Cystoscope; Asap Laparoscope; Asap Larygoscope; Asap OesophagoscopeAsap Endoscopic Products GmbH2003—
+2K060899Flexilux II Cystoscope and HysteroscopeSchoelly Imaging, Inc.2007—
+3K150158Schoelly Cystoscopes/Hysteroscopes and AccessoriesSchoelly Fiberoptic GmbH20151
+4K161110ClearPetra Suction-Evacuation SheathWell Lead Medical Co., Ltd.2016—
+4K170660Endosee Hysteroscope with Disposable Diagnostic (Dx) CannulaCooperSurgical, Inc.2017—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200310
200710
201010
201510
201610
201720
201920
202050
202550
202630
FIG. 1 — Lineage of K992983, 1999–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FAJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FAJ device

  1. #1 K193095 Ambu aScope 4 Cystoscore 31.5 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Storz Model # 27005
Named without a submission number
—
*—Wolf Model # 8650.../8660...
Named without a submission number
—
†K982276Baho Autoclavable LaparoscopeMicroptix Int'L, LLC19991

What descends from it? (22)

See all 22

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K031141Asap Cystoscope; Asap Laparoscope; Asap Larygoscope; Asap OesophagoscopeAsap Endoscopic Products GmbH200321

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K031141 (Asap Endoscopic Products GmbH, 2003) has gone furthest, with 21 descendants of its own.

How does its category compare?

All FAJ devices

FAJ Cystoscope And Accessories, Flexible/Rigid: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FAJ

8in 2025

2007: 22009: 22010: 12012: 12014: 12016: 12017: 22018: 22019: 32020: 22021: 32022: 52023: 52024: 92025: 82026 (partial year): 5
2007high 9 (2024) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FAJ

98in 2025

2019: 207 days median2021: 127 days median2022: 170 days median2023: 207 days median2024: 130 days median2025: 98 days median2026 (partial year): 123 days median
2007high 207 (2019) · low 98 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FAJ

7in 2023

2017: 12022: 12023: 7
2007high 7 (2023) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FAJ

2,690in 2025

2007: 92008: 102009: 102010: 92011: 132012: 82013: 122014: 62015: 282016: 752017: 792018: 792019: 1022020: 3392021: 4942022: 7442023: 9202024: 8922025: 2,690
2007high 2,690 (2025) · low 6 (2014)2025

MAUDE reports naming product code FAJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—09
20080—010
20092—010
20101—09
20110—013
20121—08
20130—012
20141—06
20150—028
20161—075
20172—179
20182—079
201932070102
20202—0339
202131270494
202251701744
202352077920
202491300892
202589802,690
202651230—

What is it indicated for?

Like the predicate devices, the BAHO autoclavable Cystoscope is indicated for use in the visual examination of body cavities, hollow organs and canals and using additional accessories, to perform various diagnostic and therapeutic procedures.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K992983: Baho Autoclavable Cystoscope.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K992983

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026