ClearedMedica Indirect Immunofluorescence (Iif) Anti- Endomysial Antibody (Aema) Test Kit, Model 6001-Esd
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Medica, Inc. · MVM Autoantibodies, Endomysial (Tissue Transglutaminase)
Cleared on Nov 1, 1999 after a 53-day review. The FDA summary names its predicate without a number.
- Decided
- Nov 1, 1999
- Review
- 53 days
- Class
- Class II
- Product code
- MVM
- Recalls
- None
- Predicates
- 0
The FDA summary names its predicate without a number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MVM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MVM device
- #1 K200230 Aptiva Celiac Disease IgG Reagentscore 2.2 · 2 generations · no Class I recall
- #2 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | Scimedx Anti-Endomysial IgA (EMA) Test System Named without a submission number |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All MVM devicesMVM Autoantibodies, Endomysial (Tissue Transglutaminase): FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · MVM
2in 2021
2026 to Oct 25, outlined.
Median 510(k) review, days · MVM
275in 2011
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MVM
No recall names MVM since 2007.
Adverse event reports per year · MVM
1in 2024
MAUDE reports naming product code MVM, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 0 |
| 2008 | 3 | 98 | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 2 | — | 0 | 0 |
| 2011 | 3 | 275 | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 2 | — | 0 | 0 |
| 2014 | 1 | — | 0 | 0 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 0 | — | 0 | 1 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 2 | — | 0 | 0 |
| 2020 | 0 | — | 0 | 0 |
| 2021 | 2 | — | 0 | 0 |
| 2022 | 0 | — | 0 | 0 |
| 2023 | 0 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 1 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
MeDiCa Indirect Immunofluorescence (IIF) Anti-Endomysial Antibody Test Kit is used for the qualitative and semi-quantitative detection of IgA class endomysial autoantibodies (AEmA) in human serum as an aid in the diagnosis of Celiac Disease and other related disorders such as Dermatitis Herpetiformis.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K993034 · printed Nov 6, 2026
Cite this page
510(k) Report. “K993034: Medica Indirect Immunofluorescence (Iif) Anti- Endomysial Antibody (Aema) Test Kit, Model 6001-Esd.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K993034
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026