# K993289: Smith & Nephew Compression Hip Screw System, Intramedullary Hip Screw System

- Pathway: 510(k) (Abbreviated)
- Applicant: Smith & Nephew, Inc.
- Decided: Dec 20, 1999 after 80 days
- Product code: KTT (Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component)
- Device class: 2
- Regulation: 21 CFR 888.3030
- Recalls of this device: none
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
No predicates in its family tree.
182 later devices descend from it; 13 cite it directly.
0 of 183 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- None. The FDA summary names its predicate without a number.
- (no number) IMHS Hip Screw Systems: named in the summary without a submission number
- (no number) Titanium Classic Compression Hip Screw System: named in the summary without a submission number
- (no number) Osteotomy/Blade Plates: named in the summary without a submission number
- (no number) Medoff Sliding Plate: named in the summary without a submission number
- (no number) Biomet Compression Hip Screw System: named in the summary without a submission number
- (no number) Vari-Angle Hip System: named in the summary without a submission number
- (no number) ACE Cannulated Hip Screw System: named in the summary without a submission number
- (no number) Alta Modular Trauma System: named in the summary without a submission number
- (no number) NoLok/Keyed Compression Hip Screw System: named in the summary without a submission number
- (no number) Free-Lock Femoral Fixation System: named in the summary without a submission number
- (no number) Dynamic Hip/Condylar Screw System: named in the summary without a submission number
- (no number) Synthes Femoral Nail System: named in the summary without a submission number
- (no number) Howmedica Gamma Locking Nail System: named in the summary without a submission number
- (no number) Angled/Condylar/Osteotomy Blade Plates: named in the summary without a submission number

## Most influential descendants
- K040212: Trigen Intertan (2004), 121 descendants of its own
- K072818: Peri-Loc Periartricular LCK Pit Sys-Prox Fem Plates/Screws.Calbe Access (2007), 93 descendants of its own
- K083032: Peri-Loc Bone Plating and Screw System (2009), 77 descendants of its own
- K051557: Trigen Retrograde Femoral, Supracondylar and Tibial Nails (2005), 69 descendants of its own
- K061019: Trigen Meta-Nail Retrograde Femoral and Tibial Nails (2006), 60 descendants of its own

## Indications for use
The Trauma Internal Fixation System is used for fracture fixation in the proximal and distal regions of the femur. In particular, indications for use in adult and pediatric patients are as follows: Adult indications: 1. Intracapsular fractures of the femoral neck. (For high subcapsular fractures it may be more prudent to select a prosthesis in lieu of internal fixation to reduce the risk of a nonunion or avascular necrosis of the femoral head). 2. Trochanteric or subtrochanteric fractures with appropriate additional postoperative precautions about weight bearing and more than sedentary activity. 3. Osteotomies for patients with diseases or deformities of the hip. 4. Hip arthrodesis. 5. Supracondylar fractures and distal femoral fractures using a supracondylar plate. 6. Ipsilateral femoral shaft/neck fractures (IMHS only). Pediatric indications: 1. Congenital coxa vara. 2. Congenital dislocation of the hip. 3. Subluxation or dislocation secondary to neurologic disorders such as cerebral palsy, myelomeningocele, poliomyelitis, etc. Usually valgus-anteversion deformities. 4. Coxa plana (Legg-Calve-Perthes disease) for containment of the head completely within the acetabulum.

Source page: https://510kreport.com/device/K993289
Methodology: https://510kreport.com/methodology
