510(k) Report

510(k) · Cleared

Cleared

Transluminal Balloon Dilatation Catheter

K993305510(k) TraditionalCleared Apr 10, 2000189-day reviewClass II21 CFR 870.1250

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Boston Scientific Corp · LIT Catheter, Angioplasty, Peripheral, Transluminal

Cleared on Apr 10, 2000 after a 189-day review. The FDA summary names its predicate without a number. 16 later devices descend from it.

Decided
Apr 10, 2000
Review
189 days
Class
Class II
Product code
LIT
Recalls
None
Predicates
0

16 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2011: 2 descendants cleared2014: 3 descendants cleared2022: 2 descendants cleared2020: 1 descendant cleared2016: 2 descendants cleared2017: 1 descendant cleared2023: 2 descendants cleared2012: 1 descendant cleared2025: 1 descendant cleared2026: 1 descendant cleared200020052010201520202025
  1. This deviceK993305 Transluminal Balloon Dilatation CatheterBoston Scientific Corp · 2000
  2. Descendant · cites it directly · 15 of its ownK103751 Mustang Balloon Dilatation CathetersBoston Scientific · 2011
  3. Descendant · 2 generations on · 2 of its ownK113681 Gladiator Pta Balloon Dilation CatheterBoston Scientific · 2012
  4. Descendant · 2 generations on · 1 of its ownK201170 Athletis PTA Balloon Dilatation CatheterBoston Scientific Corporation · 2020
  5. Descendant · 2 generations on · 1 of its ownK160256 Polux , Minerva and Atropos PTA Balloon Dilatation CatheterBrosmed Medical Co., Ltd. · 2016
  6. Descendant · 3 generations on · 1 of its ownK132810 Gladiator Elite Pta Balloon Dilatation CatheterBoston Scientific Corp · 2014

Showing 5 of 16 descendants. See all descendants

Descendants cleared per year

2011: 22012: 12014: 32016: 22017: 12020: 12022: 22023: 22025: 12026: 1
2011high 3 (2014) · low 0 (2013)2026

Most influential descendants

Showing 5 of 16 · See all
  • K103751Mustang Balloon Dilatation CathetersBoston Scientific · 2011 · cites it directly15descendants
  • K113681Gladiator Pta Balloon Dilation CatheterBoston Scientific · 2012 · 2 generations on2descendants
  • K201170Athletis PTA Balloon Dilatation CatheterBoston Scientific Corporation · 2020 · 2 generations on1descendant
  • K160256Polux , Minerva and Atropos PTA Balloon Dilatation CatheterBrosmed Medical Co., Ltd. · 2016 · 2 generations on1descendant
  • K132810Gladiator Elite Pta Balloon Dilatation CatheterBoston Scientific Corp · 2014 · 3 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K993305Transluminal Balloon Dilatation CatheterBoston Scientific Corp2000—
+1K103751Mustang Balloon Dilatation CathetersBoston Scientific2011—
+2K113681Gladiator Pta Balloon Dilation CatheterBoston Scientific2012—
+2K201170Athletis PTA Balloon Dilatation CatheterBoston Scientific Corporation2020—
+2K160256Polux , Minerva and Atropos PTA Balloon Dilatation CatheterBrosmed Medical Co., Ltd.2016—
+3K132810Gladiator Elite Pta Balloon Dilatation CatheterBoston Scientific Corp2014—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201120
201210
201430
201620
201710
202010
202220
202320
202510
202610
FIG. 1 — Lineage of K993305, 2000–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LIT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LIT device

  1. #1 K241040 Amethyst HP PTA OTW 0.035 Catheterscore 13.9 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Ultra-thin Diamond™ Balloon Dilatation Catheter
Named without a submission number
—
*—Courier ST™ Balloon Dilatation Catheter
Named without a submission number
—

What descends from it? (16)

See all 16

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K103751Mustang Balloon Dilatation CathetersBoston Scientific201115

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K103751 (Boston Scientific, 2011) has gone furthest, with 15 descendants of its own.

How does its category compare?

All LIT devices

LIT Catheter, Angioplasty, Peripheral, Transluminal: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LIT

3in 2025

2007: 62008: 82009: 72010: 132011: 102012: 192013: 142014: 122015: 192016: 112017: 92018: 62019: 42020: 92021: 42022: 82023: 62024: 62025: 32026 (partial year): 4
2007high 19 (2012) · low 3 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LIT

90in 2025

2007: 64 days median2008: 53 days median2009: 29 days median2010: 78 days median2011: 82 days median2012: 29 days median2013: 79 days median2014: 90 days median2015: 112 days median2016: 116 days median2017: 57 days median2018: 118 days median2019: 40 days median2020: 125 days median2021: 61 days median2022: 122 days median2023: 167 days median2024: 43 days median2025: 90 days median2026 (partial year): 205 days median
2007high 205 (2026) · low 29 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LIT

1in 2025

2009: 22010: 12013: 2, 2 Class I2014: 32016: 12018: 22019: 32021: 12024: 22025: 1
2007high 3 (2014) · low 0 (2007)2026

Class I (2 since 2007) Class II/III not classified

Adverse event reports per year · LIT

2,073in 2025

2007: 5772008: 5132009: 6232010: 8092011: 8572012: 1,2772013: 1,2422014: 1,1782015: 1,2792016: 1,5292017: 2,0812018: 2,1882019: 2,4052020: 2,4432021: 2,4922022: 2,1552023: 1,8072024: 1,9132025: 2,073
2007high 2,492 (2021) · low 513 (2008)2025

MAUDE reports naming product code LIT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20076640577
20088530513
20097292623
201013781809
201110820857
2012192901,277
201314792 (2)1,242
2014129031,178
20151911201,279
20161111611,529
201795702,081
2018611822,188
201944032,405
2020912502,443
202146112,492
2022812202,155
2023616701,807
202464321,913
202539012,073
202642050—

What is it indicated for?

The Semi-Compliant 35 Balloon Dilitation Catheter is indicated for percutaneous transluminal angioplasty of the iliac, femoral, ilio-femoral, popliteal, and renal arteries and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K993305: Transluminal Balloon Dilatation Catheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K993305

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026