510(k) · Cleared
ClearedAcumed Suture Anchor
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Acu Med, Inc. · MBI Fastener, Fixation, Nondegradable, Soft Tissue
Cleared on Jan 13, 2000 after a 77-day review. The FDA summary names its predicate without a number.
- Decided
- Jan 13, 2000
- Review
- 77 days
- Class
- Class II
- Product code
- MBI
- Recalls
- None
- Predicates
- 0
The FDA summary names its predicate without a number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MBI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MBI device
- #1 K203268 Arthrex FiberTak Suture Anchorscore 21.4 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (4)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | Mitek GII Anchor Named without a submission number | |
| * | — | Mitek SuperAnchor Named without a submission number | |
| * | — | Linvatec Revo Named without a submission number | |
| * | — | Zimmer Statak Named without a submission number |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All MBI devicesMBI Fastener, Fixation, Nondegradable, Soft Tissue: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · MBI
27in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MBI
58in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MBI
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MBI
3,826in 2025
MAUDE reports naming product code MBI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 16 | 80 | 24 | 240 |
| 2008 | 10 | 69 | 6 | 338 |
| 2009 | 19 | 82 | 2 | 355 |
| 2010 | 17 | 76 | 3 | 291 |
| 2011 | 30 | 75 | 23 | 328 |
| 2012 | 24 | 94 | 6 | 371 |
| 2013 | 31 | 100 | 2 | 442 |
| 2014 | 23 | 101 | 0 | 504 |
| 2015 | 23 | 85 | 0 | 507 |
| 2016 | 17 | 94 | 0 | 795 |
| 2017 | 17 | 70 | 4 | 675 |
| 2018 | 16 | 91 | 2 | 1,072 |
| 2019 | 31 | 90 | 0 | 1,303 |
| 2020 | 35 | 83 | 1 | 1,454 |
| 2021 | 18 | 107 | 0 | 1,890 |
| 2022 | 19 | 64 | 0 | 1,591 |
| 2023 | 52 | 57 | 1 | 2,503 |
| 2024 | 22 | 30 | 1 | 3,779 |
| 2025 | 27 | 58 | 1 | 3,826 |
| 2026 | 30 | 63 | 0 | — |
What is it indicated for?
This deviece is intended for anchoring soft tissue to bose in soft tissue repair of the foot and ankle and rotator cuff repair.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K993657 · printed Nov 4, 2026
Cite this page
510(k) Report. “K993657: Acumed Suture Anchor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K993657
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)