510(k) Report

510(k) · Cleared

Cleared

Disposable and Reusable Ball and Loop Electrodes

K993777510(k) TraditionalCleared May 25, 2000199-day reviewClass II21 CFR 884.4120

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

R-Group Intl. · HGI Electrocautery, Gynecologic (And Accessories)

Cleared on May 25, 2000 after a 199-day review. FDA’s file for it is a 510(k) statement, which names no predicate.

Decided
May 25, 2000
Review
199 days
Class
Class II
Product code
HGI
Recalls
None
Predicates
0

FDA’s file for it is a 510(k) statement, which names no predicate.

FIG. 1 — Lineage of K993777Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HGI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HGI device

  1. #1 K202915 IRIS Thermocoagulator and Digital Colposcopescore 2.1 · 4 generations · no Class I recall
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All HGI devices

HGI Electrocautery, Gynecologic (And Accessories): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · HGI

1in 2021

2007: 12012: 12014: 12016: 12021: 1
2007high 1 (2007) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HGI

Too few HGI 510(k)s in any year since 2007 to give a median.

Recalls per year · HGI

7in 2021

2012: 12014: 12019: 32021: 7
2007high 7 (2021) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HGI

41in 2025

2008: 12009: 12010: 12011: 22013: 62014: 12015: 272016: 562017: 332018: 302019: 1272020: 1022021: 1002022: 1042023: 612024: 442025: 41
2007high 127 (2019) · low 0 (2007)2025

MAUDE reports naming product code HGI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20080—01
20090—01
20100—01
20110—02
20121—10
20130—06
20141—11
20150—027
20161—056
20170—033
20180—030
20190—3127
20200—0102
20211—7100
20220—0104
20230—061
20240—044
20250—041
20260—0—

What is it indicated for?

The loop electrodes are designed for the LEEP or LLETZ procedure, which is performed to remove a lesion of abnormal cells from the cervix. The loop electrode is aftached to an electrosurgical generator that emits an electrical current used to cut away the affected tissue, Following the removal of the cells in the affected area the ball electrode is used to seal the area and stop any bleeding that may have occurred. Some indications for use are: Cervical…

Read the full statement (111 words)

The loop electrodes are designed for the LEEP or LLETZ procedure, which is performed to remove a lesion of abnormal cells from the cervix. The loop electrode is aftached to an electrosurgical generator that emits an electrical current used to cut away the affected tissue, Following the removal of the cells in the affected area the ball electrode is used to seal the area and stop any bleeding that may have occurred.

Some indications for use are:

Cervical conizations

Large Loop Excision of the Transformation Zone

(LLETZ) in the Diagnosis and Treatment of some

Cetvical Intraepithelial Neoplasias (CIN) and

Dysplasias.

c. External Anogenital Lesions

d. Large Vaginal Intraepithelial Neoplasic (VAIN)

Lesions.

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K993777: Disposable and Reusable Ball and Loop Electrodes.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K993777

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026