510(k) Report

510(k) · Cleared

Cleared

Radiocameras System Head/Neck Application

K994355510(k) TraditionalCleared Mar 22, 200090-day reviewClass II21 CFR 892.5050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Surgical Navigation Technologies, Inc. · IYE Accelerator, Linear, Medical

Cleared on Mar 22, 2000 after a 90-day review. The FDA summary names no predicate by number. 4 later devices descend from it.

Decided
Mar 22, 2000
Review
90 days
Class
Class II
Product code
IYE
Recalls
None
Predicates
0

4 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2005: 1 descendant cleared2007: 1 descendant cleared2014: 1 descendant cleared2018: 1 descendant cleared200020052010201520202025
  1. This deviceK994355 Radiocameras System Head/Neck ApplicationSurgical Navigation Technologies, Inc. · 2000
  2. Descendant · cites it directly · 2 of its ownK071360 Optical Guidance PlatformVarian Medical Systems, Inc. · 2007 · Recalled
  3. Descendant · 2 generations on · 1 of its ownK142560 Varian Head FrameVarian Medical Systems, Inc. · 2014 · Recalled
  4. Descendant · 3 generations on · 0 of its ownK180586 Varian Head FrameVarian Medical Systems, Inc. · 2018
  5. Descendant · cites it directly · 0 of its ownK042875 NavigatorNomos Corp. · 2005

Most influential descendants

Showing 4 of 4 · See all
  • K071360Optical Guidance PlatformVarian Medical Systems, Inc. · 2007 · cites it directly2descendants
  • K142560Varian Head FrameVarian Medical Systems, Inc. · 2014 · 2 generations on1descendant
  • K180586Varian Head FrameVarian Medical Systems, Inc. · 2018 · 3 generations on0descendants
  • K042875NavigatorNomos Corp. · 2005 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K994355Radiocameras System Head/Neck ApplicationSurgical Navigation Technologies, Inc.2000—
+1K071360Optical Guidance PlatformVarian Medical Systems, Inc.20075
+2K142560Varian Head FrameVarian Medical Systems, Inc.20141
+3K180586Varian Head FrameVarian Medical Systems, Inc.2018—
+1K042875NavigatorNomos Corp.2005—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200510
200710
201410
201810
FIG. 1 — Lineage of K994355, 2000–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IYE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IYE device

  1. #1 K252977 Halcyon, Ethos Radiotherapy System (5.0)score 18.8 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

The FDA summary names no predicate by number.

What descends from it? (4)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K071360Optical Guidance PlatformVarian Medical Systems, Inc.20072
K042875NavigatorNomos Corp.20050

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K071360 (Varian Medical Systems, Inc., 2007) has gone furthest, with 2 descendants of its own.

How does its category compare?

All IYE devices

IYE Accelerator, Linear, Medical: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · IYE

12in 2025

2007: 232008: 142009: 202010: 232011: 112012: 282013: 182014: 202015: 202016: 212017: 232018: 212019: 192020: 202021: 192022: 122023: 182024: 92025: 122026 (partial year): 14
2007high 28 (2012) · low 9 (2024)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IYE

170in 2025

2007: 44 days median2008: 69 days median2009: 63 days median2010: 74 days median2011: 94 days median2012: 106 days median2013: 88 days median2014: 100 days median2015: 108 days median2016: 97 days median2017: 94 days median2018: 58 days median2019: 83 days median2020: 67 days median2021: 86 days median2022: 172 days median2023: 129 days median2024: 239 days median2025: 170 days median2026 (partial year): 120 days median
2007high 239 (2024) · low 44 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IYE

1in 2025

2007: 782008: 492009: 222010: 272011: 732012: 202013: 112014: 142015: 82016: 72017: 72018: 72019: 22020: 42021: 52022: 32023: 72024: 12025: 12026 (partial year): 4
2007high 78 (2007) · low 1 (2024)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · IYE

101in 2025

2007: 1552008: 1142009: 1742010: 2462011: 2802012: 1282013: 962014: 1242015: 1002016: 972017: 1252018: 852019: 912020: 742021: 682022: 662023: 1282024: 812025: 101
2007high 280 (2011) · low 66 (2022)2025

MAUDE reports naming product code IYE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007234478155
2008146949114
2009206322174
2010237427246
2011119473280
20122810620128
201318881196
20142010014124
2015201088100
20162197797
201723947125
20182158785
20191983291
20202067474
20211986568
202212172366
2023181297128
20249239181
2025121701101
2026141204—

What is it indicated for?

The RadioCameras™ Biteblock System Head/Neck Application is indicated for use with a photon linear accelerator to perform Stereotactic Radiosurgery or Radiotherapy on head and neck theraputic targets that lie outside the cranium. It provides precise positioning of the treatment target at the Linear Accelerator's isocenter.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K994355: Radiocameras System Head/Neck Application.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K994355

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026