Hologic, Inc. · MUE Full Field Digital, System, X-Ray, Mammographic

Approved on Sep 25, 2001 through premarket approval, which rests on the device’s own clinical evidence after a 196-day review. 2 later devices descend from it. It has been recalled 2 times.

Decided
Sep 25, 2001
Review
196 days
Class
Class II
Product code
MUE
Recalls
2

2 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2017: 1 descendant cleared2022: 1 descendant cleared200020052010201520202025
  1. This deviceP010017 Senoscan Full Field Digital Mammography SystemHologic, Inc. · 2001
  2. Descendant · cites it directly · 1 of its ownK172027 Adani MammoScanAdani · 2017
  3. Descendant · 2 generations on · 0 of its ownK210151 Digimamo DVmi Tecnologias Ltda · 2022

Most influential descendants

Showing 2 of 2 · See all
  • K172027Adani MammoScanAdani · 2017 · cites it directly1descendant
  • K210151Digimamo DVmi Tecnologias Ltda · 2022 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)P010017Senoscan Full Field Digital Mammography SystemHologic, Inc.2001—
+1K172027Adani MammoScanAdani2017—
+2K210151Digimamo DVmi Tecnologias Ltda2022—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201710
202210
FIG. 1 — Lineage of P010017, 2001–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA PMA database (decision fields and supplements), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MUE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MUE device

  1. #1 K253678 MAMMOMAT B.brilliant (11372950)score 13.6 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

Does it have a predicate?

PMA decisions do not claim a predicate device.

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K172027Adani MammoScanAdani20171

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
May 21, 2004Not classifiedZ-1094-04OtherExisting software may allow Image data to be truncated in the margin of the breast on processed patient images.
Apr 12, 2004Not classifiedZ-0939-04OtherX-ray tube may overheat after high usage because of mis-wired thermal switch circuit.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K172027 (Adani, 2017) has gone furthest, with 1 descendant of its own.

How does its category compare?

All MUE devices

MUE Full Field Digital, System, X-Ray, Mammographic: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MUE

3in 2025

2007: 62008: 52009: 82010: 102011: 102012: 42013: 72014: 12015: 12016: 12017: 82018: 22019: 22020: 42021: 42022: 32023: 12024: 12025: 32026 (partial year): 4
2007high 10 (2010) · low 1 (2014)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MUE

255in 2025

2011: 192 days median2012: 123 days median2013: 207 days median2017: 95 days median2020: 188 days median2021: 164 days median2022: 404 days median2025: 255 days median2026 (partial year): 185 days median
2007high 404 (2022) · low 95 (2017)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MUE

4in 2025

2008: 12009: 12010: 22011: 52014: 22017: 62018: 12019: 12023: 12025: 42026 (partial year): 1
2007high 6 (2017) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MUE

40in 2025

2008: 42009: 32010: 22011: 102012: 62013: 112014: 72015: 62016: 192017: 1152018: 1452019: 802020: 492021: 252022: 362023: 292024: 332025: 40
2007high 145 (2018) · low 0 (2007)2025

MAUDE reports naming product code MUE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20076—00
20085—14
20098—13
201010—22
201110192510
2012412306
20137207011
20141—27
20151—06
20161—019
20178956115
20182—1145
20192—180
20204188049
20214164025
20223404036
20231—129
20241—033
20253255440
202641851—
Cite this page

510(k) Report. “P010017: Senoscan Full Field Digital Mammography System.” Lineage record from FDA PMA data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/P010017

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026