510(k) Report

PMA · Approved

Recalled · Class II · 2021

Proact Adjustable Continence Therapy for Men

P130018PMAApproved Nov 24, 2015890-day reviewClass III21 CFR 876.5280Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Uromedica, Inc. · EZY Device, Incontinence, Mechanical/Hydraulic

Approved on Nov 24, 2015 through premarket approval, which rests on the device’s own clinical evidence after an 890-day review. It has been recalled 2 times.

Decided
Nov 24, 2015
Review
890 days
Class
Class III
Product code
EZY
Recalls
2

PMA approvals rest on their own clinical evidence and do not claim a predicate, so this family tree starts here.

P130018 has 6 supplements since 2016: changes to the approved device, its labelling or its manufacturing, each approved separately.

PMA supplements approved per year

2016: 12021: 12025: 22026: 2
2016high 2 (2025) · low 0 (2017)2026
View FIG. 1 as a table
YearSupplements approved
20161
20211
20252
20262
FIG. 1 — Supplements to P130018, 2016–2026Source: FDA PMA database

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA PMA database (decision fields and supplements), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in EZY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

Does it have a predicate?

PMA decisions do not claim a predicate device.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Nov 22, 2021Class IIZ-0458-2022Nonconforming Material/ComponentThe U-channel sheaths may cause damage to ProACT implant devices when the devices are passed through the sheath during a ProACT implantation procedure.
Apr 10, 2019Class IIZ-1808-2020Nonconforming Material/ComponentPotential issue with the manufacture and inspection of U-channel sheaths in Implantation Instruments Sets. Affected U-channel sheaths may be more likely to cause damage to ProACT implant devices when passes through the sheaths.

No ancestor or descendant has a Class I recall.

How does its category compare?

All EZY devices

EZY Device, Incontinence, Mechanical/Hydraulic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.

FDA decisions per year · EZY

6in 2025

2007: 62008: 62009: 72010: 62011: 42012: 82013: 22014: 42015: 92016: 142017: 122018: 122019: 102020: 102021: 32022: 62023: 42024: 32025: 62026 (partial year): 4
2007high 14 (2016) · low 2 (2013)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · EZY

Too few EZY 510(k)s in any year since 2007 to give a median.

Recalls per year · EZY

2in 2024

2011: 12021: 12024: 2
2007high 2 (2024) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · EZY

2,066in 2025

2007: 72008: 22009: 142010: 252011: 262012: 232013: 222014: 92015: 132016: 62017: 92018: 8732019: 2,7532020: 1,7432021: 1,6972022: 1,5532023: 1,7782024: 2,1102025: 2,066
2007high 2,753 (2019) · low 2 (2008)2025

MAUDE reports naming product code EZY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20076—07
20086—02
20097—014
20106—025
20114—126
20128—023
20132—022
20144—09
20159—013
201614—06
201712—09
201812—0873
201910—02,753
202010—01,743
20213—11,697
20226—01,553
20234—01,778
20243—22,110
20256—02,066
20264—0—
Cite this page

510(k) Report. “P130018: Proact Adjustable Continence Therapy for Men.” Lineage record from FDA PMA data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/P130018

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Page last updated Nov 3, 2026