510(k) Report

PMA · Approved

Recalled · Class II · 2023

Alinity m HCV

P190025PMAApproved Mar 23, 2020175-day reviewClass II21 CFR 866.3170Recalls 5

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Abbott Molecular, Inc. · MZP Assay, Hybridization And/Or Nucleic Acid Amplification For Detection Of Hepatitis C Rna,Hepatitis C Virus

Approved on Mar 23, 2020 through premarket approval, which rests on the device’s own clinical evidence after a 175-day review. 1 later device descends from it. It has been recalled 5 times.

Decided
Mar 23, 2020
Review
175 days
Class
Class II
Product code
MZP
Recalls
5

1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2025: 1 descendant cleared2020202220242026
  1. This deviceP190025 Alinity m HCVAbbott Molecular, Inc. · 2020
  2. Descendant · cites it directly · 0 of its ownK252102 Alinity m HCVAbbott Molecular, Inc. · 2025

Most influential descendants

Showing 1 of 1 · See all
  • K252102Alinity m HCVAbbott Molecular, Inc. · 2025 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)P190025Alinity m HCVAbbott Molecular, Inc.2020—
+1K252102Alinity m HCVAbbott Molecular, Inc.2025—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202510
FIG. 1 — Lineage of P190025, 2020–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA PMA database (decision fields and supplements), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MZP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MZP device

  1. #1 K252484 cobas HCVscore 10.6 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

Does it have a predicate?

PMA decisions do not claim a predicate device.

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K252102Alinity m HCVAbbott Molecular, Inc.20250

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Oct 30, 2023Class IIZ-0407-2024OtherAbbott has received reports of an increase in reactive negative controls and false positive results in patient samples when using the Identified Lots of Alinity m HCV AMP Kit.
Dec 9, 2022Class IIZ-1009-2023Under Investigation by firmThe firm identified the following three potential issues which may have impacted ADUs installed on distributed Alinity m Systems. 1. Systems which had their ADUs serviced may have an incorrect board value (calibration data file)…
Nov 11, 2022Class IIZ-1349-2023Under Investigation by firmThe instrument was found to be installed without plunger assemblies in the clamp bar for an Amplification Detection Unit. After correction of the issue, the instrument was returned for use without calibration. This would result in a…
Jul 19, 2022Class IIZ-1518-2022Nonconforming Material/ComponentIncorrect optical calibration
Dec 6, 2021Class IIZ-0463-2022Software designThere is an issue with the installation of updated camera firmware on the system.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K252102 (Abbott Molecular, Inc., 2025) has gone furthest, with 0 descendants of its own.

How does its category compare?

All MZP devices

MZP Assay, Hybridization And/Or Nucleic Acid Amplification For Detection Of Hepatitis C Rna,Hepatitis C Virus: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · MZP

2in 2025

2007: 52008: 122009: 112010: 192011: 202012: 172013: 242014: 122015: 122016: 212017: 152018: 302019: 352020: 182021: 82022: 12024: 12025: 2
2007high 35 (2019) · low 0 (2023)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MZP

Too few MZP 510(k)s in any year since 2007 to give a median.

Recalls per year · MZP

1in 2023

2007: 12011: 22021: 42023: 1
2007high 4 (2021) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MZP

12in 2025

2008: 62009: 122010: 112011: 442012: 262013: 362014: 132015: 12016: 122017: 52018: 42019: 52020: 12021: 12022: 12023: 12024: 22025: 12
2007high 44 (2011) · low 0 (2007)2025

MAUDE reports naming product code MZP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20075—10
200812—06
200911—012
201019—011
201120—244
201217—026
201324—036
201412—013
201512—01
201621—012
201715—05
201830—04
201935—05
202018—01
20218—41
20221—01
20230—11
20241—02
20252—012
20260—0—
Cite this page

510(k) Report. “P190025: Alinity m HCV.” Lineage record from FDA PMA data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/P190025

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026