510(k) Report

510(k) · Cleared

Cleared

Spiral Radius Rodding System

K000009510(k) AbbreviatedCleared Mar 10, 200067-day reviewClass II21 CFR 888.3060

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

United States Surgical, A Division of Tyco Healthc · KWQ Appliance, Fixation, Spinal Intervertebral Body

Cleared on Mar 10, 2000 as substantially equivalent to K992784 (United States Surgical, A Division of Tyco Healthc, 1999) after a 67-day review. Its family tree reaches back 4 generations to 1997. 1 later device descends from it.

Decided
Mar 10, 2000
Review
67 days
Class
Class II
Product code
KWQ
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K970635 (1997). 6 ancestors in all. 1 later device descends from it, 1 citing it directly.

  1. Root · 4 generations backK970635 Titanium Spinal Rod SystemSmith & Nephew, Inc., Orthopaedic Div. · 1997
  2. 3 generations backK974213 Aurora Titanium Spinal Rod SystemUnited States Surgical, A Division of Tyco Healthc · 1998
  3. 2 generations backK983197 Surgical Dynamics Rodding System (Previously Known as the Aurora…United States Surgical, A Division of Tyco Healthc · 1998
  4. 1 generation backK992784 Next Generation Rodding SystemUnited States Surgical, A Division of Tyco Healthc · 1999
  5. This deviceK000009 Spiral Radius Rodding SystemUnited States Surgical, A Division of Tyco Healthc · 2000
  6. Descendant · cites it directly · 0 of its ownK012273 Spiral Radius 90-D SST SystemUnited States Surgical, A Division of Tyco Healthc · 2001

Most influential descendants

Showing 1 of 1 · See all
  • K012273Spiral Radius 90-D SST SystemUnited States Surgical, A Division of Tyco Healthc · 2001 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K970635Titanium Spinal Rod SystemSmith & Nephew, Inc., Orthopaedic Div.1997—
−3K974213Aurora Titanium Spinal Rod SystemUnited States Surgical, A Division of Tyco Healthc1998—
−2K983197Surgical Dynamics Rodding System (Previously Known as the Aurora Titanium…United States Surgical, A Division of Tyco Healthc1998—
−1K992784Next Generation Rodding SystemUnited States Surgical, A Division of Tyco Healthc1999—
0 (this device)K000009Spiral Radius Rodding SystemUnited States Surgical, A Division of Tyco Healthc2000—
+1K012273Spiral Radius 90-D SST SystemUnited States Surgical, A Division of Tyco Healthc2001—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199820

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200110
FIG. 1 — Lineage of K000009, 1997–2001Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KWQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KWQ device

  1. #1 K233640 Segmental Plating System (SPS);IdentiTi SPS…score 21.9 · 31 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K992784Next Generation Rodding System
Summary page 1
…Titanium Spinal Rod System PROPRIETARY NAME: Spiral Radius Rodding System PREDICATE DEVICES: USS's Spiral Radius Rodding System - K992784 INTENDED USE: The components of the Spiral Radius Rodding System are indicated for spinal fi…
United States Surgical, A Division of Tyco Healthc1999—

Also cleared against K992784: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K012273Spiral Radius 90-D SST SystemUnited States Surgical, A Division of Tyco Healthc20010

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 3 years and passes through 2 companies; a new generation was cleared every 9 months on median.
  • None of the 6 ancestors has a recall.
  • Of its descendants, K012273 (United States Surgical, A Division of Tyco Healthc, 2001) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K992784.

How does its category compare?

All KWQ devices

KWQ Appliance, Fixation, Spinal Intervertebral Body: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KWQ

7in 2025

2007: 272008: 322009: 232010: 232011: 222012: 262013: 222014: 172015: 252016: 152017: 202018: 222019: 262020: 262021: 172022: 182023: 162024: 172025: 72026 (partial year): 10
2007high 32 (2008) · low 7 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KWQ

64in 2025

2007: 101 days median2008: 70 days median2009: 90 days median2010: 104 days median2011: 95 days median2012: 90 days median2013: 88 days median2014: 124 days median2015: 102 days median2016: 121 days median2017: 67 days median2018: 95 days median2019: 81 days median2020: 55 days median2021: 59 days median2022: 85 days median2023: 59 days median2024: 64 days median2025: 64 days median2026 (partial year): 76 days median
2007high 124 (2014) · low 55 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KWQ

1in 2018

2007: 22008: 332009: 352010: 22011: 52012: 72013: 62015: 22016: 92017: 82018: 1
2007high 35 (2009) · low 0 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KWQ

248in 2025

2007: 2882008: 3482009: 3552010: 6912011: 4152012: 5442013: 7962014: 5462015: 5622016: 5022017: 4922018: 3412019: 2982020: 4002021: 5912022: 3922023: 3202024: 4192025: 248
2007high 796 (2013) · low 248 (2025)2025

MAUDE reports naming product code KWQ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007271012288
2008327033348
2009239035355
2010231042691
201122955415
201226907544
201322886796
2014171240546
2015251022562
2016151219502
201720678492
201822951341
201926810298
202026550400
202117590591
202218850392
202316590320
202417640419
20257640248
202610760—

What is it indicated for?

The components of the Spiral Radius Rodding System are indicated for spinal fixation. When used as an ante rolateraI/anterior system consisting of rods and screws, the levels of attachment are the lumbar, thoracic and cervical spine. The points of attachment and methods are screw fixation to the anterolateral vertebral bodies of the lumbar and thoracic spine (T6-L5) and the anterior vertebral bodies of the cervical spine. The indications are degenerative…

Read the full statement (356 words)

The components of the Spiral Radius Rodding System are indicated for spinal fixation.

When used as an ante rolateraI/anterior system consisting of rods and screws, the levels of attachment are the lumbar, thoracic and cervical spine. The points of attachment and methods are screw fixation to the anterolateral vertebral bodies of the lumbar and thoracic spine (T6-L5) and the anterior vertebral bodies of the cervical spine. The indications are degenerative disc disease defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies, spondylolisthesis, fracture, spinal stenosis, deformities (i.e., scoliosis, kyphosis, lordosis), tumor, pseudoarthrosis, or failed previous fusion (pseudoarthrosis).

When used as a nonpedicle posterior system consisting of hooks, crosslinks and sacral/iliac screws the levels of attachments are the lumbar, thoracic and cervical spine and sacrum and ilium. Intended uses include hook and sacral screw fixation to the lumbar spine, noncervical spine and to the T1-S1 spine-, and hook and sacralfiliac screw fixation to the noncervical spine. The indications are degenerative disc disease defined as back pain of discogenic origin with degenerative of the disc confirmed by history and radiographic studies, spondylolisthesis, fracture, spinal stenosis, deformities (i.e., scoliosis, kyphosis, lordosis), tumors, pseudoarthrosis, or failed previous fusion (pseudoarthrosis).

When used as a pedicle screw system, in the non-cervical spine of skeletally mature patients, the Spiral Radius Rodding System is indicated for patients: (a) having severe spondylolisthesis (Grades 3 and 4) at the L5-S1 joint; (b) who are receiving fusions using autogenous bone graft only; (c) who are having the device fixed or attached to the lumbar and sacral spine (L3 and below); and (d) who are having the device removed after the development of solid fusion mass.

In addition, when used as a pedicle screw system, in the non-cervical spine of skeletally mature patients, the Spiral Radius Rodding System is intended to provide immobilization and stabilization of spinal segments, as an adjunct to fusion, in the treatment of the following acute and chronic instabilities of the thoracic, lumbar, and sacral spine: degenerative spondylolisthesis with objective evidence of neurologic impairment, fracture, dislocation, scoiiosis, kyphosis, spinal tumor, and failed previous fusion (pseudoarthrosis).

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K000009: Spiral Radius Rodding System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K000009

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026