510(k) Report

510(k) · Cleared

Cleared

Modification to Intuitive Surgical Stereo View Endoscopic System

K001666510(k) TraditionalCleared Aug 24, 200085-day reviewClass II21 CFR 876.1500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Intuitive Surgical, Inc. · GCJ Laparoscope, General & Plastic Surgery

Cleared on Aug 24, 2000 after an 85-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 5 later devices descend from it.

Decided
Aug 24, 2000
Review
85 days
Class
Class II
Product code
GCJ
Recalls
None
Predicates
0

5 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2002: 1 descendant cleared2008: 1 descendant cleared2019: 1 descendant cleared2017: 1 descendant cleared2024: 1 descendant cleared200020052010201520202025
  1. This deviceK001666 Modification to Intuitive Surgical Stereo View Endoscopic SystemIntuitive Surgical, Inc. · 2000
  2. Descendant · cites it directly · 3 of its ownK080155 Modification to:Intuitive Surgical Stereo View Endoscopic SystemIntuitive Surgical, Inc. · 2008
  3. Descendant · 2 generations on · 1 of its ownK191043 da Vinci Handheld CameraIntuitive Surgical, Inc. · 2019 · Recalled
  4. Descendant · 3 generations on · 0 of its ownK241913 da Vinci Handheld CameraIntuitive Surgical Operations, Inc. · 2024
  5. Descendant · 2 generations on · 0 of its ownK170641 da Vinci S/Si Endoscopes, da Vinci Xi EndoscopesIntuitive Surgical, Inc. · 2017
  6. Descendant · cites it directly · 0 of its ownK013952 Intuitive Surgical Stero View Endoscopic SystemIntuitive Surgical, Inc. · 2002

Most influential descendants

Showing 5 of 5 · See all
  • K080155Modification to:Intuitive Surgical Stereo View Endoscopic SystemIntuitive Surgical, Inc. · 2008 · cites it directly3descendants
  • K191043da Vinci Handheld CameraIntuitive Surgical, Inc. · 2019 · 2 generations on1descendant
  • K241913da Vinci Handheld CameraIntuitive Surgical Operations, Inc. · 2024 · 3 generations on0descendants
  • K170641da Vinci S/Si Endoscopes, da Vinci Xi EndoscopesIntuitive Surgical, Inc. · 2017 · 2 generations on0descendants
  • K013952Intuitive Surgical Stero View Endoscopic SystemIntuitive Surgical, Inc. · 2002 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K001666Modification to Intuitive Surgical Stereo View Endoscopic SystemIntuitive Surgical, Inc.2000—
+1K080155Modification to:Intuitive Surgical Stereo View Endoscopic SystemIntuitive Surgical, Inc.2008—
+2K191043da Vinci Handheld CameraIntuitive Surgical, Inc.20191
+3K241913da Vinci Handheld CameraIntuitive Surgical Operations, Inc.2024—
+2K170641da Vinci S/Si Endoscopes, da Vinci Xi EndoscopesIntuitive Surgical, Inc.2017—
+1K013952Intuitive Surgical Stero View Endoscopic SystemIntuitive Surgical, Inc.2002—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200210
200810
201710
201910
202410
FIG. 1 — Lineage of K001666, 2000–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GCJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GCJ device

  1. #1 K214046 780 nm 1688 4K Camera System, 780 nm L11 LED…score 21.4 · 21 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it? (5)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K080155Modification to:Intuitive Surgical Stereo View Endoscopic SystemIntuitive Surgical, Inc.20083
K013952Intuitive Surgical Stero View Endoscopic SystemIntuitive Surgical, Inc.20020

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K080155 (Intuitive Surgical, Inc., 2008) has gone furthest, with 3 descendants of its own.

How does its category compare?

All GCJ devices

GCJ Laparoscope, General & Plastic Surgery: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GCJ

21in 2025

2007: 182008: 192009: 212010: 242011: 152012: 172013: 152014: 192015: 262016: 272017: 202018: 212019: 152020: 282021: 182022: 202023: 312024: 292025: 212026 (partial year): 26
2007high 31 (2023) · low 15 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GCJ

108in 2025

2007: 42 days median2008: 73 days median2009: 85 days median2010: 122 days median2011: 113 days median2012: 88 days median2013: 93 days median2014: 90 days median2015: 76 days median2016: 99 days median2017: 77 days median2018: 88 days median2019: 60 days median2020: 61 days median2021: 116 days median2022: 103 days median2023: 109 days median2024: 90 days median2025: 108 days median2026 (partial year): 122 days median
2007high 122 (2010) · low 42 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GCJ

5in 2025

2007: 122008: 162009: 62010: 302011: 92012: 12013: 7, 1 Class I2014: 22016: 52017: 12018: 12022: 12023: 12025: 52026 (partial year): 1
2007high 30 (2010) · low 0 (2015)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · GCJ

5,860in 2025

2007: 1,6392008: 1,3192009: 1,9952010: 2,6572011: 2,1332012: 1,5262013: 1,5652014: 1,7142015: 1,7102016: 2,0802017: 3,4682018: 2,5622019: 2,5782020: 2,6182021: 3,4312022: 3,9452023: 6,0022024: 6,0472025: 5,860
2007high 6,047 (2024) · low 1,319 (2008)2025

MAUDE reports naming product code GCJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071842121,639
20081973161,319
2009218561,995
201024122302,657
20111511392,133
2012178811,526
201315937 (1)1,565
2014199021,714
2015267601,710
2016279952,080
2017207713,468
2018218812,562
2019156002,578
2020286102,618
20211811603,431
20222010313,945
20233110916,002
2024299006,047
20252110855,860
2026261221—
Cite this page

510(k) Report. “K001666: Modification to Intuitive Surgical Stereo View Endoscopic System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K001666

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026