510(k) · Cleared
ClearedModification to Centaur Spinal System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Howmedica Osteonics Corp. · KWQ Appliance, Fixation, Spinal Intervertebral Body
Cleared on Jul 19, 2000 after a 30-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 103 later devices descend from it.
- Decided
- Jul 19, 2000
- Review
- 30 days
- Class
- Class II
- Product code
- KWQ
- Recalls
- None
- Predicates
- 0
103 later devices descend from it, 4 citing it directly.
- This deviceK001844 Modification to Centaur Spinal SystemHowmedica Osteonics Corp. · 2000
- Descendant · cites it directly · 102 of its ownK073437 Thor Anterior Plating SystemStryker Spine · 2008 · Recalled
- Descendant · cites it directly · 101 of its ownK080773 Thor Anterior Plating SystemStryker Spine · 2008
- Descendant · 2 generations on · 73 of its ownK091253 Thoracolumbar Plate, Model 1208-41FXX, Lumber Plate, Model…K2m, Inc. · 2009
- Descendant · 3 generations on · 72 of its ownK131533 Cayman MI Plate SystemK2m, Inc. · 2013
- Descendant · 4 generations on · 52 of its ownK172941 CASCADIA Interbody SystemK2m · 2018
Showing 5 of 103 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 103 · See all- K073437Thor Anterior Plating SystemStryker Spine · 2008 · cites it directly102descendants
- K080773Thor Anterior Plating SystemStryker Spine · 2008 · cites it directly101descendants
- K091253Thoracolumbar Plate, Model 1208-41FXX, Lumber Plate, Model 1208-41FXXL, Sacral Plate…K2m, Inc. · 2009 · 2 generations on73descendants
- K131533Cayman MI Plate SystemK2m, Inc. · 2013 · 3 generations on72descendants
- K172941CASCADIA Interbody SystemK2m · 2018 · 4 generations on52descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K001844 | Modification to Centaur Spinal System | Howmedica Osteonics Corp. | 2000 | — |
| +1 | K073437 | Thor Anterior Plating System | Stryker Spine | 2008 | 31 |
| +1 | K080773 | Thor Anterior Plating System | Stryker Spine | 2008 | — |
| +2 | K091253 | Thoracolumbar Plate, Model 1208-41FXX, Lumber Plate, Model 1208-41FXXL, Sacral… | K2m, Inc. | 2009 | — |
| +3 | K131533 | Cayman MI Plate System | K2m, Inc. | 2013 | — |
| +4 | K172941 | CASCADIA Interbody System | K2m | 2018 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2008 | 2 | 0 |
| 2009 | 1 | 0 |
| 2013 | 1 | 0 |
| 2014 | 1 | 0 |
| 2015 | 1 | 0 |
| 2018 | 4 | 0 |
| 2019 | 7 | 0 |
| 2020 | 4 | 0 |
| 2021 | 6 | 0 |
| 2022 | 11 | 0 |
| 2023 | 20 | 0 |
| 2024 | 16 | 0 |
| 2025 | 13 | 0 |
| 2026 | 16 | 0 |
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KWQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KWQ device
- #1 K233640 Segmental Plating System (SPS);IdentiTi SPS…score 21.9 · 31 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it? (103)
See all 1034 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K073437 (Stryker Spine, 2008) has gone furthest, with 102 descendants of its own.
How does its category compare?
All KWQ devicesKWQ Appliance, Fixation, Spinal Intervertebral Body: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · KWQ
7in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · KWQ
64in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KWQ
1in 2018
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KWQ
248in 2025
MAUDE reports naming product code KWQ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 27 | 101 | 2 | 288 |
| 2008 | 32 | 70 | 33 | 348 |
| 2009 | 23 | 90 | 35 | 355 |
| 2010 | 23 | 104 | 2 | 691 |
| 2011 | 22 | 95 | 5 | 415 |
| 2012 | 26 | 90 | 7 | 544 |
| 2013 | 22 | 88 | 6 | 796 |
| 2014 | 17 | 124 | 0 | 546 |
| 2015 | 25 | 102 | 2 | 562 |
| 2016 | 15 | 121 | 9 | 502 |
| 2017 | 20 | 67 | 8 | 492 |
| 2018 | 22 | 95 | 1 | 341 |
| 2019 | 26 | 81 | 0 | 298 |
| 2020 | 26 | 55 | 0 | 400 |
| 2021 | 17 | 59 | 0 | 591 |
| 2022 | 18 | 85 | 0 | 392 |
| 2023 | 16 | 59 | 0 | 320 |
| 2024 | 17 | 64 | 0 | 419 |
| 2025 | 7 | 64 | 0 | 248 |
| 2026 | 10 | 76 | 0 | — |
https://510kreport.com/device/K001844 · printed Nov 5, 2026
Cite this page
510(k) Report. “K001844: Modification to Centaur Spinal System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K001844
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026