510(k) Report

510(k) · Cleared

Cleared

Automated Core Biopsy Device

K011270510(k) TraditionalCleared Jun 22, 200157-day reviewClass II21 CFR 876.1075

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Promex, Inc. · FCG Biopsy Needle

Cleared on Jun 22, 2001 after a 57-day review. FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known. 6 later devices descend from it.

Decided
Jun 22, 2001
Review
57 days
Class
Class II
Product code
FCG
Recalls
None
Predicates
0

6 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2011: 1 descendant cleared2005: 1 descendant cleared2014: 1 descendant cleared2016: 1 descendant cleared2021: 1 descendant cleared2026: 1 descendant cleared200020052010201520202025
  1. This deviceK011270 Automated Core Biopsy DevicePromex, Inc. · 2001
  2. Descendant · cites it directly · 4 of its ownK111765 Full Core Biopsy SystemPromex Technologies, LLC · 2011
  3. Descendant · 2 generations on · 3 of its ownK140137 Safety Biopsy Needle SystemPfm Medical, Inc. · 2014
  4. Descendant · 3 generations on · 2 of its ownK160423 Perineologic Access NeedleCorbin Clinical Resources, LLC · 2016
  5. Descendant · 4 generations on · 1 of its ownK210946 Promisemed Automatic Biopsy Needles, Promisemed Co-Axial Biopsy…Promisemed Hangzhou Meditech Co., Ltd. · 2021
  6. Descendant · 5 generations on · 0 of its ownK261196 Promisemed VeriEcto Automatic Biopsy NeedlesPromisemed Hangzhou Meditech Co., Ltd. · 2026

Showing 5 of 6 descendants. See all descendants

Descendants cleared per year

2005: 12011: 12014: 12016: 12021: 12026: 1
2005high 1 (2005) · low 0 (2006)2026

Most influential descendants

Showing 5 of 6 · See all
  • K111765Full Core Biopsy SystemPromex Technologies, LLC · 2011 · cites it directly4descendants
  • K140137Safety Biopsy Needle SystemPfm Medical, Inc. · 2014 · 2 generations on3descendants
  • K160423Perineologic Access NeedleCorbin Clinical Resources, LLC · 2016 · 3 generations on2descendants
  • K210946Promisemed Automatic Biopsy Needles, Promisemed Co-Axial Biopsy Devices, Promisemed…Promisemed Hangzhou Meditech Co., Ltd. · 2021 · 4 generations on1descendant
  • K261196Promisemed VeriEcto Automatic Biopsy NeedlesPromisemed Hangzhou Meditech Co., Ltd. · 2026 · 5 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K011270Automated Core Biopsy DevicePromex, Inc.2001—
+1K111765Full Core Biopsy SystemPromex Technologies, LLC2011—
+2K140137Safety Biopsy Needle SystemPfm Medical, Inc.2014—
+3K160423Perineologic Access NeedleCorbin Clinical Resources, LLC2016—
+4K210946Promisemed Automatic Biopsy Needles, Promisemed Co-Axial Biopsy Devices…Promisemed Hangzhou Meditech Co., Ltd.2021—
+5K261196Promisemed VeriEcto Automatic Biopsy NeedlesPromisemed Hangzhou Meditech Co., Ltd.2026—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200510
201110
201410
201610
202110
202610
FIG. 1 — Lineage of K011270, 2001–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FCG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FCG device

  1. #1 K250994 ClearTip FNA and FNB Typesscore 13.2 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known.

What descends from it? (6)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K111765Full Core Biopsy SystemPromex Technologies, LLC20114
K052435Pneumrx Family of Biopsy Needles and KitsPneumrx, Inc.20050

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K111765 (Promex Technologies, LLC, 2011) has gone furthest, with 4 descendants of its own.

How does its category compare?

All FCG devices

FCG Biopsy Needle: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FCG

2in 2025

2007: 42008: 12009: 42010: 32011: 12013: 12014: 52015: 42016: 32017: 32018: 62020: 12021: 12022: 22023: 42024: 12025: 2
2007high 6 (2018) · low 0 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FCG

82in 2023

2007: 32 days median2009: 87 days median2010: 18 days median2014: 88 days median2015: 91 days median2016: 63 days median2017: 166 days median2018: 140 days median2023: 82 days median
2007high 166 (2017) · low 18 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FCG

5in 2021

2008: 192009: 52010: 42011: 22021: 5
2007high 19 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FCG

632in 2025

2007: 112008: 1152009: 2702010: 732011: 712012: 1072013: 1302014: 1542015: 1242016: 1912017: 2732018: 2822019: 2292020: 2402021: 2902022: 3022023: 4282024: 4462025: 632
2007high 632 (2025) · low 11 (2007)2025

MAUDE reports naming product code FCG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007432011
20081—19115
20094875270
2010318473
20111—271
20120—0107
20131—0130
20145880154
20154910124
20163630191
201731660273
201861400282
20190—0229
20201—0240
20211—5290
20222—0302
20234820428
20241—0446
20252—0632
20260—0—
Cite this page

510(k) Report. “K011270: Automated Core Biopsy Device.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K011270

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026