510(k) · Cleared
ClearedSpine Scope, Model 2180
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Clarus Medical, LLC · HRX Arthroscope
Cleared on Dec 13, 2001 after a 216-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 40 later devices descend from it.
- Decided
- Dec 13, 2001
- Review
- 216 days
- Class
- Class II
- Product code
- HRX
- Recalls
- None
- Predicates
- 0
40 later devices descend from it, 3 citing it directly.
- This deviceK011454 Spine Scope, Model 2180Clarus Medical, LLC · 2001
- Descendant · cites it directly · 20 of its ownK082841 Spinal ForaminoscopeBlazejewski Medi-Tech GmbH · 2009
- Descendant · cites it directly · 18 of its ownK040424 Laser Endoscopic Decompression Kit, Model 1100, and Percutaneous…Clarus Medical, LLC · 2004 · Recalled
- Descendant · cites it directly · 17 of its ownK040919 Nucleotome Probe Set, Model 21200Clarus Medical, LLC · 2004 · Recalled
- Descendant · 2 generations on · 14 of its ownK130778 Discoscopes, Cervical EndoscopesRz Medizintechnik GmbH · 2014
- Descendant · 2 generations on · 14 of its ownK062038 X-Sten Mild Tool Kit, Model MTK-0001X-Sten Corp. · 2006
Showing 5 of 40 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 40 · See all- K082841Spinal ForaminoscopeBlazejewski Medi-Tech GmbH · 2009 · cites it directly20descendants
- K040424Laser Endoscopic Decompression Kit, Model 1100, and Percutaneous Discectomy Kit, Model…Clarus Medical, LLC · 2004 · cites it directly18descendants
- K040919Nucleotome Probe Set, Model 21200Clarus Medical, LLC · 2004 · cites it directly17descendants
- K130778Discoscopes, Cervical EndoscopesRz Medizintechnik GmbH · 2014 · 2 generations on14descendants
- K062038X-Sten Mild Tool Kit, Model MTK-0001X-Sten Corp. · 2006 · 2 generations on14descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K011454 | Spine Scope, Model 2180 | Clarus Medical, LLC | 2001 | — |
| +1 | K082841 | Spinal Foraminoscope | Blazejewski Medi-Tech GmbH | 2009 | — |
| +1 | K040424 | Laser Endoscopic Decompression Kit, Model 1100, and Percutaneous Discectomy… | Clarus Medical, LLC | 2004 | 1 |
| +1 | K040919 | Nucleotome Probe Set, Model 21200 | Clarus Medical, LLC | 2004 | 1 |
| +2 | K130778 | Discoscopes, Cervical Endoscopes | Rz Medizintechnik GmbH | 2014 | — |
| +2 | K062038 | X-Sten Mild Tool Kit, Model MTK-0001 | X-Sten Corp. | 2006 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2004 | 2 | 0 |
| 2006 | 1 | 0 |
| 2009 | 3 | 0 |
| 2010 | 1 | 0 |
| 2012 | 1 | 0 |
| 2013 | 1 | 0 |
| 2014 | 2 | 0 |
| 2018 | 3 | 0 |
| 2019 | 1 | 0 |
| 2020 | 1 | 0 |
| 2021 | 1 | 0 |
| 2023 | 1 | 0 |
| 2024 | 5 | 0 |
| 2025 | 10 | 0 |
| 2026 | 7 | 0 |
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HRX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HRX device
- #1 K260203 Fule Vertebroplasty Balloon Catheterscore 14.9 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA has not posted a summary or statement for it, so its predicates are not known.
What descends from it? (40)
See all 403 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K082841 (Blazejewski Medi-Tech GmbH, 2009) has gone furthest, with 20 descendants of its own.
How does its category compare?
All HRX devicesHRX Arthroscope: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · HRX
9in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · HRX
107in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HRX
1in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HRX
2,076in 2025
MAUDE reports naming product code HRX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 7 | 89 | 3 | 421 |
| 2008 | 9 | 115 | 13 | 441 |
| 2009 | 11 | 139 | 23 | 558 |
| 2010 | 9 | 114 | 12 | 612 |
| 2011 | 3 | 84 | 6 | 631 |
| 2012 | 11 | 102 | 0 | 778 |
| 2013 | 12 | 90 | 4 | 678 |
| 2014 | 9 | 140 | 0 | 802 |
| 2015 | 4 | 132 | 7 | 763 |
| 2016 | 8 | 89 | 0 | 469 |
| 2017 | 4 | 97 | 0 | 934 |
| 2018 | 12 | 101 | 1 | 1,581 |
| 2019 | 12 | 45 | 0 | 1,676 |
| 2020 | 7 | 141 | 0 | 1,706 |
| 2021 | 7 | 57 | 3 | 1,908 |
| 2022 | 3 | 89 | 0 | 1,406 |
| 2023 | 4 | 249 | 0 | 1,852 |
| 2024 | 6 | 110 | 1 | 2,427 |
| 2025 | 9 | 107 | 0 | 2,076 |
| 2026 | 7 | 217 | 0 | — |
https://510kreport.com/device/K011454 · printed Nov 6, 2026
Cite this page
510(k) Report. “K011454: Spine Scope, Model 2180.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K011454
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026